[IP address]

[IP address]

When "Off" is selected for "DHCP", enter an IP address. Enter 4 units from the decimal numbers (0-255). Default: 192.168.0.250

[Subnet mask]

Enter a subnet mask according to the network environment when "Off" is selected for "DHCP". Enter 4 units from the decimal numbers (0-255).

Default: 255.255.255.0

[Default gateway]

Enter the IP address of the gateway according to the net- work environment when "Off" is selected for "DHCP". Enter 4 units from the decimal numbers (0-255).

Default: 192.168.0.1

[Line speed]

Specify the line speed for data transmission. Auto: Line speed will be applied automatically. 10M-Half:10 Mbps half-duplex

10M-Full:10 Mbps full-duplex

100M-Half:100 Mbps half-duplex

100M-Full: 100 Mbps full-duplexDefault: Auto

Maintenance port

The setting for the maintenance port behind the front cover of the recorder is configured.

This setting is required to maintain and support the recorder from a PC connected via a network using the maintenance port.

[IP address]

When "Off" is selected for "DHCP", enter an IP address. Enter 4 units from the decimal numbers (0-255). Default: 192.168.2.250

[Subnet mask]

Enter a subnet mask according to the network environment when "Off" is selected for "DHCP". Enter 4 units from the decimal numbers (0-255).

Default: 255.255.255.0

Important:

The settings of "Network Port" and "Maintenance Port" should be on a different subnet.

[Line speed]

Displays the line speed for data transmission. It is impossible to change the setting value.