8: Network Settings

 

 

 

 

Network Interface

Description

 

Settings (continued)

 

 

Hostname

Enter the hostname for the interface. It must begin with a letter or number,

 

 

continue with a sequence of letters, numbers, or hyphens, and end with a letter

 

 

or number.

 

 

Note: This setting will take effect immediately, but will not register the

 

 

hostname with a DNS server until the next reboot.

 

 

 

 

Domain

Enter the domain name suffix for the interface.

 

 

Note: This setting will be used when either Static IP or Auto IP is active, or if

 

 

DHCP/BOOTP is active and no Domain Suffix was acquired from the server.

 

 

 

 

DHCP Client ID

Enter the ID if the DHCP server requires a DHCP Client ID option. The DHCP

 

 

server’s lease table shows IP addresses and MAC addresses for devices. The

 

 

lease table shows the Client ID, in hexadecimal notation, instead of the xSenso

 

 

MAC address.

 

 

 

 

Primary DNS

Enter the IP address of the primary Domain Name Server.

 

 

Note: This setting will be used when either Static IP or Auto IP is active, or if

 

 

DHCP/BOOTP is active and no DNS server was acquired from the server.

 

 

 

 

Secondary DNS

Enter the IP address of the secondary Domain Name Server.

 

 

Note: This setting will be used when either Static IP or Auto IP is active, or if

 

 

DHCP/BOOTP is active and no DNS server was acquired from the server.

 

 

 

 

MTU

When DHCP is enabled, the MTU size is (usually) provided with the IP address.

 

 

When not provided by the DHCP server, or using a static configuration, this

 

 

value is used. The MTU size can be from 576 to 1500 bytes, the default being

 

 

1500 bytes.

 

 

 

To Configure Network Interface Settings

Using Web Manager

To modify Ethernet (eth0) settings, go to the Admin tab/page, go to the Admin tab/page, click Network on the menu and select Network 1 -> Interface -> Configuration.

Using the CLI

To enter the eth0 command level: enable -> config -> if 1

Using XML

Include in your file: <configgroup name="interface" instance="eth0">

To View Network Interface Status

Using Web Manager

In Network Interface Status, you can view both the current operational settings as well as the settings that would take affect upon a device reboot.

To view Ethernet (eth0) Status, go to the Admin tab/page and click Network on the menu and select Network 1 -> Interface -> Status.

xSenso User Guide

51

Page 51
Image 51
Lantronix XSENSO 21R2 manual To Configure Network Interface Settings, To View Network Interface Status, Network Settings

XSENSO 2100, XSENSO 21A2, XSENSO 21R2 specifications

Lantronix, a leader in secure communications and IoT solutions, offers a range of innovative products that cater to various industrial and commercial needs. Among their impressive lineup are the XSENSO 21R2, XSENSO 21A2, and XSENSO 2100 devices, each designed for remote monitoring and control applications that require reliability and versatility.

The XSENSO 21R2 is a powerful device focused on advanced sensor management. It features multiple analog and digital inputs, enabling users to monitor a wide variety of environmental parameters such as temperature, humidity, and pressure. This model excels in applications requiring real-time data collection and analysis. Its robust construction ensures high performance in challenging environments, making it ideal for industrial settings. The XSENSO 21R2 also incorporates cloud connectivity options, allowing for seamless data transfer and integration with existing IoT infrastructures.

Similarly, the XSENSO 21A2 is designed for users who prioritize ease of use along with functionality. This device is equipped with a user-friendly interface that simplifies configuration and monitoring. It supports various communication protocols, ensuring compatibility with different systems and applications. The XSENSO 21A2 boasts a compact design, suitable for space-constrained installations, and provides options for local and remote access to data, enhancing user flexibility.

The XSENSO 2100 stands out with its high-performance processing capabilities, making it suitable for complex monitoring tasks. Its enhanced computing power allows it to run sophisticated analytics directly on the device, thereby reducing latency and bandwidth consumption. The XSENSO 2100 is especially useful in scenarios that require extensive data processing at the edge, such as predictive maintenance and machine learning applications. It is equipped with advanced security features, ensuring that sensitive data remains protected during transmission and storage.

All three models embody Lantronix's commitment to innovation, incorporating the latest technologies such as wireless connectivity options, cloud integration, and support for various industry standards. Their scalability makes them suitable for projects of all sizes, from small businesses to large enterprises. These devices not only enhance operational efficiency but also empower businesses to make data-driven decisions, ultimately leading to improved performance and cost savings. With Lantronix’s XSENSO devices, organizations can take a significant step towards realizing their IoT aspirations.