|
| 13: Action Settings |
|
|
|
| Make Connection | Description |
| Settings (continued) |
|
| SSH Username | Specify the SSH Client User for the SSH outgoing connection if the SSH protocol |
|
| is selected for this connection. You may select from the |
|
| existing users or you may enter a new user name. This configuration field is only |
|
| available if the SSH protocol is selected. |
|
|
|
| AES Encrypt Key | Enter an AES encryption key to encrypt outgoing data and select Hexadecimal |
|
| or Text. This configuration field is only available if either TCP AES or UDP AES |
|
| protocol is selected. |
|
|
|
| AES Decrypt Key | Enter an AES decryption key to decrypt incoming data and select Hexadecimal |
|
| or Text. This configuration field is only available if either TCP AES or UDP AES |
|
| protocol is selected. |
|
|
|
| Validate Certificate | Check to enable or disable validation certificate, if SSL protocol is selected. This |
|
| configuration field is only available if the SSL protocol is selected. |
|
| Enabling Validate Certificate requries the server to verify the remote SSL |
|
| server certificate when making a connection. |
|
| Disabling Validate Certificate causes the server to skip verification of the |
|
| remote SSL certificate. |
|
|
|
| Credentials | Specify the name of the set of RSA and/or DSA certificates and keys to be used |
|
| for the SSL connection. This configuration field is only available if the SSL |
|
| protocol is selected. |
|
|
|
|
| Table |
|
|
|
| Send Email Settings | Description |
| Add an Action | Select Send Email for the alarm or report. Repeat entry for the fields below of |
| each email. | |
|
|
|
| Alarm Email | Select an alarm profile number which will send an email when the alarm is turned |
|
| on. Multiple connection and reporting options will appear. |
|
|
|
| Normal Email | Select an alarm profile number which will send an email when the alarm is turned |
|
| off. Multiple normal email configuration options will appear. |
|
|
|
| Reporting | Check the types of reporting to include: |
|
| Serial Number |
|
| System Long Name |
|
| Terminal Block |
|
| Barrel Connector |
|
| Analog Input 1 |
|
| Analog Input 2 |
|
| Analog Output 1 (for xSenso 21A2 only) |
|
| Analog Output 2 (for xSenso 21A2 only) |
|
| Relay Output 1 (for xSenso 21R2 only) |
|
| Relay Output 2 (for xSenso 21R2 only) |
|
| Note: Your reporting selections made here will apply for both the alarm and |
|
| normal emails established. |
|
|
|
| Alarm Message | Specify the message that would appear in the alarm email message to be sent. |
|
|
|
| Alarm Reminder | Specify how long to wait in minutes after the alarm stays on before another alarm |
| Interval | email is sent. Blank the display field to disable reminders. Email will only be sent |
|
| once by default. |
|
|
|
| Normal Message | Specify the message that would appear in the normal email message to be sent. |
|
|
|
xSenso User Guide | 68 |