Lantronix XSENSO 2100, XSENSO 21R2 Control Relay Settings, Http Post Settings Description

Models: XSENSO 2100 XSENSO 21A2 XSENSO 21R2

1 125
Download 125 pages 5.09 Kb
Page 70
Image 70

 

 

13: Action Settings

 

 

Table 13-6 HTTP Post Settings

 

 

 

 

HTTP Post Settings

Description

 

Add an Action

Select HTTP Post for the alarm or report. The Host field will appear. You can

 

(drop-down menu)

create up to 2 connections. Repeat entry for the fields below of each HTTP Post

 

 

Host.

 

 

 

 

Host

Enter the HTTP server IP address or hostname to be connected to. Multiple

 

 

HTTP Post configuration options will appear.

 

 

 

 

Reporting

Check the types of reporting to include:

 

 

Serial Number

 

 

System Long Name

 

 

Terminal Block

 

 

Barrel Connector

 

 

Analog Input 1

 

 

Analog Input 2

 

 

Analog Output 1 (for xSenso 21A2 only)

 

 

Analog Output 2 (for xSenso 21A2 only)

 

 

Relay Output 1 (for xSenso 21R2 only)

 

 

Relay Output 2 (for xSenso 21R2 only)

 

 

Note: Your reporting selections made here will apply for all the connections

 

 

you make.

 

 

 

 

Reminder Interval

Specify how long to wait in minutes before trying to reconnect to the remote

 

 

host. Blank the display field to disable reminders. If more than one Connect

 

 

host is specified, connections are attempted without delay; so the single

 

 

Reminder Interval applies to the delay between successive attempts to them

 

 

all. Data will only be sent once by default.

 

 

 

 

Port

Enter the port number which HTTP server is listening to.

 

 

 

 

URL

Enter the URL to be used to post to remote HTTP server.

 

 

 

 

Protocol

Select the appropriate protocol to connect to the HTTP server: HTTP or

 

 

HTTPS.

 

 

 

 

Username

Specify the Username for logging on to the HTTP server. Both Basic and Digest

 

 

Authentications are supported. If HTTP server does not require authentication,

 

 

leave blank.

 

 

 

 

Password

Specify the Password for logging on to the HTTP server. If HTTP server does

 

 

not require authentication, leave blank.

 

 

 

Table 13-7 Control Relay Settings

Normally Open Port is closed to Common and Normally Closed Port is open/disconnected from Common when relay is energized/turned on. Normally Open Port is open/disconnected from Common and Normally Closed Port is closed to Common when relay is de-energized/turned off.

Note: Control relay settings are only available in the xSenso 21R2 and is not available for status reports.

Control Relay Settings

Description

Add an Action

Select Control Relay for the alarm. The Alarm Energize field will appear.

(drop-down menu)

 

 

 

Alarm Energize

Select either Relay 1 or Relay 2 to turn on when this is alarm is turned on.

 

Selecting None will cause the alarm state to have no effect on either relay.

 

 

xSenso User Guide

70

Page 70
Image 70
Lantronix XSENSO 2100, XSENSO 21R2, XSENSO 21A2 Http Post Settings Description, Control Relay Settings Description

XSENSO 2100, XSENSO 21A2, XSENSO 21R2 specifications

Lantronix, a leader in secure communications and IoT solutions, offers a range of innovative products that cater to various industrial and commercial needs. Among their impressive lineup are the XSENSO 21R2, XSENSO 21A2, and XSENSO 2100 devices, each designed for remote monitoring and control applications that require reliability and versatility.

The XSENSO 21R2 is a powerful device focused on advanced sensor management. It features multiple analog and digital inputs, enabling users to monitor a wide variety of environmental parameters such as temperature, humidity, and pressure. This model excels in applications requiring real-time data collection and analysis. Its robust construction ensures high performance in challenging environments, making it ideal for industrial settings. The XSENSO 21R2 also incorporates cloud connectivity options, allowing for seamless data transfer and integration with existing IoT infrastructures.

Similarly, the XSENSO 21A2 is designed for users who prioritize ease of use along with functionality. This device is equipped with a user-friendly interface that simplifies configuration and monitoring. It supports various communication protocols, ensuring compatibility with different systems and applications. The XSENSO 21A2 boasts a compact design, suitable for space-constrained installations, and provides options for local and remote access to data, enhancing user flexibility.

The XSENSO 2100 stands out with its high-performance processing capabilities, making it suitable for complex monitoring tasks. Its enhanced computing power allows it to run sophisticated analytics directly on the device, thereby reducing latency and bandwidth consumption. The XSENSO 2100 is especially useful in scenarios that require extensive data processing at the edge, such as predictive maintenance and machine learning applications. It is equipped with advanced security features, ensuring that sensitive data remains protected during transmission and storage.

All three models embody Lantronix's commitment to innovation, incorporating the latest technologies such as wireless connectivity options, cloud integration, and support for various industry standards. Their scalability makes them suitable for projects of all sizes, from small businesses to large enterprises. These devices not only enhance operational efficiency but also empower businesses to make data-driven decisions, ultimately leading to improved performance and cost savings. With Lantronix’s XSENSO devices, organizations can take a significant step towards realizing their IoT aspirations.