13: Action Settings

 

 

 

 

Contol Analog Output

Description

 

Settings (continued)

 

 

Output

Select the output number from the drop-down menu. Additional Analog Output

 

 

configuration fields become available if a specific output number is selected.

 

 

Selecting "None" stops control of analog output and does not reset the output

 

 

value.

 

 

 

 

Alarm Value

Provide the value to be asserted on the selected Analog Output when the alarm

 

 

is turned on.

 

 

 

 

Normal Value

Provide the value to be asserted on the selected Analog Output when alarm is

 

 

turned off.

 

 

 

 

 

Table 13-3 Make Connection Settings

 

 

 

 

Make Connection

Description

 

Settings

 

 

Add an Action

Select Make Connection for the alarm or report. The Address field will appear.

 

(drop-down menu)

You can create up to 10 connections. Repeat entry for the fields below of each

 

 

connection. There are a maximum of 10 connections for each alarm type and a

 

 

total of 40 hosts under “make connection” across all alarm types.

 

 

 

 

Address

To establish a connection when the alarm is on, provide either a DNS or IP

 

 

address of the remote host. Multiple connection and reporting options will

 

 

appear.

 

 

 

 

Reporting

Check the types of reporting to include:

 

 

Serial Number

 

 

System Long Name

 

 

Terminal Block

 

 

Barrel Connector

 

 

Analog Input 1

 

 

Analog Input 2

 

 

Analog Output 1

 

 

Analog Output 2

 

 

Relay Output 1

 

 

Relay Output 2

 

 

Note: Analog outputs are only supported for xSenso 21A2 and relay outputs are

 

 

only supported for xSenso 21R2. Your reporting selections made here will apply

 

 

for all the connections you make.

 

 

 

 

Reminder Interval

Specify how long to wait in seconds before trying to reconnect to the remote

 

 

host. Blank the display field to disable reminders. If more than one Connect host

 

 

is specified, connections are attempted without delay; so the single Reminder

 

 

Interval applies to the delay between successive attempts to them all. Data will

 

 

only be sent once by default.

 

 

 

 

Port

Enter the port number.

 

 

 

 

Mode

Select the mode:

 

 

Sequential

 

 

Simultaneous

 

 

Note: This configuration field appears when more than one connection is

 

 

enabled.

 

 

 

 

Protocol

Select the appropriate protocol: TCP, UDP, SSH, Telnet, TCP AES, UDP AES,

 

 

and SSL.

 

 

 

xSenso User Guide

67

Page 67
Image 67
Lantronix XSENSO 2100, XSENSO 21R2 manual Action Settings, Make Connection Settings, Make Connection Description Settings

XSENSO 2100, XSENSO 21A2, XSENSO 21R2 specifications

Lantronix, a leader in secure communications and IoT solutions, offers a range of innovative products that cater to various industrial and commercial needs. Among their impressive lineup are the XSENSO 21R2, XSENSO 21A2, and XSENSO 2100 devices, each designed for remote monitoring and control applications that require reliability and versatility.

The XSENSO 21R2 is a powerful device focused on advanced sensor management. It features multiple analog and digital inputs, enabling users to monitor a wide variety of environmental parameters such as temperature, humidity, and pressure. This model excels in applications requiring real-time data collection and analysis. Its robust construction ensures high performance in challenging environments, making it ideal for industrial settings. The XSENSO 21R2 also incorporates cloud connectivity options, allowing for seamless data transfer and integration with existing IoT infrastructures.

Similarly, the XSENSO 21A2 is designed for users who prioritize ease of use along with functionality. This device is equipped with a user-friendly interface that simplifies configuration and monitoring. It supports various communication protocols, ensuring compatibility with different systems and applications. The XSENSO 21A2 boasts a compact design, suitable for space-constrained installations, and provides options for local and remote access to data, enhancing user flexibility.

The XSENSO 2100 stands out with its high-performance processing capabilities, making it suitable for complex monitoring tasks. Its enhanced computing power allows it to run sophisticated analytics directly on the device, thereby reducing latency and bandwidth consumption. The XSENSO 2100 is especially useful in scenarios that require extensive data processing at the edge, such as predictive maintenance and machine learning applications. It is equipped with advanced security features, ensuring that sensitive data remains protected during transmission and storage.

All three models embody Lantronix's commitment to innovation, incorporating the latest technologies such as wireless connectivity options, cloud integration, and support for various industry standards. Their scalability makes them suitable for projects of all sizes, from small businesses to large enterprises. These devices not only enhance operational efficiency but also empower businesses to make data-driven decisions, ultimately leading to improved performance and cost savings. With Lantronix’s XSENSO devices, organizations can take a significant step towards realizing their IoT aspirations.