Lantronix XSENSO 21A2, XSENSO 21R2, XSENSO 2100 manual Using DeviceInstaller

Models: XSENSO 2100 XSENSO 21A2 XSENSO 21R2

1 125
Download 125 pages 5.09 Kb
Page 41
Image 41

6: Using DeviceInstaller

Current Settings

Description

 

Configurable field. Enter a group to categorize the xSenso. Double-click the

Group

field, type in the value, and press Enter to complete. This group name is

local to this PC and is not visible on other PCs or laptops using

 

 

DeviceInstaller.

 

 

 

Configurable field. Enter comments for the xSenso. Double-click the field,

Comments

type in the value, and press Enter to complete. This description or comment

is local to this PC and is not visible on other PCs or laptops using

 

 

DeviceInstaller.

 

 

Device Family

Shows the xSensodevice family type as “xSenso”.

 

 

Short Name

Shows “xSenso 2100”, “xSenso 21A2” or “xSenso 21R2” by default.

 

 

Long Name

Shows Lantronix xSenso 2100”, “Lantronix xSenso 21A2” or “Lantronix

 

xSenso 21R2” by default.

 

 

Type

Shows the device type as “xSenso 2100 Series”””.

 

 

ID

Shows the xSenso ID embedded within the unit.

 

 

Hardware Address

Shows the xSenso hardware (MAC) address.

 

 

Firmware Version

Shows the firmware currently installed on the xSenso.

 

 

Extended Firmware Version

Provides additional information on the firmware version.

 

 

Online Status

Shows the xSenso status as Online, Offline, Unreachable (the xSenso is on

 

a different subnet), or Busy (the xSenso is currently performing a task).

 

 

IP Address

Shows the xSenso current IP address. To change the IP address, click the

 

Assign IP button on the DeviceInstaller menu bar.

 

 

IP Address was Obtained

Appears “Dynamically” if the xSenso automatically received an IP address

 

(e.g., from DHCP). Appears “Statically” if the IP address was configured

 

manually.

 

If the IP address was assigned dynamically, the following fields appear:

 

Obtain via DHCP with values of True or False.

 

Obtain via BOOTP with values of True or False.

 

 

Subnet Mask

Shows the subnet mask specifying the network segment on which the

 

xSenso resides.

 

 

Gateway

Shows the IP address of the router of this network.

 

There is no default.

 

 

Number of Analog Inputs

Shows the number of analog inputs on the xSenso device.

 

 

Number of Analog Outputs

Shows the number of analog outputs on the xSenso device.

 

Note: This field only displays for xSenso 21A2 models.

 

 

Number of Relay Outputs

Shows the number of relay outputs on the xSenso device.

 

Note: This field only displays for xSenso 21R2 models.

 

 

Supports Configurable Pins

Shows False, indicating configurable pins are not available on the xSenso.

 

 

Supports Email Triggers

Shows True, indicating email triggers are available on the xSenso .

 

 

Telnet Supported

Indicates whether Telnet is enabled on this xSenso.

 

 

Telnet Port

Shows the xSenso port for Telnet sessions.

 

 

Web Port

Shows the xSenso port for web sessions.

 

 

Firmware Upgradable

Shows True, indicating the xSenso firmware is upgradable as newer

versions become available.

 

 

 

xSenso User Guide

41

Page 41
Image 41
Lantronix XSENSO 21A2, XSENSO 21R2, XSENSO 2100 manual Using DeviceInstaller