Omron DR 170 14 manual Klinkmann Automation Omron Ethernet DAServer

Page 16

Klinkmann Automation Omron Ethernet DAServer

14

by-time poll area D500…D509 and time-by-time gets u nsolicited command assigning to items D500…D509 values of PLCs D10…D19 area. Even i f corresponding Controller is configured to be processed in slave mode – at communication start-up DAServer process several general data reading commands, accessing toggle effect.

If your application does not need toggling effect – configure SEND(090) instruction so, that source area matches to destination area. In example – source data must start at D500, if data are sent to D500 onwards.

(3)Reset the Input creation.

(4)Turn ON error information flag CIO 001300 if error happens. In this case CIO 001300 is not mandatory; any other flag may be used. Note: The CS1-series CPU Unit’s Communication Port Error Flags are allocated the following - in Word A219: Bit 0 – is associated with Port 0, Bit 1 – is associated with Port 1, … , Bit 7 – is associated with Port 7. Bit’s status OFF - means Normal completion, ON – means Abnormal completion.

(5)The end of example program.

The example program ladder diagram is following:

Omron Ethernet DAServer Ver 1.x User Manual Rev 1.3

17014m13

Image 16
Contents Omron Ethernet Direct DAServer User’s Guide Ver 1.x Rev DR 170Contents About This User Guide ContentsIndex Introduction OverviewApplication Communications Protocols Communication ProtocolsSuiteLink Accessing Items via the DAServer Fins Message CommunicationFastDDE NetDDEDDE/SuiteLink Features Demo ModeBefore starting the Omron Ethernet DAServer Ethernet Unit Configuration Example for CS1 PLC Klinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer Comments on example program ladder diagram Example program for sending unsolicited data from PLCKlinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer Getting Started Quickly with the DAServer To prepare the Omron Ethernet DAServerNewSOCKET000 by default Configuring the DAServerAdd Controller Object To prepare the Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer To create Socket objects from the Configuration branch DASOmronEth Hierarchy in the DAServer ManagerPort Number Host Name IP AddrTo add Controller to your Omron Ethernet hierarchy Klinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer Device Group Definitions Configuring Device Group DefinitionsTo create or add device groups To make edits on device groups To configure default update intervals To delete device groupsTo edit update intervals Archiving Configuration SetsTo archive configuration sets Scan-Based Message HandlingConfiguring Device Item Definitions To use different configuration sets from the current oneDevice Item Definitions Name Item ReferenceTo create or add device items To add item referencesTo rename a device item from the list To delete a device item from the listTo export device items Hot ConfigurationTo import device items Item Name General Format PnSPnb or Pnbb or Pn.b or Pn.bb Pn-PhSBCD Format Long Format Signed/BCDFloating Point Format IEEE/BCD Ascii Strings FormatWrite ReadImortant Note = a To M CS1/CJ1 PLCs= a Klinkmann Automation Omron Ethernet DAServer C200HX/C200HG/C200HE PLCs CV-series PLCs PVS Flag or Bit Status Step StatusCPM2x PLCs Klinkmann Automation Omron Ethernet DAServer CQM1 PLCs DAServer Standard System Items DAServer Global System Item System Item Type Description Values Name Access RightsDAServer Device-Specific System Items Klinkmann Automation Omron Ethernet DAServer DAServer Device-Group-Specific System Items RangeRange Generic OPC Syntax AREA10.VESSEL1.TIC1.PLC.D100Monitoring Connectivity Status with the PLC YourOPCAccessPath.$SYS$Status=DASOmronEthPLC!$SYS$Status Monitoring the Status of DAS Conversations Using DDEStatus and IOStatus in ExcelReading Values from the DAServer into Excel Writing Values to the DAServer from Excel Channel=INITIATEapplicationname,topicname=POKEchannel,itemname, DataReference =TERMINATEchannelDAServer Error Messages Error Messages and CodesError Message Explanation Probable Cause Solution Log Flag Item Names Creating write Invalid value poked Check Item’s DASProtFail Data, received Take into DASProtWarn Server-Specific Error Codes Error code Logger Message Log FlagFins Response Codes Main Code Sub Probable Cause Remedy Log Flag HexKlinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer DAServer Architecture DAServersDAS Engine Plug-insPLC Protocol Layer Component Environments Klinkmann Automation
Related manuals
Manual 70 pages 30.48 Kb

DR 170 14 specifications

The Omron DR 170 14 is a leading-edge digital infrared thermometer that has established a strong reputation for its accuracy and efficiency in measuring body temperature. This advanced device is particularly noted for its user-friendly design, making it suitable for both medical professionals and home use.

One of the key features of the Omron DR 170 14 is its non-contact measurement capability, allowing users to obtain temperature readings from a distance of about 1-3 centimeters. This feature is crucial in minimizing the risk of cross-contamination, especially in healthcare settings. The thermometer utilizes infrared technology to detect the infrared energy emitted by the body, ensuring quick and reliable readings in just seconds.

The Omron DR 170 14 also boasts a large, easy-to-read LCD display that provides clear visibility of temperature readings. This display is backlit, allowing for usage in low-light conditions, making it convenient during nighttime monitoring of children's temperatures.

Furthermore, the device includes a memory function that can store multiple temperature readings, assisting users in tracking fever patterns over time. This feature is invaluable for caregivers and healthcare providers as it allows for better assessment and decision-making regarding treatment plans.

In terms of accuracy, the Omron DR 170 14 is equipped with advanced measurement algorithms that enhance precision in readings, positioning it as a reliable option for temperature measurement. The thermometer can measure not only body temperature but also surface temperatures of objects and liquids, providing versatility beyond just clinical settings.

Another notable characteristic is its compact and lightweight design, which makes it highly portable and easy to carry around, whether in a medical bag or a home setting. The thermometer is also powered by batteries, ensuring that it remains operational even in case of power outages.

Overall, the Omron DR 170 14 stands out for its combination of modern technology, ease of use, and reliable performance. With its non-contact functionality, rapid readings, and memory features, it serves as an essential tool for anyone needing accurate temperature assessments, whether in a clinical or home environment. The thermometer exemplifies Omron's commitment to creating healthcare solutions that are not only innovative but also accessible to a wide range of users.