Omron DR 170 14 manual DAServer Global System Item, DAServer Device-Specific System Items

Page 47

Klinkmann Automation Omron Ethernet DAServer

45

DAServer Global System Item

The following system item refers to specific information regarding a global condition of the DAServer.

System Item

Type/

Description

Values

Name

Access

 

 

 

Rights

 

 

$SYS$Licensed

Boolean/

Binary status indication of the

RANGE: 0, 1

 

Read

existence of a valid license for the

1: Valid license

 

 

DAServer.

 

 

If FALSE, this item causes the

exists.

 

 

DAServer to stop updating existing

0: No valid

 

 

tags, to refuse activation of new tags,

 

 

and to reject write requests in addition

license exists.

 

 

to setting quality for all items to BAD.

 

 

 

If TRUE, the DAServer functions as

 

 

 

configured.

 

 

 

All instances have the same value.

 

Note: With Omron Ethernet DAServer Global System Item $SYS$Licensed is not relevant.

DAServer Device-Specific System Items

The following system items refer to specific information regarding the device(s) the DAServer is connected to.

System Item

Type/

Description

Values

Name

Access

 

 

 

Rights

 

 

$SYS$Status

Boolean/

Binary status indication of the

RANGE: 0, 1

 

Read

connection state to the device

1: DAServer

 

 

(hierarchy level) the item is

 

 

attached to.

connection to the

 

 

The device group (OPC access

device is intact.

 

 

path/topic) does not affect the

0: Error

 

 

value. The status can be good

communicating

 

 

even if individual items have

with the device.

 

 

errors.

 

 

 

For DDE/SuiteLink clients,

 

 

 

$SYS$Status always comes

 

 

 

from the leaf level of a DAServer

 

 

 

hierarchy branch, which is the

 

 

 

destination PLC node.

 

 

 

For OPC clients, $SYS$Status

 

 

 

can be accessed at all hierarchy

 

 

 

levels. $SYS$Status at the root

 

 

 

level of the whole hierarchy tree

 

 

 

is always good, as it represents

 

 

 

the quality status of the local

 

 

 

computer itself. Hence, for

 

Omron Ethernet DAServer Ver 1.x User Manual Rev 1.3

17014m13

Image 47
Contents Ver 1.x Rev DR 170 Omron Ethernet Direct DAServer User’s GuideContents Index ContentsAbout This User Guide Overview IntroductionSuiteLink Communication ProtocolsApplication Communications Protocols NetDDE Accessing Items via the DAServerFins Message Communication FastDDEDDE/SuiteLink Demo Mode FeaturesBefore starting the Omron Ethernet DAServer Ethernet Unit Configuration Example for CS1 PLC Klinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer Example program for sending unsolicited data from PLC Comments on example program ladder diagramKlinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer To prepare the Omron Ethernet DAServer Getting Started Quickly with the DAServerAdd Controller Object Configuring the DAServerNewSOCKET000 by default To prepare the Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer DASOmronEth Hierarchy in the DAServer Manager To create Socket objects from the Configuration branchTo add Controller to your Omron Ethernet hierarchy Host Name IP AddrPort Number Klinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer To create or add device groups Configuring Device Group DefinitionsDevice Group Definitions To make edits on device groups To delete device groups To configure default update intervalsScan-Based Message Handling To edit update intervalsArchiving Configuration Sets To archive configuration setsName Item Reference Configuring Device Item DefinitionsTo use different configuration sets from the current one Device Item DefinitionsTo delete a device item from the list To create or add device itemsTo add item references To rename a device item from the listTo import device items Hot ConfigurationTo export device items Pn-PhS Item Name General FormatPnS Pnb or Pnbb or Pn.b or Pn.bbAscii Strings Format BCD FormatLong Format Signed/BCD Floating Point Format IEEE/BCDImortant Note ReadWrite = a CS1/CJ1 PLCs= a To M Klinkmann Automation Omron Ethernet DAServer C200HX/C200HG/C200HE PLCs CV-series PLCs PVS Step Status Flag or Bit StatusCPM2x PLCs Klinkmann Automation Omron Ethernet DAServer CQM1 PLCs DAServer Standard System Items DAServer Device-Specific System Items System Item Type Description Values Name Access RightsDAServer Global System Item Klinkmann Automation Omron Ethernet DAServer Range DAServer Device-Group-Specific System ItemsRange AREA10.VESSEL1.TIC1.PLC.D100 Generic OPC Syntax=DASOmronEthPLC!$SYS$Status YourOPCAccessPath.$SYS$StatusMonitoring Connectivity Status with the PLC Reading Values from the DAServer into Excel Using DDEStatus and IOStatus in ExcelMonitoring the Status of DAS Conversations =TERMINATEchannel Writing Values to the DAServer from ExcelChannel=INITIATEapplicationname,topicname =POKEchannel,itemname, DataReferenceError Message Explanation Probable Cause Solution Log Flag Error Messages and CodesDAServer Error Messages Item Names Creating write Invalid value poked Check Item’s DASProtFail Data, received Take into DASProtWarn Main Code Sub Probable Cause Remedy Log Flag Hex Server-Specific Error CodesError code Logger Message Log Flag Fins Response CodesKlinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer DAServers DAServer ArchitecturePLC Protocol Layer Plug-insDAS Engine Component Environments Klinkmann Automation
Related manuals
Manual 70 pages 30.48 Kb

DR 170 14 specifications

The Omron DR 170 14 is a leading-edge digital infrared thermometer that has established a strong reputation for its accuracy and efficiency in measuring body temperature. This advanced device is particularly noted for its user-friendly design, making it suitable for both medical professionals and home use.

One of the key features of the Omron DR 170 14 is its non-contact measurement capability, allowing users to obtain temperature readings from a distance of about 1-3 centimeters. This feature is crucial in minimizing the risk of cross-contamination, especially in healthcare settings. The thermometer utilizes infrared technology to detect the infrared energy emitted by the body, ensuring quick and reliable readings in just seconds.

The Omron DR 170 14 also boasts a large, easy-to-read LCD display that provides clear visibility of temperature readings. This display is backlit, allowing for usage in low-light conditions, making it convenient during nighttime monitoring of children's temperatures.

Furthermore, the device includes a memory function that can store multiple temperature readings, assisting users in tracking fever patterns over time. This feature is invaluable for caregivers and healthcare providers as it allows for better assessment and decision-making regarding treatment plans.

In terms of accuracy, the Omron DR 170 14 is equipped with advanced measurement algorithms that enhance precision in readings, positioning it as a reliable option for temperature measurement. The thermometer can measure not only body temperature but also surface temperatures of objects and liquids, providing versatility beyond just clinical settings.

Another notable characteristic is its compact and lightweight design, which makes it highly portable and easy to carry around, whether in a medical bag or a home setting. The thermometer is also powered by batteries, ensuring that it remains operational even in case of power outages.

Overall, the Omron DR 170 14 stands out for its combination of modern technology, ease of use, and reliable performance. With its non-contact functionality, rapid readings, and memory features, it serves as an essential tool for anyone needing accurate temperature assessments, whether in a clinical or home environment. The thermometer exemplifies Omron's commitment to creating healthcare solutions that are not only innovative but also accessible to a wide range of users.