Omron DR 170 14 manual DAServer Standard System Items

Page 46

Klinkmann Automation Omron Ethernet DAServer

44

102

-

IR Output area (Word contents), word address 102

LR62.10

-

LR area (Bit status), word address 62, bit number 10

DM21

-

DM area (Word contents), word address 21

DAServer Standard System Items

System Items provide you with easy access to the DAServer status and diagnostics information. They are treated just like ordinary items with respect to the client. However, in most cases these items are not directly acquired via the communications layer. System item values are usually generated through internal calculations, measurements, and the tracking of the DAS Engine.

No DAServer-specific system items are provided in this Omron Ethernet DAServer.

System items, like ordinary items, are defined by the following properties:

Group (client group/OPC group): The arbitrary collection of items, not correlated.

Hierarchical location (link name/OPC path. The hierarchical node section of the fully qualified OPC item ID.): The device the item is attached to.

Device group (OPC access path/topic, or a Scan Group on a hierarchical branch.): A collection of items on the same physical location with the same protocol update rate. Example:

To check the status of an external device, the reference might be: DASOmronEth.Socket1.$SYS$Status

Note: This syntax does not refer to the access path/device group. As long as the data requested is from the same external device, the value will always be the same.

Note: For DDE/SuiteLink clients, $SYS$Status always comes from the leaf level of a DAServer hierarchy branch, which is the destination PLC node. For OPC clients, $SYS$Status can be accessed at all hierarchy levels. $SYS$Status at the root level of the whole hierarchy tree is always good, as it represents the quality status of the local computer itself. Hence, for practical application, OPC clients should reference $SYS$Status at any hierarchy levels other than the root.

In the ArchestrA context, the device group plays the most important role of identifying the scope of any item (the device group defines the hierarchical location implicitly when using globally unique device-group names, which is required for DDE/SuiteLink compatibility).

All system items follow the same naming convention:

All system items start with $SYS$.

The DAS Engine scans and parses the name for system items.

Parsing of the name is case-insensitive.

All system items can be accessed through subscriptions to a device group. However, while some system items return data for that device group, others are server-wide.

Omron Ethernet DAServer Ver 1.x User Manual Rev 1.3

17014m13

Image 46
Contents Omron Ethernet Direct DAServer User’s Guide Ver 1.x Rev DR 170Contents About This User Guide ContentsIndex Introduction OverviewApplication Communications Protocols Communication ProtocolsSuiteLink FastDDE Accessing Items via the DAServerFins Message Communication NetDDEDDE/SuiteLink Features Demo ModeBefore starting the Omron Ethernet DAServer Ethernet Unit Configuration Example for CS1 PLC Klinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer Comments on example program ladder diagram Example program for sending unsolicited data from PLCKlinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer Getting Started Quickly with the DAServer To prepare the Omron Ethernet DAServerNewSOCKET000 by default Configuring the DAServerAdd Controller Object To prepare the Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer To create Socket objects from the Configuration branch DASOmronEth Hierarchy in the DAServer ManagerPort Number Host Name IP AddrTo add Controller to your Omron Ethernet hierarchy Klinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer Device Group Definitions Configuring Device Group DefinitionsTo create or add device groups To make edits on device groups To configure default update intervals To delete device groupsTo archive configuration sets To edit update intervalsArchiving Configuration Sets Scan-Based Message HandlingDevice Item Definitions Configuring Device Item DefinitionsTo use different configuration sets from the current one Name Item ReferenceTo rename a device item from the list To create or add device itemsTo add item references To delete a device item from the listTo export device items Hot ConfigurationTo import device items Pnb or Pnbb or Pn.b or Pn.bb Item Name General FormatPnS Pn-PhSFloating Point Format IEEE/BCD BCD FormatLong Format Signed/BCD Ascii Strings FormatWrite ReadImortant Note = a To M CS1/CJ1 PLCs= a Klinkmann Automation Omron Ethernet DAServer C200HX/C200HG/C200HE PLCs CV-series PLCs PVS Flag or Bit Status Step StatusCPM2x PLCs Klinkmann Automation Omron Ethernet DAServer CQM1 PLCs DAServer Standard System Items DAServer Global System Item System Item Type Description Values Name Access RightsDAServer Device-Specific System Items Klinkmann Automation Omron Ethernet DAServer DAServer Device-Group-Specific System Items RangeRange Generic OPC Syntax AREA10.VESSEL1.TIC1.PLC.D100Monitoring Connectivity Status with the PLC YourOPCAccessPath.$SYS$Status=DASOmronEthPLC!$SYS$Status Monitoring the Status of DAS Conversations Using DDEStatus and IOStatus in ExcelReading Values from the DAServer into Excel =POKEchannel,itemname, DataReference Writing Values to the DAServer from ExcelChannel=INITIATEapplicationname,topicname =TERMINATEchannelDAServer Error Messages Error Messages and CodesError Message Explanation Probable Cause Solution Log Flag Item Names Creating write Invalid value poked Check Item’s DASProtFail Data, received Take into DASProtWarn Fins Response Codes Server-Specific Error CodesError code Logger Message Log Flag Main Code Sub Probable Cause Remedy Log Flag HexKlinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer DAServer Architecture DAServersDAS Engine Plug-insPLC Protocol Layer Component Environments Klinkmann Automation
Related manuals
Manual 70 pages 30.48 Kb

DR 170 14 specifications

The Omron DR 170 14 is a leading-edge digital infrared thermometer that has established a strong reputation for its accuracy and efficiency in measuring body temperature. This advanced device is particularly noted for its user-friendly design, making it suitable for both medical professionals and home use.

One of the key features of the Omron DR 170 14 is its non-contact measurement capability, allowing users to obtain temperature readings from a distance of about 1-3 centimeters. This feature is crucial in minimizing the risk of cross-contamination, especially in healthcare settings. The thermometer utilizes infrared technology to detect the infrared energy emitted by the body, ensuring quick and reliable readings in just seconds.

The Omron DR 170 14 also boasts a large, easy-to-read LCD display that provides clear visibility of temperature readings. This display is backlit, allowing for usage in low-light conditions, making it convenient during nighttime monitoring of children's temperatures.

Furthermore, the device includes a memory function that can store multiple temperature readings, assisting users in tracking fever patterns over time. This feature is invaluable for caregivers and healthcare providers as it allows for better assessment and decision-making regarding treatment plans.

In terms of accuracy, the Omron DR 170 14 is equipped with advanced measurement algorithms that enhance precision in readings, positioning it as a reliable option for temperature measurement. The thermometer can measure not only body temperature but also surface temperatures of objects and liquids, providing versatility beyond just clinical settings.

Another notable characteristic is its compact and lightweight design, which makes it highly portable and easy to carry around, whether in a medical bag or a home setting. The thermometer is also powered by batteries, ensuring that it remains operational even in case of power outages.

Overall, the Omron DR 170 14 stands out for its combination of modern technology, ease of use, and reliable performance. With its non-contact functionality, rapid readings, and memory features, it serves as an essential tool for anyone needing accurate temperature assessments, whether in a clinical or home environment. The thermometer exemplifies Omron's commitment to creating healthcare solutions that are not only innovative but also accessible to a wide range of users.