Omron DR 170 14 manual Creating write Invalid value poked Check Item’s DASProtFail

Page 57

 

Klinkmann Automation Omron Ethernet DAServer

 

 

55

 

 

 

 

 

 

 

 

 

 

Item <ItemName>

of response

 

read messages for

message

 

 

 

(<Pointer to

message)

 

such Item types as

length for

 

 

 

Item_Class_Obj.>)

exceeds max

 

discrete, integer,

Controller

 

 

 

was not created: max

read message

 

long or floating

object, or

 

 

 

allowed message's

length,

 

point. When poll

change item

 

 

 

length <Max_Length>

configured for

 

multiple

name

 

 

 

is not sufficient.

Controller

 

consecutive 16-bit

(decrease

 

 

 

 

object.

 

words as ASCII

number of

 

 

 

 

 

 

string Item – you

words in

 

 

 

 

 

 

could face this

ASCII string

 

 

 

 

 

 

error condition if

Item).

 

 

 

 

 

 

configuring too

 

 

 

 

 

 

 

small max read

 

 

 

 

 

 

 

message length.

 

 

 

 

<Socket_

Creating write

 

Invalid value poked

Check Item’s

DASProtFail

 

ControllerName>:

command

 

or DAServer

value to

 

 

 

CreatePokeMessage,

failed.

 

processing error.

poke. Repeat

 

 

 

cannot get Item's

 

 

 

the poke

 

 

 

<ItemName>

 

 

 

processing.

 

 

 

(<Pointer to

 

 

 

 

 

 

 

Item_Class_Obj.>)

 

 

 

 

 

 

 

value, error =

 

 

 

 

 

 

 

<Error_Code>

 

 

 

 

 

 

 

<Socket_

Length of write

 

Usually there

Configure

DASProtFail

 

ControllerName>:

message for

 

shouldn’t be any

satisfactory

 

 

 

Write message for

Item (or length

 

problems creating

max write

 

 

 

Item <ItemName>

of response

 

write messages for

message

 

 

 

(<Pointer to

message)

 

such Item types as

length for

 

 

 

Item_Class_Obj.>)

exceeds max.

 

discrete, integer,

Controller

 

 

 

was not created: max

write message

 

long or floating

object, or

 

 

 

allowed message's

length,

 

point. When poke

change item

 

 

 

length <Max_Length>

configured for

 

multiple

name

 

 

 

is not sufficient.

Controller

 

consecutive 16-bit

(decrease

 

 

 

 

object.

 

words as ASCII

number of

 

 

 

 

 

 

string Item – you

words in

 

 

 

 

 

 

could face this

ASCII string

 

 

 

 

 

 

error condition if

Item).

 

 

 

 

 

 

configuring too

 

 

 

 

 

 

 

small max write

 

 

 

 

 

 

 

message length.

 

 

 

 

<Socket_

Writing of new

 

Timing problems or

Repeat poke

DASProtFail

 

ControllerName>:

value into bit-

 

DAServer code

processing.

 

 

 

Write message for

of-word is

 

processing

 

 

 

 

Item <ItemName>

processed in

 

problems.

 

 

 

 

(<Pointer to

two steps: a)

 

 

 

 

 

 

Item_Class_Obj.>)

reading of

 

 

 

 

 

 

was not created.

corresponding

 

 

 

 

 

 

Preparing of read

word value, b)

 

 

 

 

 

 

command for bit

overwriting bit

 

 

 

 

 

 

writing failed.

value in word

 

 

 

 

 

Omron Ethernet DAServer Ver 1.x User Manual Rev 1.3

17014m13

Image 57
Contents Ver 1.x Rev DR 170 Omron Ethernet Direct DAServer User’s GuideContents Contents About This User GuideIndex Overview IntroductionCommunication Protocols Application Communications ProtocolsSuiteLink Fins Message Communication Accessing Items via the DAServerFastDDE NetDDEDDE/SuiteLink Demo Mode FeaturesBefore starting the Omron Ethernet DAServer Ethernet Unit Configuration Example for CS1 PLC Klinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer Example program for sending unsolicited data from PLC Comments on example program ladder diagramKlinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer To prepare the Omron Ethernet DAServer Getting Started Quickly with the DAServerConfiguring the DAServer NewSOCKET000 by defaultAdd Controller Object To prepare the Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer DASOmronEth Hierarchy in the DAServer Manager To create Socket objects from the Configuration branchHost Name IP Addr Port NumberTo add Controller to your Omron Ethernet hierarchy Klinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer Configuring Device Group Definitions Device Group DefinitionsTo create or add device groups To make edits on device groups To delete device groups To configure default update intervalsArchiving Configuration Sets To edit update intervalsTo archive configuration sets Scan-Based Message HandlingTo use different configuration sets from the current one Configuring Device Item DefinitionsDevice Item Definitions Name Item ReferenceTo add item references To create or add device itemsTo rename a device item from the list To delete a device item from the listHot Configuration To export device itemsTo import device items PnS Item Name General FormatPnb or Pnbb or Pn.b or Pn.bb Pn-PhSLong Format Signed/BCD BCD FormatFloating Point Format IEEE/BCD Ascii Strings FormatRead WriteImortant Note CS1/CJ1 PLCs = a To M= a Klinkmann Automation Omron Ethernet DAServer C200HX/C200HG/C200HE PLCs CV-series PLCs PVS Step Status Flag or Bit StatusCPM2x PLCs Klinkmann Automation Omron Ethernet DAServer CQM1 PLCs DAServer Standard System Items System Item Type Description Values Name Access Rights DAServer Global System ItemDAServer Device-Specific System Items Klinkmann Automation Omron Ethernet DAServer Range DAServer Device-Group-Specific System ItemsRange AREA10.VESSEL1.TIC1.PLC.D100 Generic OPC SyntaxYourOPCAccessPath.$SYS$Status Monitoring Connectivity Status with the PLC=DASOmronEthPLC!$SYS$Status Using DDEStatus and IOStatus in Excel Monitoring the Status of DAS ConversationsReading Values from the DAServer into Excel Channel=INITIATEapplicationname,topicname Writing Values to the DAServer from Excel=POKEchannel,itemname, DataReference =TERMINATEchannelError Messages and Codes DAServer Error MessagesError Message Explanation Probable Cause Solution Log Flag Item Names Creating write Invalid value poked Check Item’s DASProtFail Data, received Take into DASProtWarn Error code Logger Message Log Flag Server-Specific Error CodesFins Response Codes Main Code Sub Probable Cause Remedy Log Flag HexKlinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer DAServers DAServer ArchitecturePlug-ins DAS EnginePLC Protocol Layer Component Environments Klinkmann Automation
Related manuals
Manual 70 pages 30.48 Kb

DR 170 14 specifications

The Omron DR 170 14 is a leading-edge digital infrared thermometer that has established a strong reputation for its accuracy and efficiency in measuring body temperature. This advanced device is particularly noted for its user-friendly design, making it suitable for both medical professionals and home use.

One of the key features of the Omron DR 170 14 is its non-contact measurement capability, allowing users to obtain temperature readings from a distance of about 1-3 centimeters. This feature is crucial in minimizing the risk of cross-contamination, especially in healthcare settings. The thermometer utilizes infrared technology to detect the infrared energy emitted by the body, ensuring quick and reliable readings in just seconds.

The Omron DR 170 14 also boasts a large, easy-to-read LCD display that provides clear visibility of temperature readings. This display is backlit, allowing for usage in low-light conditions, making it convenient during nighttime monitoring of children's temperatures.

Furthermore, the device includes a memory function that can store multiple temperature readings, assisting users in tracking fever patterns over time. This feature is invaluable for caregivers and healthcare providers as it allows for better assessment and decision-making regarding treatment plans.

In terms of accuracy, the Omron DR 170 14 is equipped with advanced measurement algorithms that enhance precision in readings, positioning it as a reliable option for temperature measurement. The thermometer can measure not only body temperature but also surface temperatures of objects and liquids, providing versatility beyond just clinical settings.

Another notable characteristic is its compact and lightweight design, which makes it highly portable and easy to carry around, whether in a medical bag or a home setting. The thermometer is also powered by batteries, ensuring that it remains operational even in case of power outages.

Overall, the Omron DR 170 14 stands out for its combination of modern technology, ease of use, and reliable performance. With its non-contact functionality, rapid readings, and memory features, it serves as an essential tool for anyone needing accurate temperature assessments, whether in a clinical or home environment. The thermometer exemplifies Omron's commitment to creating healthcare solutions that are not only innovative but also accessible to a wide range of users.