Omron DR 170 14 manual Before starting the Omron Ethernet DAServer

Page 9

Klinkmann Automation Omron Ethernet DAServer

7

CHAPTER 2

Before starting the OMRON Ethernet DAServer

This chapter contains instructions how to configure OMRON PLCs to be accessible by Omron Ethernet DAServer in OMRON Ethernet FA network.

Configuration example deals with local network. If data are to be accessed from remote networks then Relay Network Tables must be additionally configured in the PLC.

Contents

Preparing the Hardware to be Used with Omron Ethernet DAServer

Ethernet Unit Configuration Example for CS1 PLC

Example program for sending “unsolicited” data from PLC

Preparing the Hardware to be used with OMRON Ethernet DAServer

The Omron Ethernet DAServer requires an Ethernet card and TCP/IP protocol supporting Windows Sockets interface to be installed on the computer to communicate with the OMRON PLCs over the Ethernet network.

Each connected OMRON Controller (with Ethernet Unit installed) must be configured to allow it to function as a node on the Ethernet network. This setup can be done by switches on the module and/or appropriate programming software.

The OMRON C200HX/C200HG/C200HE PLCs (except CPU11), CV-series PLCs, CS1 PLCs as well as CJ1 PLCs can be used as nodes on Ethernet network. The C200HX/C200HG/C200HE PLCs must be supplied with communication module: C200HW-PCS01-EV1 Ethernet Set or C200HW-PCU01 PC Card Unit supplied with the Ethernet PC Card (e.g. Kingston T.C. EtheRxEthernet PC Card models: KNE-PCM/M – for coaxial and twisted pair connection, KNE-PCM/T – for twisted pair connection).

The CS1-series PLCs must be supplied with CS1W-ETN01 Ethernet Unit. The CJ1-series PLCs must be supplied with CJ1W-ETN11 Ethernet Unit.

The CV-series PLCs must be supplied with CV500-ETN01 communication module.

The Ethernet PC Card installed in the C200HW-PCU01 PC Card Unit in the C200HX/C200HG/C200HE PLC is configured by software supplied with communication hardware.

Node number and Unit number of CV500-ETN01 (in CV-series PLC) is set by rotary switches on the module. Software (CVSS software, SYSWIN or CX-Programmer) is used to configure IP Address, Routing tables and IP Address tables.

Node number and Unit number of CS1W-ETN01 Ethernet Unit (in CS1-series PLC) is set by rotary switches on the front side of module. Local IP Address is set by switches SW1, SW2, ..., SW8 on the back side of module. Software (CX-Programmer) is used to configure Routing tables and IP Address tables.

Node number and Unit number of CJ1W-ETN11 Ethernet Unit (in CJ1-series PLC) is set by rotary switches on the front side of module. Software (CX-Programmer) is used to configure Routing tables, local IP Address and IP Address tables.

Omron Ethernet DAServer Ver 1.x User Manual Rev 1.3

17014m13

Image 9
Contents Ver 1.x Rev DR 170 Omron Ethernet Direct DAServer User’s GuideContents Contents About This User GuideIndex Overview IntroductionCommunication Protocols Application Communications ProtocolsSuiteLink Fins Message Communication Accessing Items via the DAServerFastDDE NetDDEDDE/SuiteLink Demo Mode FeaturesBefore starting the Omron Ethernet DAServer Ethernet Unit Configuration Example for CS1 PLC Klinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer Example program for sending unsolicited data from PLC Comments on example program ladder diagramKlinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer To prepare the Omron Ethernet DAServer Getting Started Quickly with the DAServerConfiguring the DAServer NewSOCKET000 by defaultAdd Controller Object To prepare the Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer DASOmronEth Hierarchy in the DAServer Manager To create Socket objects from the Configuration branchHost Name IP Addr Port NumberTo add Controller to your Omron Ethernet hierarchy Klinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer Configuring Device Group Definitions Device Group DefinitionsTo create or add device groups To make edits on device groups To delete device groups To configure default update intervalsArchiving Configuration Sets To edit update intervalsTo archive configuration sets Scan-Based Message HandlingTo use different configuration sets from the current one Configuring Device Item DefinitionsDevice Item Definitions Name Item ReferenceTo add item references To create or add device itemsTo rename a device item from the list To delete a device item from the listHot Configuration To export device itemsTo import device items PnS Item Name General FormatPnb or Pnbb or Pn.b or Pn.bb Pn-PhSLong Format Signed/BCD BCD FormatFloating Point Format IEEE/BCD Ascii Strings FormatRead WriteImortant Note CS1/CJ1 PLCs = a To M= a Klinkmann Automation Omron Ethernet DAServer C200HX/C200HG/C200HE PLCs CV-series PLCs PVS Step Status Flag or Bit StatusCPM2x PLCs Klinkmann Automation Omron Ethernet DAServer CQM1 PLCs DAServer Standard System Items System Item Type Description Values Name Access Rights DAServer Global System ItemDAServer Device-Specific System Items Klinkmann Automation Omron Ethernet DAServer Range DAServer Device-Group-Specific System ItemsRange AREA10.VESSEL1.TIC1.PLC.D100 Generic OPC SyntaxYourOPCAccessPath.$SYS$Status Monitoring Connectivity Status with the PLC=DASOmronEthPLC!$SYS$Status Using DDEStatus and IOStatus in Excel Monitoring the Status of DAS ConversationsReading Values from the DAServer into Excel Channel=INITIATEapplicationname,topicname Writing Values to the DAServer from Excel=POKEchannel,itemname, DataReference =TERMINATEchannelError Messages and Codes DAServer Error MessagesError Message Explanation Probable Cause Solution Log Flag Item Names Creating write Invalid value poked Check Item’s DASProtFail Data, received Take into DASProtWarn Error code Logger Message Log Flag Server-Specific Error CodesFins Response Codes Main Code Sub Probable Cause Remedy Log Flag HexKlinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer Klinkmann Automation Omron Ethernet DAServer DAServers DAServer ArchitecturePlug-ins DAS EnginePLC Protocol Layer Component Environments Klinkmann Automation
Related manuals
Manual 70 pages 30.48 Kb

DR 170 14 specifications

The Omron DR 170 14 is a leading-edge digital infrared thermometer that has established a strong reputation for its accuracy and efficiency in measuring body temperature. This advanced device is particularly noted for its user-friendly design, making it suitable for both medical professionals and home use.

One of the key features of the Omron DR 170 14 is its non-contact measurement capability, allowing users to obtain temperature readings from a distance of about 1-3 centimeters. This feature is crucial in minimizing the risk of cross-contamination, especially in healthcare settings. The thermometer utilizes infrared technology to detect the infrared energy emitted by the body, ensuring quick and reliable readings in just seconds.

The Omron DR 170 14 also boasts a large, easy-to-read LCD display that provides clear visibility of temperature readings. This display is backlit, allowing for usage in low-light conditions, making it convenient during nighttime monitoring of children's temperatures.

Furthermore, the device includes a memory function that can store multiple temperature readings, assisting users in tracking fever patterns over time. This feature is invaluable for caregivers and healthcare providers as it allows for better assessment and decision-making regarding treatment plans.

In terms of accuracy, the Omron DR 170 14 is equipped with advanced measurement algorithms that enhance precision in readings, positioning it as a reliable option for temperature measurement. The thermometer can measure not only body temperature but also surface temperatures of objects and liquids, providing versatility beyond just clinical settings.

Another notable characteristic is its compact and lightweight design, which makes it highly portable and easy to carry around, whether in a medical bag or a home setting. The thermometer is also powered by batteries, ensuring that it remains operational even in case of power outages.

Overall, the Omron DR 170 14 stands out for its combination of modern technology, ease of use, and reliable performance. With its non-contact functionality, rapid readings, and memory features, it serves as an essential tool for anyone needing accurate temperature assessments, whether in a clinical or home environment. The thermometer exemplifies Omron's commitment to creating healthcare solutions that are not only innovative but also accessible to a wide range of users.