Omega Speaker Systems iLD Series manual Telnet Setup iServer Help

Page 31

4.9 Telnet Setup (continued)

In the Configuration mode you can make any changes just like you would do using the Web Browser. After connected to the iServer, the user can use the following commands to read, modify, and get help from the iServer console.

?Following with a return character, the console will show all the commands and options (Figure 4.17). p Following with a return character, the console will show the iServer configurations (Figure 4.16).

sIs the configuration command, used to set a new setting (see the example in Figure 4.17) r This command is used to read the status of the digital I/O signals (0 is low and 1 is high)

Example:

r DCD

response will be

DCD (DSR)=0

 

r DTR

response will be

DTR=0

wThis command is used to change the status of the digital I/O signals (applies only to the outgoing signals, DTR and RTS)

Example : w RTS=1 means raise the RTS

w DTR=0 means lower the DTR

RESET following with a return character, it will recycle the Power on the iServer.

FACTORY following with a return character, it will set the iServer to it’s factory default settings.

Admin. Password:00000000

Admin. Login Successful

iServer Configuration Command:

?

 

 

 

cc description

pppppp

 

 

BD BaudRate

0-300,1-600,2-1200,3-2400,4-4800,5-9600,6-19200,

 

7-38400, 8-57600, 9-115200

PT Parity

0-none,1-Odd,2-even

ST StopBits

0-1bits,1-2bits

 

DT DataBits

0-7bits,1-8bits

 

FC FlowControl

0-none,1-XON/XOFF,2-Hardware

MD Mode

0-RS232, 1-RS485

MB Modbus/TCP

0-disable, 1-enable

TO TimeOut

xxxx ms Rang range 100-9999

TU TCP/UDP

0-TCP, 1-UDP

 

 

TT TerminalType

0-Host, 1-Slave

 

TN TerminalNumber

0-5

 

 

PP TerminalPort

XXXXX 500-65535

but 1000 and 2002

HN HostName

XXXXXXXX

maxim 18 characters

IP Static IP

XXX.XXX.XXX.XXX

 

LP Login Password

XXXXXX maxim 16

characters

SP Admin Password

XXXXXX maxim 16

characters

TP Device Type

0-iServer,1-iDRN,2-iDRX,3-iSeries,4-iNFB,5-iLD

RE Remote Enable

0-Disable, 1-Enable

RI Remote IP

XXX.XXX.XXX.XXX

 

RP Remote Port

XXXXX 500-65535

but 1000 and 2002

GW Gateway

XXX.XXX.XXX.XXX

 

EC End Char

XX represents the Hex Num. of ASCII. i.e 0D means CR

 

(Carrige Return)

FE Forward End Char

0-disabled, 1-enabled

EP Enable Serial Port Password

 

0-disabled, 1-enabled

CP Serial Port Password

 

XXXXXX maxim 16 characters

CC Connect CTRL

0-not used,1-RTS+,2-RTS-,3-CTS+,4-CTS_,5-RTS-CTS+,

 

6-RTS-CTS-, 7-DTS+,8-DTR-, 9-DCD/DSR+,

 

A-DCD/DSR-, B-DTR-DCD+, C-DTR-DCD-, D-RECONNECT

CT Connect Timeout

XXXXX 1-65535

 

WB Web Server

0-disable, 1-enable

Example:

 

 

 

To configure Baudrate 9600, 1 stop bit, Odd Parity, and RS232 mode. s -BD5 -PT1 -ST1 -MD0

Figure 4.17 Telnet Setup - iServer Help Page

27

Image 31
Contents User’s Guide Servicing North America OMEGAnet On-Line Service Internet e-mail Info@omega.comTable of Contents List of Tables Rear Panel View of i16 and i8 Series Meters withBefore You Begin Inspecting Your Shipment Customer ServiceManuals, Software Part Introduction Safety and EMC ConsiderationsEMC Considerations IServer on the Ethernet Network Part Hardware Physical Characteristics and MountingTB4 Network Communication Interface Section DIP Switches on the iServerSerial Communication Interfaces For Models with RS485 Port Data Transmission Characteristics RS485Half Duplex Hookup TB4 Pin# ILD Big Display Wiring RS485 InterfaceDevice # with RS485 Network Communication Interfaces 1 10Base-T RJ-45 Pinout RJ45 Pinout 2 10Base-T Crossover WiringNetwork Protocols Part Network ConfigurationEthernet MAC Address Dhcp DIP Switch on the iServer DNSIP Address Default IP AddressPort Number Part Operations Command Prefix Command Class MeaningLSB MSB Pinging eis03ec MS-DOS Prompt IServer Home Page Menu Device TypeRead Devices Device Setpoints Read DevicesDevice Setup Modify Device Parameters or Device List Entry Device Setup10 Configuration Serial Communication ConfigurationTerminal Server Device No. Refer to Section 11 Access Control Access Control3 4 OFF Access Control Host Name Refer to .4, DNS12 Access Control Setting a New IP Address over the NetworkTerminal Server Function 13 Terminal Server Configuration14 Terminal Emulation Terminal EmulationTera Term Telnet Connection Screen Telnet Setup17 Telnet Setup iServer Help \iServer\Httpget\httpget -r -S *01X01\r Httpget Program01X01074.3 ARP Protocol 18 ARP Commands and Responses19 PC-to-Device Communication Remote Access TunnelingRemote iServer 21 Configuration Menu Remote iServerUnder Terminal Server section, set Number of Connections to Local iServerMail Notifier Software InstallationEmail Connection Mapi Access Program Options Setup and Configuration25 iServer Mail Notifier Device Setting Device Setting and Configuration Device setup requiresInternal WEB Server Part Specifications Serial InterfaceNetwork Interface Processor CPUSerial Interface Network InterfaceAppendix a Glossary Appendix B IP Address Class C Appendix C IP NetmaskMask Dotted Notation Mask Binary Mask Bits Class a Class BDec Hex Binary Char No Parity No parity Appendix D Ascii ChartAscii Dec Hex BinaryDec Hex Ctrl Key Definition Char Equiv Appendix D Ascii Chart ContinuationAscii Control Codes Dec Hex Ctrl Key DefinitionPart Approvals Information CE Approvals Information WARRANTY/DISCLAIMER Shop on line at omega.com