6.0: Specification
All specifications are for a PSIM supplying a full network of probes.
|
|
| |
Input |
|
| |
Voltage |
| 85 to 264 Vac @ 47 Hz to 440 Hz. | |
Current |
| 0.8 A | |
Connection |
| via IEC320 connector | |
Isolation |
| 2500 Vac input/output | |
Protection |
| Input fuse and filter (not user replaceable) | |
Recommended Line Fuse | 2A T | ||
DC Output |
|
| |
Output Voltage |
| 5.1 Vdc Nominal | |
Output Current |
| 1.8 A max (i.e. 31 Orbit Modules) | |
Output Regulation | 3% (Line / Load) | ||
Transient Response | Max. 4% deviation recovers to 1% within 500 ms | ||
Ripple and Noise | < 1% | ||
Efficiency |
| 65% to 70% typical | |
Protection | see note 2 |
| |
Thermal Derating | The output current shall be derated from 40 °C | ||
|
|
| to 60 °C by 50%. (ie. Max. output at 60 °C |
|
|
| is 0.9A or 15 Orbit Modules.) |
|
|
|
|
| 13 |
| |
| |||
|
|
| |
|
|
|