7.0: Applications (continued)
PSIM-AC PSIM-DC PSIM-5V
Application 1: Basic Small Network Connection.
•Power supplied to network from PC via network card, no PSIM used.
•Modules connected using standard communication cables.
Volt drop total in mV | = | cable 1 + module (3 off) + cable 2 + module (3 off) |
| = (15.2 x 6) + 0.04(6+5+4+3+2+1) + (15.2 x 3) + 0.04(3+2+1) | |
| = | 138 mV |
Then approximate voltage at end of network | = | nominal supply voltage - calculated volt drop |
| = | 5.1 - 0.138 |
| = | 4.96 V |
|
|
|
|
| 19 |
| |
| |||
|
|
| |
|
|
|