Omega Vehicle Security LDN-PS manual Calculation for V1 volt drop, Calculation for V2 volt drop

Page 22

7.0: Applications (continued)

PSIM-AC PSIM-DC PSIM-5V

Volt drop V1 is calculated in a similar way to the previous example except there is only a single cable and 3 Orbit

modules. The PSIM supplies power to remaining modules and are calculated separately. The long communications cable does not carry supply current and so has no affect on volt drops.

Calculation for V1 volt drop

= cable + module (3 off)

 

= (15.2 x 3) + 0.04(3+2+1)

 

= 46 mV

Then approximate voltage at end of network

= nominal supply voltage - calculated volt drop

=5.1 - 0.046

=5.054 V

i.e. greater than 4.75 Vdc; the minimum working voltage.

Calculation for V2 volt drop

= PSIM + module (3 off)

 

= (5.3 x 3) + 0.04(3+2+1)

 

= 16 mV

Then approximate voltage at end of network

= nominal supply voltage - calculated volt drop

 

= 5.1 - 0.016

 

= 5.084 V

i.e. greater than 4.75 Vdc; the minimum working voltage.

 

 

 

 

LDN-PS

 

21

 

 

M-3340/1206

 

 

 

 

 

 

Image 22
Contents LDN-PS OMEGAnet On-Line Service Internet e-mail Info@omega.com Servicing North America Servicing EuropeDimensions and Mechanical Installation IndexIntroduction IntroductionSafety Information Service SafetySafety Information General Information Psim VariantsGeneral Information Psim General LayoutPsim used in a small network configuration Psim Schematic and Pin-out Psim Schematic and Pin-out PSIM-ACPSIM-DCPSIM-5V Dimensions and Mechanical InstallationPSIM-ACPSIM-DCPSIM-5V Power SupplyDimensions and Mechanical Installation PSIM-ACPSIM-DCPSIM-5V PsimInput SpecificationDC Output Reverse connection PSIM-AC PSIM-DC PSIM-5V Environmental ApprovalsApplications Volt drop Voltage Drop EstimationOrbit Module with T-CON Standard 2m Comms From no load output = 5.3 x N = 2 x N x L+1 mVApplication 1 Basic Small Network Connection Applications Calculation for V1 volt drop Calculation for V2 volt dropPSIM-AC PSIM-DCPSIM-5V Applications Application 4 Modules located a long distance from computer Application 5 Use with RS232 Interface Module RS232IM WARRANTY/DISCLAIMER OMEGA…Of Course