Omega Vehicle Security LDN-PS manual Introduction

Page 4

1.0: Introduction

PSIM-AC PSIM-DC PSIM-5V

Introduction

The Power Supply Interface Module (PSIM) is part of the Orbit Measurement System. The PSIM provides local power to the network when required. Example uses:

Power via the communications cable is not sufficient due to cable voltage drops.

The controlling computer is not suitable to supply the Orbit Network.

An RS232 Interface Module is used to control the Orbit Network.

This Manual

The manual describes the three types of PSIM. Technical specifications, safety information and application notes are detailed for each type.

PSIM-AC

PSIM-ACUniversal mains input to regulated 5V output. PSIM-DC10 - 30 Vdc input to regulated 5V output. PSIM-5V5 Vdc input (from user regulated supply).

Note:

Throughout this manual the Orbit System is referred to as requring a 5V power supply. For any applications, actual voltages or power supplies may be within the 4.75 to 5.25V range according to configuration. PSIM-AC and PSIM-DC has a nominal 5.1V output no load voltage. This allows for voltage drops across cables when Orbit Modules are added.

 

 

 

 

LDN-PS

 

3

 

 

M-3340/1206

 

 

 

 

 

 

Image 4
Contents LDN-PS OMEGAnet On-Line Service Internet e-mail Info@omega.com Servicing North America Servicing EuropeDimensions and Mechanical Installation IndexIntroduction IntroductionSafety Information Service SafetySafety Information General Information Psim VariantsGeneral Information Psim General LayoutPsim used in a small network configuration Psim Schematic and Pin-out Psim Schematic and Pin-out PSIM-ACPSIM-DCPSIM-5V Dimensions and Mechanical InstallationPSIM-ACPSIM-DCPSIM-5V Power SupplyDimensions and Mechanical Installation PSIM-ACPSIM-DCPSIM-5V PsimInput SpecificationDC Output Reverse connection PSIM-AC PSIM-DC PSIM-5V Environmental ApprovalsApplications Voltage Drop Estimation Orbit Module with T-CON Standard 2m CommsVolt drop From no load output = 5.3 x N = 2 x N x L+1 mVApplication 1 Basic Small Network Connection Applications Calculation for V1 volt drop Calculation for V2 volt dropPSIM-AC PSIM-DCPSIM-5V Applications Application 4 Modules located a long distance from computer Application 5 Use with RS232 Interface Module RS232IM WARRANTY/DISCLAIMER OMEGA…Of Course