Omega Vehicle Security LDN-PS manual Psim Schematic and Pin-out PSIM-ACPSIM-DCPSIM-5V

Page 11

4.0: PSIM Schematic and Pin-out (continued)PSIM-ACPSIM-DCPSIM-5V

View into plug

9 8 7 6

5 4 3 2 1

Connection to PSIM from Orbit Network

Plug Pin-out

1 = No connection

2 = RS485 (A)

3 = RS485 (B)

4 = 0V

5 = 0V

6 = No connection (no pin)

7 = No connection (no pin)

8 = No connection (no pin)

9 = 0V

shell = case / 0V

 

View into socket

Socket Pin-out

 

 

 

 

 

 

1 = No connection

 

 

 

 

 

 

6

7

8

9

 

2 = RS485 (A)

 

 

 

 

 

 

3 = RS485 (B)

 

 

 

 

 

 

4 = 0V

 

 

 

 

 

 

5 = 0V

1

2 3

4

5

6 = +5V

 

 

 

 

 

 

7 = +5V

Connection from PSIM to

8 = +5V

9 = 0V

 

Orbit Network

shell = case / 0V

The PSIM will only supply power to the Orbit Modules that follow the PSIM. Some typical configurations are shown. For more information about PSIM and Orbit Network connection, refer to the Applications section.

Orbit Modules are designed to work from a supply voltage of 4.75 to 5.25 Vdc and care must be taken to ensure that all modules have the right working voltage applied. See application notes.

 

 

 

 

LDN-PS

 

10

 

 

M-3340/1206

 

 

 

 

 

 

Image 11
Contents LDN-PS Servicing North America Servicing Europe OMEGAnet On-Line Service Internet e-mail Info@omega.comIndex Dimensions and Mechanical InstallationIntroduction IntroductionService Safety Safety InformationSafety Information Psim Variants General InformationPsim General Layout General InformationPsim used in a small network configuration Psim Schematic and Pin-out Psim Schematic and Pin-out PSIM-ACPSIM-DCPSIM-5V Power Supply Dimensions and Mechanical InstallationPSIM-ACPSIM-DCPSIM-5VPsim Dimensions and Mechanical Installation PSIM-ACPSIM-DCPSIM-5VDC Output SpecificationInput Reverse connection PSIM-AC PSIM-DC PSIM-5V Approvals EnvironmentalApplications From no load output = 5.3 x N = 2 x N x L+1 mV Voltage Drop EstimationOrbit Module with T-CON Standard 2m Comms Volt dropApplication 1 Basic Small Network Connection Applications Calculation for V2 volt drop Calculation for V1 volt dropPSIM-AC PSIM-DCPSIM-5V Applications Application 4 Modules located a long distance from computer Application 5 Use with RS232 Interface Module RS232IM WARRANTY/DISCLAIMER OMEGA…Of Course