ProSafe VPN Firewall 200 FVX538 Reference Manual
Restoring the Default Configuration and Password
This section explains how to restore the factory default configuration settings, changing the firewall’s administration password to password and the IP address to 192.168.1.1. You can erase the current configuration and restore factory defaults in two ways:
•Use the Erase function of the firewall (see “Backup and Restore Settings” on page
•Use the reset button on the rear panel of the firewall. Use this method for cases when the administration password or IP address is not known.
To restore the factory default configuration settings without knowing the administration password or IP address, you must use the reset button on the rear panel of the firewall.
To restore the factory defaults:
1.Press and hold the reset button until the Test LED turns on and begins to blink (about 10 seconds).
2.Release the reset button and wait for the firewall to reboot.
Problems with Date and Time
The
•Date shown is January 1, 2000. Cause: The firewall has not yet successfully reached a Network Time Server. Check that your Internet access settings are configured correctly. If you have just completed configuring the firewall, wait at least five minutes and check the date and time again.
•Time is off by one hour. Cause: The firewall does not automatically sense Daylight Savings Time. Check the Time Zone menu, and check or uncheck the box marked “Adjust for Daylight Savings Time”.
Troubleshooting |
v1.0, August 2006