ProSafe VPN Firewall 200 FVX538 Reference Manual
•Ping to this IP address – Enter a public IP address that will not reject the Ping request or will not consider the traffic abuse. Queries are sent to this server through the WAN interface being monitored.
5.Enter a Test Period in seconds. DNS query is sent periodically after every test period. The default test period is 30 seconds.
Figure
6.Enter the Maximum Failover amount. The WAN interface is considered down after the configured number of queries have failed to elicit a reply. The rollover link is brought up after this. The Failover default is 4 failures.
The default time to roll over after the primary WAN interface fails is 2 minutes (a
7.Click Apply to save your settings.
8.Click Reset to revert to the previous settings.
Once a rollover occurs, an alert will be generated (see
Connecting the FVX538 to the Internet |