Multi-Tech Systems MT5634ZBA-V-V92 manual Troubleshooting, None of the Indicators Light

Page 24

Chapter 7 – Troubleshooting

Chapter 7 – Troubleshooting

Your modem was thoroughly tested at the factory before it was shipped. If you are unable to make a successful connection, or if you experience data loss or garbled characters during your connection, it is possible that the modem is defective. However, it is more likely that the source of your problem lies elsewhere. The following symptoms are typical of problems you might encounter:

None of the LEDs light when the modem is on.

The modem does not respond to commands.

The modem cannot connect when dialing.

The modem disconnects while online.

The modem cannot connect when answering.

File transfer is slower than it should be.

Data is being lost.

There are garbage characters on the monitor.

The modem doesn’t work with Caller ID.

Fax and data software can’t run at the same time.

If you experience problems, please check the following possibilities before calling Technical Support (see Appendix F).

None of the Indicators Light

When you turn on the modem, the LED indicators on the front panel should flash briefly as the modem runs a self-test. If the LEDs remain off, the modem is probably not receiving power.

Make sure the modem’s power switch is on, especially if you normally turn the modem on by turning on a power strip.

If the modem is plugged into a power strip, make sure the power strip is plugged in and its power switch is on.

Make sure the power supply is firmly connected to the modem and the power supply’s power cord is firmly connected to both to the power supply and the wall outlet or power strip.

If the power strip is on and the modem switch is on, try moving the power supply to another outlet on the power strip.

Test that the outlet is live by plugging another device, such as a lamp, into it.

The modem or power supply may be defective. If you have another Multi-Tech modem, try swapping modems. If the problem goes away, the first modem or power supply might be defective. Call Technical Support for assistance.

CAUTION: Do not under any circumstances replace the power supply with one designed for another product; doing so can damage the modem and void your warranty.

The Modem Does Not Respond to Commands

Make sure the modem is plugged in and turned on. (See “None of the Indicators Light.”)

Make sure you are issuing the modem commands from data communication software, either manually in terminal mode or automatically by configuring the software. (You cannot send commands to the modem from the DOS prompt.)

Make sure you are in terminal mode in your data communication program, the TR LED should be lit, then type AT and press ENTER. If you get an OK response from your modem, your connections are good and the problem likely is in the connection setup in your communication software.

Try resetting your modem by turning it off and on. If you are using DOS or Windows 3.1 communication software, make sure the initialization string includes &F as the first command, to cancel any “leftover’ command that could affect the modem’s operation.

If you don’t get an OK, the problem may still be in the communication software. Make sure you have done whatever is necessary in your software to make a port connection. Not all communication programs connect to the COM port automatically. Some connect when the software loads and remain connected until the program terminates. Others can disconnect without exiting the program. The modem’s TR indicator lights to show that the software has taken control of the modem through the COM port.

Multi-Tech Systems, Inc. MT5634ZBA-Series User Guide (S000286G)

24

Image 24
Contents MultiModem ZBA MultiModem ZBA MT5634ZBA-Series User Guide Table of Contents Table of Contents Features Table IntroductionFeatures Specific to Installation Safety WarningsChange the Internal Jumpers Opening the ModemChanging the Voice Jumper Connect the Modem to Your PC Global ConnectionsNon-Global Connection Connect the Two-Wire Leased Line Leased Line Only Connect the Modem to the AC Power OutletPower-On Test Connect the Modem to Your PCInstall the Modem Driver Installing the Modem DriverUsing the Global Wizard to Configure Your Modem Using AT Commands to Configure Your ModemConfigure the modem for best performance Modem Serial Speed GuidelinesOperation About the Front PanelSetup Leased-Line OperationOperation Connecting to the Internet AT Commands, S- Registers, and Result Codes Remote Configuration Basic ProcedureSetup Changing the Setup PasswordChanging the Setup Password Callback SecurityTurning Callback Security On and Off Setting Callback Security Message Parity Assigning Callback Passwords and Phone NumbersCalling Procedures Password-Only CallbackNumber-Entry Callback Extension-Entry CallbackCallback Security Commands Direct ConnectionCallback Assignments Form Troubleshooting None of the Indicators LightModem Does Not Respond to Commands Lack of a physical connection to the telephone line Page Data Is Being Lost There Are Garbage Characters on the MonitorModem Doesn’t Work with Caller ID Fax and Data Software Can’t Run at the Same TimeAppendix a Technical Specifications Fax Data RatesReceiver Sensitivity Upgrade Overview Appendix B Upgrading the Modem’s FirmwareIdentify the Modem Firmware Identify the Current Firmware VersionDownload the Upgrade File Extract the Upgrade FilesUpgrade the Modem’s Firmware Restore Your ParametersAppendix C Regulatory Compliance FCC Part 15 RegulationFCC Part 68 Telecom EMC, Safety and R&TTE Directive Compliance Canadian Limitations NoticeIndustry Canada International Modem RestrictionsNew Zealand Telecom Warning Notice South African StatementAppendix D Waste Electrical and Electronic Equipment Weee Waste Electrical and Electronic Equipment StatementAppendix E Installing a Modem under Linux SetupAppendix F Connecting to a Cisco Router Connecting to a Cisco Router Console PortRemote Configuration Console Port ConnectionsAppendix G Warranty, Service, and Technical Support Multi-Tech Warranty StatementRepair Procedures for International Distributors Appendix H Rohs HT/TS Substance Concentration AT commands IndexSpeed