Multi-Tech Systems MT5634ZBA-V-V92 manual Lack of a physical connection to the telephone line

Page 25
Chapter 7 – Troubleshooting
Your communication software settings may not match the physical port to which the modem is connected. The serial cable might be plugged into the wrong connector—check your computer documentation to make sure. Or you might have selected a COM port in your software other than the one the modem is physically connected to—compare the settings in your software to the physical connection.
If the modem is on, the cable is plugged into the correct port, the communication software is configured correctly, and you still don’t get an OK, the fault might be in the serial cable. Make sure it is firmly connected at both ends.
Is this the first time you have used the cable? If so, it may not be wired correctly. Check the cable description on the packaging to make sure the cable is the right one for your computer.
Peripheral expansion cards, such as sound and game cards, might include a serial port preconfigured as COM1 or COM2. The extra serial port, or the card itself, may use the same COM port, memory address, or interrupt request (IRQ) as your communication port. Be sure to disable any unused ports.
Windows 9x: Right-click on My Computer, select Properties from the menu, click on the Device Manager tab, double-click on Ports, then double-click on the communication port your modem is connected to. In the port’s Properties sheet, click on the Resources tab to see the port’s input/output range and interrupt request. If another device is using the same address range or IRQ, it appears in the Conflicting Device List. Uncheck Use automatic settings to change the port’s settings so they do not conflict with the other device, or select the port the conflicting device is on and change it instead. If you need to open your computer to change switches or jumpers on the conflicting device, refer to the device’s documentation.
Windows NT 4.0: To look for address or IRQ conflicts, click Start, Programs, Administrative Tools (Common), and Windows NT Diagnostics. In the Windows NT Diagnostics dialog box, click the Resources tab to see which input/output ranges and interrupt requests are in use. If you need to open your computer to change switches or jumpers on the conflicting device, refer to the device’s documentation.
The serial port might be defective. If you have another serial port, install the modem on it, change the COM port setting in your software, and try again.
The modem might have a problem beyond the scope of this user guide. If you have another Multi-Tech modem, try the other modem (if there is no problem with the other modem, call Technical Support for assistance. See Appendix F for phone numbers).
The Modem Cannot Connect When Dialing
There can be several reasons the modem fails to make a connection. Possibilities include

lack of a physical connection to the telephone line.

a wrong dial tone.

a busy signal.

a wrong number.

no modem at the other end.

a faulty modem, computer, or software at the other end.

incompatibility between modems

poor line conditions.

You can narrow the list of possibilities by using extended result codes. Extended result codes are enabled by default. If they have been disabled, include V1X4 in the modem’s initialization string, or in terminal mode enter ATV1X4 and press ENTER. When you dial again, the modem reports the call’s progress.

If the modem reports NO DIALTONE, check that the modem’s telephone line cable is connected to both the modem’s LINE jack (not the PHONE jack) and the telephone wall jack. If the cable looks secure, try replacing it. If that doesn’t work, the problem might be in your building’s telephone installation. To test the building installation, plug a telephone into your modem’s telephone wall jack and listen for a dial tone. If you hear a dial tone, your modem might be installed behind a corporate phone system (PBX) with an internal dial tone that sounds different from the normal dial tone. In that case, the modem might not recognize the dial tone and might treat it as an error. Check your PBX manual to see if you can change the internal dial tone. If you can’t, change your modem’s initialization string to replace X4 with X3, which will cause the modem to ignore dial tones.

If the modem reports BUSY, the other number might be busy, in which case you should try again later. However, it might indicate that you have failed to add a 9, the prefix to the phone number if you must dial 9 for an outside line.

If you must dial 9 to get an outside line, the easiest way to dial it automatically is to include it in the modem’s dial prefix; e.g., ATDT9. Note the comma, which inserts a pause before the number is dialed. By inserting 9, into the dial prefix, you do not have to include it in each directory entry.

To change the dial prefix in Windows HyperTerminal, select Connect from the Call menu, click Dialing Properties, and type 9 in the local and long distance boxes in How I dial from this location.

Multi-Tech Systems, Inc. MT5634ZBA-Series User Guide (S000286G)

25

Image 25
Contents MultiModem ZBA MultiModem ZBA MT5634ZBA-Series User Guide Table of Contents Table of Contents Introduction Features TableFeatures Specific to Safety Warnings InstallationChange the Internal Jumpers Opening the ModemChanging the Voice Jumper Global Connections Connect the Modem to Your PCNon-Global Connection Connect the Modem to the AC Power Outlet Connect the Two-Wire Leased Line Leased Line OnlyPower-On Test Connect the Modem to Your PCInstalling the Modem Driver Install the Modem DriverUsing AT Commands to Configure Your Modem Using the Global Wizard to Configure Your ModemModem Serial Speed Guidelines Configure the modem for best performanceAbout the Front Panel OperationLeased-Line Operation SetupOperation Connecting to the Internet AT Commands, S- Registers, and Result Codes Basic Procedure Remote ConfigurationSetup Changing the Setup PasswordCallback Security Changing the Setup PasswordTurning Callback Security On and Off Assigning Callback Passwords and Phone Numbers Setting Callback Security Message ParityCalling Procedures Password-Only CallbackExtension-Entry Callback Number-Entry Callback Direct Connection Callback Security CommandsCallback Assignments Form None of the Indicators Light TroubleshootingModem Does Not Respond to Commands Lack of a physical connection to the telephone line Page There Are Garbage Characters on the Monitor Data Is Being LostModem Doesn’t Work with Caller ID Fax and Data Software Can’t Run at the Same TimeFax Data Rates Appendix a Technical SpecificationsReceiver Sensitivity Appendix B Upgrading the Modem’s Firmware Upgrade OverviewIdentify the Modem Firmware Identify the Current Firmware VersionExtract the Upgrade Files Download the Upgrade FileUpgrade the Modem’s Firmware Restore Your ParametersFCC Part 15 Regulation Appendix C Regulatory ComplianceFCC Part 68 Telecom Canadian Limitations Notice EMC, Safety and R&TTE Directive ComplianceIndustry Canada International Modem RestrictionsSouth African Statement New Zealand Telecom Warning NoticeWeee Waste Electrical and Electronic Equipment Statement Appendix D Waste Electrical and Electronic EquipmentSetup Appendix E Installing a Modem under LinuxConnecting to a Cisco Router Console Port Appendix F Connecting to a Cisco RouterConsole Port Connections Remote ConfigurationMulti-Tech Warranty Statement Appendix G Warranty, Service, and Technical SupportRepair Procedures for International Distributors Appendix H Rohs HT/TS Substance Concentration Index AT commandsSpeed