Multi-Tech Systems MT5600BAV.90, MT5600BLV.90, MT5600BAV.92 manual Ing strings have been entered

Page 37

Chapter 6 - Callback Security

7. Press the Enter button again to go to the PASSWORD SETUP screen.

8.Press , to go to the ENTER PASSWORD #2? screen.

9.Repeat steps 3–7 to enter the next password.

10.Repeat as many times as necessary, up to memory location 30, until all pass- words have been entered.

Warning: There is no way to review an entry to confirm that it has been entered cor- rectly. If you attempt to look at a password entry by pressing the Enter button for an

￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿ENTER PASSWORD #n? screen, it is possible to accidentally erase the entry.

1.Open a data communication program, such as HyperTerminal.

2.To store a callback phone number in the first memory location, type AT#CBN01=xxxxxxxxxx, where xxxxxxxxxx is the dialing string, and press ENTER. The dialing string can include the digits 0 through 9 and any of the following char- acters: #, *, comma (,), semicolon (;), W, A, B, C, and D. Up to 30 characters can be used. Example: AT#CBN01=9,16127853000. If a direct connection with pass- word protection, but without hangup and callback, is desired, the first character in the dialing string should be a hyphen (-).

3.To store a callback phone number in the second memory location, type AT#CBN02=xxxxxxxxxx, where xxxxxxxxxx is the dialing string, and press ENTER. Note that the memory location number in the command is incremented by one.

4.Repeat as many times as necessary, through memory location 30, until all dial-

￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿ing strings have been entered.

1.Turn on the modem.

2.Starting at the STATUS screen, press the following buttons on the front panel: , , , , , , , , . The ENTER NUMBER #1? screen appears.

3.Press the Enter button on the front panel to select memory location 1. The ENTER NUMBER screen appears.

4.Press the or button several times to select the first character. If a direct connection, without hangup and callback, is desired, the first character in the di- aling string should be a hyphen (-).

5.Press the button to go to the next character in the dialing string. Note: To backspace or to cancel an entry, press several times.

6.The number can be up to 30 characters in length. Repeat steps 4 and 5 until the number is entered, and then press the Enter button to store it. The NUMBER STORED screen should appear.

7. Press the Enter button again to go to the CALLBACK NUMBER screen.

Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide

37

Image 37
Contents MT5600BA/BL Series Revision Date Description Table of Contents Contents General Description and Features Telephone systems Wall jack Installation$#%#8. Click Finish to exit +,-./0$1Chapter 2 Installation 345 Using the Front Panel Front panel Using the Front PanelTrunks LimbsTwigs Limbs Branches Twigs From previous Limbs Branches Twigs Using the Front Panel Limb Branches Twigs Using the Front Panel Using the Front Panel Multi-Tech Systems, Inc. MT5600BA/BL Series User Guide Using the Front Panel Using the Front Panel Using the Front Panel Ters, press the 〈 and  buttons. To go to the next position Using the Front Panel Leased Line Operation Leased Line Operation Leased Line Operation Leased Line Operation Remote Configuration Remote Configuration Modem you must use the new passwordCallback Security Callback Security AvailableIng strings have been entered Callback Security Callback Enable/Disable # Callback Security Troubleshooting Troubleshooting Assistance see Appendix D TroubleshootingTroubleshooting Troubleshooting Troubleshooting Appendix a Regulatory Compliance Appendix a Regulatory Compliance Modem to become non-compliant Exceed Command Buffer CommandsError Correction Mode of OperationConnectors Appendix B Technical SpecificationsDiagnostics IndicatorsAppendix C Warranty,Service, and Technical Support Sep-01 DEFAULT.ASP Appendix C Warranty, Service, and Technical SupportEtc Restore your parameters Not 6.xx firmware Close the terminal program Com4 ttyS3 Appendix E Installing a Modem Under Linux Using the Modem to Call the InternetAppendix F Pin Descriptions RDL Appendix F Pin DescriptionsFig. F-4. Two-wire leased line cable Index IndexSerial cable Windows