Multi-Tech Systems MT2834BA Series manual Appendix F Regulatory Information, FCC Part 68 Telecom

Page 114

Appendix F - Regulatory Information

Appendix F - Regulatory Information

FCC Part 15

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Plug the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

This device complies with Part 15 of the FCC rules. Operation of this device is subject to the following conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference that may cause undesired operation.

WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Industry Canada

This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe B respecte toutes les exigences du Reglement Canadien sur le matériel brouilleur.

FCC Part 68 Telecom

1.This equipment complies with part 68 of the Federal Communications Commission Rules. On the outside surface of this equipment is a label that contains, among other information, the FCC registration number. This information must be provided to the telephone company.

2.The suitable USOC jack (Universal Service Order Code connecting arrangement) for this equipment is shown below. If applicable, the facility interface codes (FIC) and service order codes (SOC) are shown.

3.An FCC-compliant telephone cord and modular plug is provided with this equipment. This equipment is designed to be connected to the telephone network or premises wiring using a compatible modular jack that is Part 68 compliant. See installation instructions for details.

4.The ringer equivalence number (REN) is used to determine the number of devices that may be connected to the telephone line. Excessive RENs on the telephone line may result in the device not ringing in response to an incoming call. In most, but not all, areas the sum of the RENs should not exceed 5.0. To be certain of the nuber of devices that may be connected to the line, as determined by the total RENs, contact the local telephone company.

5.If this equipment causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. But if advance notice is not practical, the telephone company will notify you as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary.

6.The telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the operation of the equipment. If this happens, the telephone company will provide advance notice in order for you to make necessary modifications in order to maintain uninterrupted service.

7.If trouble is experienced with this equipment (the model of which is indicated below) please contact Multi-Tech Systems, Inc. at the address shown below for details of how to have repairs made. If the trouble is causing harm to the telephone network, the telephone company may request you remove the equipment from the network until the problem is resolved.

8.No repairs are to be made by you. Repairs are to be made only by Multi-Tech Systems or its licensees. Unauthorized repairs void registration and warranty.

9.This equipment should not be used on party lines or coin lines.

10.If so required, this equipment is hearing-aid compatible.

11.Manufacturer: Multi-Tech Systems, Inc.

Trade Name:

MultiModem

Model Number:

MultiModemBA and MultiModemBL

FCC Registration No:

AU7USA-65363-MD-E and AU7USA-20673-MM-E

Ringer Equivalence No:

0.5B and 0.3B

Modular Jack (USOC):

RJ-11C or RJ-11W (single line)

Service Center in USA:

Multi-Tech Systems, Inc.

 

 

2205 Woodale Drive

 

 

Mounds View, MN 55112 U.S.A.

 

 

(763) 785-3500

 

 

(763) 785-9874 Fax

Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide

114

Image 114
Contents User Guide Patents User GuideRecord of Revisions Date Description TrademarksContents Registers Index 117Introduction and Description How To Use This Manual IntroductionModem Features 1 MT2834BA/BL Series Features Fax FeaturesTechnical Specifications Power Modem LED Indicators MT2834BA LED DisplayControls on PC Board Installation and Connection Safety Warnings What Is in Your Modem Package?Installation Installation ProcedureMultiModemBA Connections Installing PhoneTools, the Data Communications Software Is Your Modem Ready for Use?Software Configuration and Modem Basics Software Configuration Configuring Your SoftwareConfiguring Software for Your Modem PC Initialization StringsOther Parameters Changing Default ParametersConfiguring Software for Your Computer AT &F S0=0 &F9 &W0 CRAnswer/Originate Voice/Data Toggle Switch Modem BasicsSimple Operations Manual Dial and Automatic Answer Dialing/On-Line/Answering Manual Dial and Automatic AnswerManual Dial Backup Call Termination Dial Backup and Leased Line RestoralAutomatic Leased Line Restoral Operation Dial-Up Operation Manual Call OriginationAutomatic Answering Manual AnsweringAbort Timer Handshaking DetailsCall Termination Command Mode AT Command Editing Command ModeFunctional Modes Summary of AT Commands Functional ModesStore Modem Configure Data Result Codes Multi-Tech Result CodesStandard AT Result Codes Dialing Commands Dialing Action CommandsPulse or Tone Dial P T Dial Modifier CommandsVoice/Data Dialing $VD Set Pulse Dial Ratios &PAutomatic Pauses in Dialing Return to Command Mode After Dial Command ExecutionReverse the Mode of Operation R Long Space Disconnect YCalling Card Detect Tones $ Quiet Answer @Number Linking NN Phone Number Memory CommandsStoring Phone Numbers D...N Listing Numbers Stored in Memory LConfiguration and Default Storage Commands Loading Factory Defaults &FModem Reset Z Async/Sync Mode Switching &M Unix Uucp Spoofing $SPSynchronous Transmit Clock Select &X Result Codes Enable/Disable and No Response Answer Q Command Response Result Code CommandsEcho Command Mode Characters E Result Codes Multi-Tech or Standard AT &QResult Codes Basic and Extended and Call Progress Selection Guard Tones Not Used in BAI/BLI Models &G Phone Line Conditioning CommandsEnable/Disable Trelis Coded Modulation #T Bell/V.21 ToneCleardown at Disconnect &CD Fallback Modes When On-Line #FEnable/Disable Lowspeed Fast Connect $FC Auto Speed Detect #AData Terminal Ready Control &D 7 RS-232C Interface Control CommandsCarrier Detect Control &C CTS Control &RData Set Ready Control &S CTS/RTS Interaction Control &RFDSR/CD Interaction Control &SF Auto-Reliable Mode &E1 Error Correction CommandsNormal Mode &E0 Reliable Mode &E2Mode Select #L Auto-Reliable Buffering $AEnable/Disable Auto Reliable Fallback Character $F Error Correction/300bps $ERetransmit Count $R Flow Control Commands Hardware Flow Control &E4Xon/Xoff Flow Control &E5 Xon/Xoff Pass-Through &E7 Send Xon/Xoff Characters #XHewlett-Packard ENQ/ACK Pacing &E9 Maximum Block Size &BS Normal Mode Modem Flow Control On &E11Terminal/Computer Initiated Pacing &E13 Parity Selection #PNormal/Auto-Reliable/Reliable Mode Commands Xon/Xoff Pass-Through CommandsEnq/Ack Pacing Commands Speed Conversion Commands Speed Conversion $BAModem Baud Rate $MB Serial Port Baud Rate $SB Immediate Action Commands Listing On-Line Diagnostics L8 Off Hook HLine Probe Commands Force Answer Mode aExiting Command Mode, Going Back On-Line O Registers Escape Code Character Number of Rings Until Modem AnswersRings Which Have Occurred Return CharacterBackspace Character Time for Carrier Abort TimerLine Feed Character Wait Time for Dial ToneCarrier Detect Response Time S10 Carrier Loss Disconnect Delay TimeS13 Remote Configuration Escape Character S11 Tone Dialing Tone Spacing and DurationS16 Callback Attempts S15 Callback Time DelayS19 MT2834BL Only Dial-Back Timer S17 Changing Break TimeS24 PBX/CBX Disconnect Drop Time for DSR/CTS/CD S26 Failed Password AttemptsS29 Local Inactivity Timer S25 DTR Dropout TimeS36 Time Between DTR Inactive and Modem Off-Hook S30 Inactivity TimerS32 Time Elapse for Escape Sequence S37 Time Between DTR Active and Modem On-HookS48 Program V.34bis Connect Speeds Reading and Assigning S-Register Values Examples of Assigning ValuesExamples of Reading Values AT Command and S-Register Summary Callback Security and Remote Configuration Callback Feature Description Callback Security and Remote ConfigurationRemote Configuration Description To change your Remote Configuration feature statusTo set parity of the password/message prompt AT#CBN0xxxxxxxxxxCRCallback Operational Sequence Procedures Remote Configuration Procedures Remote Configuration Operation ProceduresRemote Configuration and Callback Security AT Commands Remote Configuration/Callback Security S-Registers DIP-Switch Settings Dip-Switch Settings MT2834BA PC BoardDIP-Switch Option Settings Switch #4 AS/400 Mode Synchronous Mode/Leased Line/Dial-UP = Down Down Dip-Switch Settings Speaker Volume Control Recording Option Configurations Switch Function Position EffectDIP Switches #13-14 DIP Switches #15-16 MT2834BADIP Switches #15-16 MT2834BL Warranty, Service and Tech Support Multi-Tech Systems, Inc. Warranty & Repairs Policies Warranty, Service, and Technical SupportOnline Warranty Registration Repair Procedures for International DistributorsInternet Sites Replacement PartsTechnical Support Country TelephoneAppendixes Upgrade Overview Appendix a Upgrading Your Modem’s FirmwareAppendix a Upgrading Your Modem’s Firmware Download the Upgrade File Upgrade the Modem’s Firmware Modem Does Not Respond to Commands Appendix B TroubleshootingNone of the LEDs Light When the Modem Is On Appendix B TroubleshootingAppendix B Troubleshooting Modem Dials But Cannot Make a Connection File Transfer Is Slower Than It Should Be Modem Cannot Connect When AnsweringModem Disconnects While On-line Am Losing DataAm Getting Garbage Characters on the Monitor Appendix C AT Command Summary Appendix C AT Command SummaryCommand Values Description DsNd Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 100$FCn MT2834BL Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 101$MBn Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 102$SBn Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 103Dial Tone Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 104Callback Security/Remote Configuration Command Summary Password Command Summary 25bis Commands25bis Operation Delayed and Forbidden NumbersAppendix D V.25bis Operation Appendix D V.25bis Operation25bis Set-Up and Initialization 25bis Mode AT Commands25bis DIP-Switches Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 108Change Serial Baud Rate CSP Command 25bis AT CommandsEnable/Disable V.25bis Mode $V Command 25bis Responses Result CodesListing Forbidden Phone Number RLF Command Dial Phone Number Provided CRN CommandListing Delayed Phone Numbers RLD Command Disregard or Connect to Incoming Calls DIC or CIC CommandITU V.25bis Country Specific Information Appendix D V.25bis Operation Belgium SingaporeMulti-Tech Systems, Inc. MT2834BA/BL Series User Guide 112 Appendix E MultiModemBA Cables Appendix E MultiModemBA/BL CablesAppendix F Regulatory Information FCC Part 68 TelecomFCC Part Canadian Limitations Notice Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 115South African Notice Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 116Appendix G Weee Statement Index Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 11791-116 Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 118PBX/CBX Disconnect Drop Time for DSR/CTS/CD63 Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 119