Multi-Tech Systems MT2834BA Series manual S15 Callback Time Delay, S16 Callback Attempts

Page 62

Chapter 6 - S-Registers

S15

Callback Time Delay

Unit:

Seconds

Range:

10-255

Default:

20

Description:

S15 defines the time delay between Callback attempts after initial passwords have

 

been exchanged between modems.

S16

Callback Attempts

Unit:

1 Attempt

Range:

1-255

Default:

4

Description:

S16 defines the number of attempts allowed after initial passwords have been

 

exchanged between modems.

S17

Changing Break Time

Unit:

10 mSec.

Range:

0-2.5 sec

Default:

250

Description:

S17 defines the break time (space) sent to the local PC. The default is set for a 25 to

 

250 mSec break. The break time can be changed in 10 mSec increments by

 

increasing or decreasing the value of S17.

S18 (MT2834BL Only)

Automatic Leased Line Restoral

Unit:

1 minute

Range:

10-255

Default:

30 minutes

Description:

When the modem is in dial backup mode, it periodically checks the lease line to see

 

if it is operational and tries to restore the lease line if possible. S18 defines how often

 

attempts occur. The default of S18 is 30 minutes and can be set in one minute

 

increments from 10 to 255 minutes. Setting the S18 restoral under 10 minutes

 

causes excessive breaks in dial-up operation.

S19 (MT2834BL Only)

Dial-Back Timer

Unit:

1 minute

Range:

0-255

Default:

1

Description:

S19 is a timer that begins when the lease line goes down. S19 specifies the duration

 

of time the modem attempts to reestablish the lease line connection.

*Value for International and DOC units

**Value for International units only

Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide

62

Image 62
Contents User Guide Patents User GuideRecord of Revisions Date Description TrademarksContents Registers Index 117Introduction and Description How To Use This Manual IntroductionModem Features 1 MT2834BA/BL Series Features Fax FeaturesTechnical Specifications Power Modem LED Indicators MT2834BA LED DisplayControls on PC Board Installation and Connection Safety Warnings What Is in Your Modem Package?Installation Installation ProcedureMultiModemBA Connections Installing PhoneTools, the Data Communications Software Is Your Modem Ready for Use?Software Configuration and Modem Basics Software Configuration Configuring Your SoftwareConfiguring Software for Your Modem PC Initialization StringsOther Parameters Changing Default ParametersConfiguring Software for Your Computer AT &F S0=0 &F9 &W0 CRSimple Operations Answer/Originate Voice/Data Toggle SwitchModem Basics Manual Dial and Automatic Answer Dialing/On-Line/Answering Manual Dial and Automatic AnswerAutomatic Leased Line Restoral Operation Manual Dial Backup Call TerminationDial Backup and Leased Line Restoral Dial-Up Operation Manual Call OriginationAutomatic Answering Manual AnsweringCall Termination Abort TimerHandshaking Details Command Mode Functional Modes AT Command EditingCommand Mode Summary of AT Commands Functional ModesStore Modem Configure Data Standard AT Result Codes Result CodesMulti-Tech Result Codes Dialing Commands Dialing Action CommandsPulse or Tone Dial P T Dial Modifier CommandsVoice/Data Dialing $VD Set Pulse Dial Ratios &PAutomatic Pauses in Dialing Return to Command Mode After Dial Command ExecutionReverse the Mode of Operation R Long Space Disconnect YCalling Card Detect Tones $ Quiet Answer @Number Linking NN Phone Number Memory CommandsStoring Phone Numbers D...N Listing Numbers Stored in Memory LModem Reset Z Configuration and Default Storage CommandsLoading Factory Defaults &F Synchronous Transmit Clock Select &X Async/Sync Mode Switching &MUnix Uucp Spoofing $SP Result Codes Enable/Disable and No Response Answer Q Command Response Result Code CommandsEcho Command Mode Characters E Result Codes Multi-Tech or Standard AT &QResult Codes Basic and Extended and Call Progress Selection Guard Tones Not Used in BAI/BLI Models &G Phone Line Conditioning CommandsEnable/Disable Trelis Coded Modulation #T Bell/V.21 ToneCleardown at Disconnect &CD Fallback Modes When On-Line #FEnable/Disable Lowspeed Fast Connect $FC Auto Speed Detect #AData Terminal Ready Control &D 7 RS-232C Interface Control CommandsCarrier Detect Control &C CTS Control &RDSR/CD Interaction Control &SF Data Set Ready Control &SCTS/RTS Interaction Control &RF Auto-Reliable Mode &E1 Error Correction CommandsNormal Mode &E0 Reliable Mode &E2Mode Select #L Auto-Reliable Buffering $ARetransmit Count $R Enable/Disable Auto Reliable Fallback Character $FError Correction/300bps $E Xon/Xoff Flow Control &E5 Flow Control CommandsHardware Flow Control &E4 Hewlett-Packard ENQ/ACK Pacing &E9 Xon/Xoff Pass-Through &E7Send Xon/Xoff Characters #X Maximum Block Size &BS Normal Mode Modem Flow Control On &E11Terminal/Computer Initiated Pacing &E13 Parity Selection #PEnq/Ack Pacing Commands Normal/Auto-Reliable/Reliable Mode CommandsXon/Xoff Pass-Through Commands Modem Baud Rate $MB Speed Conversion CommandsSpeed Conversion $BA Serial Port Baud Rate $SB Immediate Action Commands Listing On-Line Diagnostics L8 Off Hook HExiting Command Mode, Going Back On-Line O Line Probe CommandsForce Answer Mode a Registers Escape Code Character Number of Rings Until Modem AnswersRings Which Have Occurred Return CharacterBackspace Character Time for Carrier Abort TimerLine Feed Character Wait Time for Dial ToneCarrier Detect Response Time S10 Carrier Loss Disconnect Delay TimeS13 Remote Configuration Escape Character S11 Tone Dialing Tone Spacing and DurationS16 Callback Attempts S15 Callback Time DelayS19 MT2834BL Only Dial-Back Timer S17 Changing Break TimeS24 PBX/CBX Disconnect Drop Time for DSR/CTS/CD S26 Failed Password AttemptsS29 Local Inactivity Timer S25 DTR Dropout TimeS36 Time Between DTR Inactive and Modem Off-Hook S30 Inactivity TimerS32 Time Elapse for Escape Sequence S37 Time Between DTR Active and Modem On-HookS48 Program V.34bis Connect Speeds Examples of Reading Values Reading and Assigning S-Register ValuesExamples of Assigning Values AT Command and S-Register Summary Callback Security and Remote Configuration Callback Feature Description Callback Security and Remote ConfigurationRemote Configuration Description To change your Remote Configuration feature statusTo set parity of the password/message prompt AT#CBN0xxxxxxxxxxCRCallback Operational Sequence Procedures Remote Configuration Procedures Remote Configuration Operation ProceduresRemote Configuration and Callback Security AT Commands Remote Configuration/Callback Security S-Registers DIP-Switch Settings Dip-Switch Settings MT2834BA PC BoardDIP-Switch Option Settings Switch #4 AS/400 Mode Synchronous Mode/Leased Line/Dial-UP = Down Down Dip-Switch Settings Speaker Volume Control Recording Option Configurations Switch Function Position EffectDIP Switches #15-16 MT2834BL DIP Switches #13-14DIP Switches #15-16 MT2834BA Warranty, Service and Tech Support Multi-Tech Systems, Inc. Warranty & Repairs Policies Warranty, Service, and Technical SupportOnline Warranty Registration Repair Procedures for International DistributorsInternet Sites Replacement PartsTechnical Support Country TelephoneAppendixes Appendix a Upgrading Your Modem’s Firmware Upgrade OverviewAppendix a Upgrading Your Modem’s Firmware Download the Upgrade File Upgrade the Modem’s Firmware Modem Does Not Respond to Commands Appendix B TroubleshootingNone of the LEDs Light When the Modem Is On Appendix B TroubleshootingAppendix B Troubleshooting Modem Dials But Cannot Make a Connection File Transfer Is Slower Than It Should Be Modem Cannot Connect When AnsweringModem Disconnects While On-line Am Losing DataAm Getting Garbage Characters on the Monitor Command Values Description Appendix C AT Command SummaryAppendix C AT Command Summary DsNd Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 100$FCn MT2834BL Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 101$MBn Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 102$SBn Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 103Dial Tone Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 104Callback Security/Remote Configuration Command Summary Password Command Summary 25bis Commands25bis Operation Delayed and Forbidden NumbersAppendix D V.25bis Operation Appendix D V.25bis Operation25bis Set-Up and Initialization 25bis Mode AT Commands25bis DIP-Switches Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 108Change Serial Baud Rate CSP Command 25bis AT CommandsEnable/Disable V.25bis Mode $V Command 25bis Responses Result CodesListing Forbidden Phone Number RLF Command Dial Phone Number Provided CRN CommandListing Delayed Phone Numbers RLD Command Disregard or Connect to Incoming Calls DIC or CIC CommandITU V.25bis Country Specific Information Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 112 Appendix D V.25bis Operation BelgiumSingapore Appendix E MultiModemBA Cables Appendix E MultiModemBA/BL CablesFCC Part Appendix F Regulatory InformationFCC Part 68 Telecom Canadian Limitations Notice Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 115South African Notice Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 116Appendix G Weee Statement Index Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 11791-116 Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 118PBX/CBX Disconnect Drop Time for DSR/CTS/CD63 Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 119