·If you don’t get an OK, the problem may still be in the communications software. Make sure you have done whatever is necessary in your software to make a port connection. Not all communications programs connect to the COM port automatically. Some connect when the software loads and remain connected until the program terminates. Others can disconnect without exiting the program (make sure the Connect icon looks plugged in). If the terminal reports that it cannot make a connection, yet the modem’s TR indicator is on, click on the Window menu to see if more than one terminal is open. The modem’s TR indicator shows that the software has made a connection with the modem through the COM port.

·Your communications software settings may not match the physical port the modem is connected to. The serial cable may be plugged into the wrong connector—check your computer documentation to make sure. Or you may have selected a COM port in your software other than the one the modem is physically connected to—compare the settings in your software to the physical connection.

·If the modem is on, the cable is plugged into the correct port, the communications software is configured correctly, and you still don’t get an OK, the fault may be in the serial cable. Make sure it is firmly connected at both ends.

·Is this the first time you have used the cable? If so, it may not be correct. Check the cable description on the packaging to make sure the cable is the right one for your computer.

·Peripheral expansion cards, such as bus mouse and sound cards, may include a serial port pre- configured as COM1 or COM2. The extra serial port, or the card itself, may use the same COM port, memory address, or interrupt request (IRQ) as your communications port. Be sure to disable any unused ports.

To look for address or IRQ conflicts if you use Windows 3.1x, select File, Run in Program Manager, type MSD, and press ENTER. Then select Mouse, COM Ports, and IRQ Status and note the addresses and IRQs that are in use. If you find an IRQ conflict, note which IRQs are not being used, then change one of the conflicting devices to use one of the unused IRQs. If you find an address conflict, change the address of one of the conflicting devices.

To change a port address or IRQ in Windows 3.1x, double-click the Control Panel icon, then the Ports icon. Click on the port you want to change, click Settings, click Advanced, and select the new port address and/or interrupt. If you wish to use COM3 or COM4, note that COM3 shares an IRQ with COM1, as does COM4 with COM2, so you should change their IRQs to unused ones, if possible.

If you use Windows 95, right-click on My Computer, select Properties from the menu, click on the Device Manager tab, double-click on Ports, then double-click on the Communications Port your modem is connected to. In the port’s Properties sheet, click on the Resources tab to see the port’s Input/Output range and Interrupt Request. If another device is using the same address range or IRQ, it will appear in the Conflicting Device List. Uncheck Use Automatic Settings to change the port’s settings so they do not conflict with the other device, or select the port the conflicting device is on and change it instead. If you need to open your computer to change switches or jumpers on the conflicting device; refer to the device’s documentation.

·The serial port may be defective. If you have another serial port, install the modem on it, change the COM port setting in your software, and try again.

·The modem may be defective. If you have another Multi-Tech modem, try swapping modems. If the problem goes away, the first modem is possibly defective. Call Tech Support for assistance.

Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide

95

Image 95
Contents User Guide Trademarks User GuideRecord of Revisions Date Description PatentsContents Index 117 RegistersIntroduction and Description Introduction How To Use This ManualModem Features Fax Features 1 MT2834BA/BL Series FeaturesTechnical Specifications Power MT2834BA LED Display Modem LED IndicatorsControls on PC Board Installation and Connection Installation Procedure What Is in Your Modem Package?Installation Safety WarningsMultiModemBA Connections Is Your Modem Ready for Use? Installing PhoneTools, the Data Communications SoftwareSoftware Configuration and Modem Basics PC Initialization Strings Configuring Your SoftwareConfiguring Software for Your Modem Software ConfigurationAT &F S0=0 &F9 &W0 CR Changing Default ParametersConfiguring Software for Your Computer Other ParametersSimple Operations Answer/Originate Voice/Data Toggle SwitchModem Basics Manual Dial and Automatic Answer Manual Dial and Automatic Answer Dialing/On-Line/AnsweringAutomatic Leased Line Restoral Operation Manual Dial Backup Call TerminationDial Backup and Leased Line Restoral Manual Call Origination Dial-Up OperationManual Answering Automatic AnsweringCall Termination Abort TimerHandshaking Details Command Mode Functional Modes AT Command EditingCommand Mode Functional Modes Summary of AT CommandsStore Modem Configure Data Standard AT Result Codes Result CodesMulti-Tech Result Codes Dialing Action Commands Dialing CommandsSet Pulse Dial Ratios &P Dial Modifier CommandsVoice/Data Dialing $VD Pulse or Tone Dial P TLong Space Disconnect Y Return to Command Mode After Dial Command ExecutionReverse the Mode of Operation R Automatic Pauses in DialingQuiet Answer @ Calling Card Detect Tones $Listing Numbers Stored in Memory L Phone Number Memory CommandsStoring Phone Numbers D...N Number Linking NNModem Reset Z Configuration and Default Storage CommandsLoading Factory Defaults &F Synchronous Transmit Clock Select &X Async/Sync Mode Switching &MUnix Uucp Spoofing $SP Result Codes Multi-Tech or Standard AT &Q Command Response Result Code CommandsEcho Command Mode Characters E Result Codes Enable/Disable and No Response Answer QResult Codes Basic and Extended and Call Progress Selection Bell/V.21 Tone Phone Line Conditioning CommandsEnable/Disable Trelis Coded Modulation #T Guard Tones Not Used in BAI/BLI Models &GAuto Speed Detect #A Fallback Modes When On-Line #FEnable/Disable Lowspeed Fast Connect $FC Cleardown at Disconnect &CDCTS Control &R 7 RS-232C Interface Control CommandsCarrier Detect Control &C Data Terminal Ready Control &DDSR/CD Interaction Control &SF Data Set Ready Control &SCTS/RTS Interaction Control &RF Reliable Mode &E2 Error Correction CommandsNormal Mode &E0 Auto-Reliable Mode &E1Auto-Reliable Buffering $A Mode Select #LRetransmit Count $R Enable/Disable Auto Reliable Fallback Character $FError Correction/300bps $E Xon/Xoff Flow Control &E5 Flow Control CommandsHardware Flow Control &E4 Hewlett-Packard ENQ/ACK Pacing &E9 Xon/Xoff Pass-Through &E7Send Xon/Xoff Characters #X Parity Selection #P Normal Mode Modem Flow Control On &E11Terminal/Computer Initiated Pacing &E13 Maximum Block Size &BSEnq/Ack Pacing Commands Normal/Auto-Reliable/Reliable Mode CommandsXon/Xoff Pass-Through Commands Modem Baud Rate $MB Speed Conversion CommandsSpeed Conversion $BA Serial Port Baud Rate $SB Immediate Action Commands Off Hook H Listing On-Line Diagnostics L8Exiting Command Mode, Going Back On-Line O Line Probe CommandsForce Answer Mode a Registers Return Character Number of Rings Until Modem AnswersRings Which Have Occurred Escape Code CharacterWait Time for Dial Tone Time for Carrier Abort TimerLine Feed Character Backspace CharacterS11 Tone Dialing Tone Spacing and Duration S10 Carrier Loss Disconnect Delay TimeS13 Remote Configuration Escape Character Carrier Detect Response TimeS17 Changing Break Time S15 Callback Time DelayS19 MT2834BL Only Dial-Back Timer S16 Callback AttemptsS25 DTR Dropout Time S26 Failed Password AttemptsS29 Local Inactivity Timer S24 PBX/CBX Disconnect Drop Time for DSR/CTS/CDS37 Time Between DTR Active and Modem On-Hook S30 Inactivity TimerS32 Time Elapse for Escape Sequence S36 Time Between DTR Inactive and Modem Off-HookS48 Program V.34bis Connect Speeds Examples of Reading Values Reading and Assigning S-Register ValuesExamples of Assigning Values AT Command and S-Register Summary Callback Security and Remote Configuration Callback Security and Remote Configuration Callback Feature DescriptionTo change your Remote Configuration feature status Remote Configuration DescriptionAT#CBN0xxxxxxxxxxCR To set parity of the password/message promptCallback Operational Sequence Procedures Remote Configuration Operation Procedures Remote Configuration ProceduresRemote Configuration and Callback Security AT Commands Remote Configuration/Callback Security S-Registers DIP-Switch Settings MT2834BA PC Board Dip-Switch SettingsDIP-Switch Option Settings Switch #4 AS/400 Mode Synchronous Mode/Leased Line/Dial-UP = Down Down Dip-Switch Settings Speaker Volume Control Switch Function Position Effect Recording Option ConfigurationsDIP Switches #15-16 MT2834BL DIP Switches #13-14DIP Switches #15-16 MT2834BA Warranty, Service and Tech Support Warranty, Service, and Technical Support Multi-Tech Systems, Inc. Warranty & Repairs PoliciesRepair Procedures for International Distributors Online Warranty RegistrationCountry Telephone Replacement PartsTechnical Support Internet SitesAppendixes Appendix a Upgrading Your Modem’s Firmware Upgrade OverviewAppendix a Upgrading Your Modem’s Firmware Download the Upgrade File Upgrade the Modem’s Firmware Appendix B Troubleshooting Appendix B TroubleshootingNone of the LEDs Light When the Modem Is On Modem Does Not Respond to CommandsAppendix B Troubleshooting Modem Dials But Cannot Make a Connection Am Losing Data Modem Cannot Connect When AnsweringModem Disconnects While On-line File Transfer Is Slower Than It Should BeAm Getting Garbage Characters on the Monitor Command Values Description Appendix C AT Command SummaryAppendix C AT Command Summary Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 100 DsNdMulti-Tech Systems, Inc. MT2834BA/BL Series User Guide 101 $FCn MT2834BLMulti-Tech Systems, Inc. MT2834BA/BL Series User Guide 102 $MBnMulti-Tech Systems, Inc. MT2834BA/BL Series User Guide 103 $SBnMulti-Tech Systems, Inc. MT2834BA/BL Series User Guide 104 Dial ToneCallback Security/Remote Configuration Command Summary 25bis Commands Password Command SummaryAppendix D V.25bis Operation Delayed and Forbidden NumbersAppendix D V.25bis Operation 25bis OperationMulti-Tech Systems, Inc. MT2834BA/BL Series User Guide 108 25bis Mode AT Commands25bis DIP-Switches 25bis Set-Up and Initialization25bis Responses Result Codes 25bis AT CommandsEnable/Disable V.25bis Mode $V Command Change Serial Baud Rate CSP CommandDisregard or Connect to Incoming Calls DIC or CIC Command Dial Phone Number Provided CRN CommandListing Delayed Phone Numbers RLD Command Listing Forbidden Phone Number RLF CommandITU V.25bis Country Specific Information Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 112 Appendix D V.25bis Operation BelgiumSingapore Appendix E MultiModemBA/BL Cables Appendix E MultiModemBA CablesFCC Part Appendix F Regulatory InformationFCC Part 68 Telecom Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 115 Canadian Limitations NoticeMulti-Tech Systems, Inc. MT2834BA/BL Series User Guide 116 South African NoticeAppendix G Weee Statement Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 117 IndexMulti-Tech Systems, Inc. MT2834BA/BL Series User Guide 118 91-116Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 119 PBX/CBX Disconnect Drop Time for DSR/CTS/CD63