Multi-Tech Systems MT2834BL Series manual Automatic Pauses in Dialing, Long Space Disconnect Y

Page 35

Chapter 5 - Command Mode

Automatic Pauses in Dialing ,

You can cause the modem to pause during the dialing sequence by entering a comma character where the pause is desired. This pause lasts two seconds. If a longer pause is desired, more than one comma may be entered consecutively, with each comma causing a two second pause. You also have the option of changing the length of the pause caused by the comma, from two seconds to any other value from 0 up to 255 seconds. This is done by setting S-Register S8 (refer to Chapter 6). Each comma in a dialing command counts as one of the sixty allowed characters.

Long Space Disconnect Y

When two modems are connected in Normal mode (i.e. without error correction) there is no "polite" means of requesting a disconnect. A link disconnect request packet is sent under reliable connections. As a result some "garbage" may be received when a hang-up command is issued. The Y1 command enables the modem to use the break signal which accomplishes the hang-up as an instruction to shut off its receiver and disconnect (both modems must have Y1 enabled for this feature to be effective). Y0 (factory default) disables this function.

Wait for New Dial-Tone W

A W inserted in the dialing command causes the modem to wait for another dial tone, and not resume dialing until another dial tone is detected.

It is not necessary to enter a W at the beginning of the dialing command to wait for a modem dial tone, because the modem will do that first (pause automatically).

In order for this command to work, you must select Wait-For-Dial Tone dialing with the X2 or X4 command, so that your modem will be able to detect the dial tone.

Return to Command Mode After Dial Command Execution ;

A semicolon (;), entered as the last character of a dialing command causes the modem to return to the Command mode immediately after executing the command, instead of waiting for a carrier signal and going on line.

For example, entering ATDT5551212; would tone-dial the number, and do nothing afterwards except go back into Command mode. This can be useful in dialing applications where modem data transfer is not desired, such as voice communications, or in applications involving the use of touch tones as a data entry method, such as bank-by-phone.

Reverse the Mode of Operation R

In certain operations you may need to reverse the mode of operation for your modem from originate to answer or answer to originate so that it would answer the phone and go into answer mode. This command turns off the reversing function with the R0 command and turns it on with the R1 command with the modem in either command mode. If you want to reverse from the originate mode, use R (with no number) in the dialing string.

Flash On Hook !

Some switchboard systems react to a momentary On Hook. An exclamation mark inserted in the command causes the modem to “flash” on hook for a half of a second, as if you had held the switch hook button on a telephone down for a half second.

For example, to flash On Hook after dialing the number 555-1234 in order to transfer to Extension #5678, you might enter ATDT5551234,,!5678. The commas cause a 4 second pause (just to be safe).

Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide

35

Image 35
Contents User Guide Trademarks User GuideRecord of Revisions Date Description PatentsContents Index 117 RegistersIntroduction and Description Introduction How To Use This ManualModem Features Fax Features 1 MT2834BA/BL Series FeaturesTechnical Specifications Power MT2834BA LED Display Modem LED IndicatorsControls on PC Board Installation and Connection Installation Procedure What Is in Your Modem Package?Installation Safety WarningsMultiModemBA Connections Is Your Modem Ready for Use? Installing PhoneTools, the Data Communications SoftwareSoftware Configuration and Modem Basics PC Initialization Strings Configuring Your SoftwareConfiguring Software for Your Modem Software ConfigurationAT &F S0=0 &F9 &W0 CR Changing Default ParametersConfiguring Software for Your Computer Other ParametersSimple Operations Answer/Originate Voice/Data Toggle SwitchModem Basics Manual Dial and Automatic Answer Manual Dial and Automatic Answer Dialing/On-Line/AnsweringAutomatic Leased Line Restoral Operation Manual Dial Backup Call TerminationDial Backup and Leased Line Restoral Manual Call Origination Dial-Up OperationManual Answering Automatic AnsweringCall Termination Abort TimerHandshaking Details Command Mode Functional Modes AT Command EditingCommand Mode Functional Modes Summary of AT CommandsStore Modem Configure Data Standard AT Result Codes Result CodesMulti-Tech Result Codes Dialing Action Commands Dialing CommandsSet Pulse Dial Ratios &P Dial Modifier CommandsVoice/Data Dialing $VD Pulse or Tone Dial P TLong Space Disconnect Y Return to Command Mode After Dial Command ExecutionReverse the Mode of Operation R Automatic Pauses in DialingQuiet Answer @ Calling Card Detect Tones $Listing Numbers Stored in Memory L Phone Number Memory CommandsStoring Phone Numbers D...N Number Linking NNModem Reset Z Configuration and Default Storage CommandsLoading Factory Defaults &F Synchronous Transmit Clock Select &X Async/Sync Mode Switching &MUnix Uucp Spoofing $SP Result Codes Multi-Tech or Standard AT &Q Command Response Result Code CommandsEcho Command Mode Characters E Result Codes Enable/Disable and No Response Answer QResult Codes Basic and Extended and Call Progress Selection Bell/V.21 Tone Phone Line Conditioning CommandsEnable/Disable Trelis Coded Modulation #T Guard Tones Not Used in BAI/BLI Models &GAuto Speed Detect #A Fallback Modes When On-Line #FEnable/Disable Lowspeed Fast Connect $FC Cleardown at Disconnect &CDCTS Control &R 7 RS-232C Interface Control CommandsCarrier Detect Control &C Data Terminal Ready Control &DDSR/CD Interaction Control &SF Data Set Ready Control &SCTS/RTS Interaction Control &RF Reliable Mode &E2 Error Correction CommandsNormal Mode &E0 Auto-Reliable Mode &E1Auto-Reliable Buffering $A Mode Select #LRetransmit Count $R Enable/Disable Auto Reliable Fallback Character $FError Correction/300bps $E Xon/Xoff Flow Control &E5 Flow Control CommandsHardware Flow Control &E4 Hewlett-Packard ENQ/ACK Pacing &E9 Xon/Xoff Pass-Through &E7Send Xon/Xoff Characters #X Parity Selection #P Normal Mode Modem Flow Control On &E11Terminal/Computer Initiated Pacing &E13 Maximum Block Size &BSEnq/Ack Pacing Commands Normal/Auto-Reliable/Reliable Mode CommandsXon/Xoff Pass-Through Commands Modem Baud Rate $MB Speed Conversion CommandsSpeed Conversion $BA Serial Port Baud Rate $SB Immediate Action Commands Off Hook H Listing On-Line Diagnostics L8Exiting Command Mode, Going Back On-Line O Line Probe CommandsForce Answer Mode a Registers Return Character Number of Rings Until Modem AnswersRings Which Have Occurred Escape Code CharacterWait Time for Dial Tone Time for Carrier Abort TimerLine Feed Character Backspace CharacterS11 Tone Dialing Tone Spacing and Duration S10 Carrier Loss Disconnect Delay TimeS13 Remote Configuration Escape Character Carrier Detect Response TimeS17 Changing Break Time S15 Callback Time DelayS19 MT2834BL Only Dial-Back Timer S16 Callback AttemptsS25 DTR Dropout Time S26 Failed Password AttemptsS29 Local Inactivity Timer S24 PBX/CBX Disconnect Drop Time for DSR/CTS/CDS37 Time Between DTR Active and Modem On-Hook S30 Inactivity TimerS32 Time Elapse for Escape Sequence S36 Time Between DTR Inactive and Modem Off-HookS48 Program V.34bis Connect Speeds Examples of Reading Values Reading and Assigning S-Register ValuesExamples of Assigning Values AT Command and S-Register Summary Callback Security and Remote Configuration Callback Security and Remote Configuration Callback Feature DescriptionTo change your Remote Configuration feature status Remote Configuration DescriptionAT#CBN0xxxxxxxxxxCR To set parity of the password/message promptCallback Operational Sequence Procedures Remote Configuration Operation Procedures Remote Configuration ProceduresRemote Configuration and Callback Security AT Commands Remote Configuration/Callback Security S-Registers DIP-Switch Settings MT2834BA PC Board Dip-Switch SettingsDIP-Switch Option Settings Switch #4 AS/400 Mode Synchronous Mode/Leased Line/Dial-UP = Down Down Dip-Switch Settings Speaker Volume Control Switch Function Position Effect Recording Option ConfigurationsDIP Switches #15-16 MT2834BL DIP Switches #13-14DIP Switches #15-16 MT2834BA Warranty, Service and Tech Support Warranty, Service, and Technical Support Multi-Tech Systems, Inc. Warranty & Repairs PoliciesRepair Procedures for International Distributors Online Warranty RegistrationCountry Telephone Replacement PartsTechnical Support Internet SitesAppendixes Appendix a Upgrading Your Modem’s Firmware Upgrade OverviewAppendix a Upgrading Your Modem’s Firmware Download the Upgrade File Upgrade the Modem’s Firmware Appendix B Troubleshooting Appendix B TroubleshootingNone of the LEDs Light When the Modem Is On Modem Does Not Respond to CommandsAppendix B Troubleshooting Modem Dials But Cannot Make a Connection Am Losing Data Modem Cannot Connect When AnsweringModem Disconnects While On-line File Transfer Is Slower Than It Should BeAm Getting Garbage Characters on the Monitor Command Values Description Appendix C AT Command SummaryAppendix C AT Command Summary Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 100 DsNdMulti-Tech Systems, Inc. MT2834BA/BL Series User Guide 101 $FCn MT2834BLMulti-Tech Systems, Inc. MT2834BA/BL Series User Guide 102 $MBnMulti-Tech Systems, Inc. MT2834BA/BL Series User Guide 103 $SBnMulti-Tech Systems, Inc. MT2834BA/BL Series User Guide 104 Dial ToneCallback Security/Remote Configuration Command Summary 25bis Commands Password Command SummaryAppendix D V.25bis Operation Delayed and Forbidden NumbersAppendix D V.25bis Operation 25bis OperationMulti-Tech Systems, Inc. MT2834BA/BL Series User Guide 108 25bis Mode AT Commands25bis DIP-Switches 25bis Set-Up and Initialization25bis Responses Result Codes 25bis AT CommandsEnable/Disable V.25bis Mode $V Command Change Serial Baud Rate CSP CommandDisregard or Connect to Incoming Calls DIC or CIC Command Dial Phone Number Provided CRN CommandListing Delayed Phone Numbers RLD Command Listing Forbidden Phone Number RLF CommandITU V.25bis Country Specific Information Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 112 Appendix D V.25bis Operation BelgiumSingapore Appendix E MultiModemBA/BL Cables Appendix E MultiModemBA CablesFCC Part Appendix F Regulatory InformationFCC Part 68 Telecom Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 115 Canadian Limitations NoticeMulti-Tech Systems, Inc. MT2834BA/BL Series User Guide 116 South African NoticeAppendix G Weee Statement Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 117 IndexMulti-Tech Systems, Inc. MT2834BA/BL Series User Guide 118 91-116Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 119 PBX/CBX Disconnect Drop Time for DSR/CTS/CD63