Multi-Tech Systems MT2834BA Series manual Dial Modifier Commands, Voice/Data Dialing $VD

Page 34

Chapter 5 - Command Mode

To activate DTR Dialing, enter AT$D1 and hit RETURN. The modem dials the phone number stored in the N0 location of memory when it receives a high DTR signal. DTR must remain high for the duration of the call, until disconnect. To deactivate DTR dialing, enter AT$D0 and hit RETURN.

Note when using DTR Dialing in a synchronous application, be sure DIP-Switch #8 is in the UP position to disable V.25bis Command mode.

Voice/Data Dialing $VD

Another alternate method of causing the modem to automatically dial is Voice/Data Dialing. With Voice/Data Dialing, the modem automatically dials the phone number stored in the N1 position of memory whenever the Voice/Data switch is toggled. You must first enter AT$VD1&W0<CR>. This command string enables Voice/Data dialing when the Voice/Data toggle switch is activated. To disable Voice/Data Dialing (default), enter the command AT$VD0 W0<CR>.

5.4.2Dial Modifier Commands

There are several command characters that can be included within a dialing command (following the letter D), called “Dial Modifiers”. They have various functions, including the selection of Pulse or Tone Dialing, pauses in the dial sequence, automatic re-dials if a number is busy, and reverting to the Command mode or switching to the Answer mode after dialing.

Pulse or Tone Dial P T

The modem dials numbers using either pulse or tone dialing, or a combination of both methods. Pulse dialing is a method used by rotary-dial telephones, which involves the timed opening and closing of line relay.

Tone dialing is the method used by push-button (touch tone) telephones, and is sometimes referred to as DTMF, or Dual-Tone Multi-Frequency dialing.

The method used is selected by including a P for Pulse or a T for Tone in the dialing command, right before the digits you wish to have dialed in that manner.

For example, you would pulse-dial the number 555-1212 by entering ATDP5551212 and hitting RETURN. You could tone-dial the same number by entering ATDT5551212 and hitting RETURN. If neither Pulse nor Tone dialing is specified in the dial command, the modem uses whatever method used last. If the modem has been reset or just powered up, it uses Pulse dialing, even if the letter P is not included in your dial command.

Nearly all telephone systems in the U.S. are now compatible with tone dialing. Since that is the faster method, you will probably choose the tone method for your dialing.

An example of combining pulse and tone dialing could involve a PBX system where 9 had to be pulse-dialed first, then the rest of the number tone-dialed after pausing for a second dial tone. The number would be dialed by entering ATDP9, T5551212 and RETURN. (The comma causes a pause, which we’ll explain soon.)

Set Pulse Dial Ratios &P

This command sets the time ratios between the open and closed portions of the dialing pulse frequencies. To set the dialing pulse ratio of 60 mSec to 40 mSec, enter AT&P0. To set a ratio of 67 mSec to 33 mSec, enter AT&P1. The factory default is &P0.

Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide

34

Image 34
Contents User Guide Patents User GuideRecord of Revisions Date Description TrademarksContents Registers Index 117Introduction and Description How To Use This Manual IntroductionModem Features 1 MT2834BA/BL Series Features Fax FeaturesTechnical Specifications Power Modem LED Indicators MT2834BA LED DisplayControls on PC Board Installation and Connection Safety Warnings What Is in Your Modem Package?Installation Installation ProcedureMultiModemBA Connections Installing PhoneTools, the Data Communications Software Is Your Modem Ready for Use?Software Configuration and Modem Basics Software Configuration Configuring Your SoftwareConfiguring Software for Your Modem PC Initialization StringsOther Parameters Changing Default ParametersConfiguring Software for Your Computer AT &F S0=0 &F9 &W0 CRModem Basics Answer/Originate Voice/Data Toggle SwitchSimple Operations Manual Dial and Automatic Answer Dialing/On-Line/Answering Manual Dial and Automatic AnswerDial Backup and Leased Line Restoral Manual Dial Backup Call TerminationAutomatic Leased Line Restoral Operation Dial-Up Operation Manual Call OriginationAutomatic Answering Manual AnsweringHandshaking Details Abort TimerCall Termination Command Mode Command Mode AT Command EditingFunctional Modes Summary of AT Commands Functional ModesStore Modem Configure Data Multi-Tech Result Codes Result CodesStandard AT Result Codes Dialing Commands Dialing Action CommandsPulse or Tone Dial P T Dial Modifier CommandsVoice/Data Dialing $VD Set Pulse Dial Ratios &PAutomatic Pauses in Dialing Return to Command Mode After Dial Command ExecutionReverse the Mode of Operation R Long Space Disconnect YCalling Card Detect Tones $ Quiet Answer @Number Linking NN Phone Number Memory CommandsStoring Phone Numbers D...N Listing Numbers Stored in Memory LLoading Factory Defaults &F Configuration and Default Storage CommandsModem Reset Z Unix Uucp Spoofing $SP Async/Sync Mode Switching &MSynchronous Transmit Clock Select &X Result Codes Enable/Disable and No Response Answer Q Command Response Result Code CommandsEcho Command Mode Characters E Result Codes Multi-Tech or Standard AT &QResult Codes Basic and Extended and Call Progress Selection Guard Tones Not Used in BAI/BLI Models &G Phone Line Conditioning CommandsEnable/Disable Trelis Coded Modulation #T Bell/V.21 ToneCleardown at Disconnect &CD Fallback Modes When On-Line #FEnable/Disable Lowspeed Fast Connect $FC Auto Speed Detect #AData Terminal Ready Control &D 7 RS-232C Interface Control CommandsCarrier Detect Control &C CTS Control &RCTS/RTS Interaction Control &RF Data Set Ready Control &SDSR/CD Interaction Control &SF Auto-Reliable Mode &E1 Error Correction CommandsNormal Mode &E0 Reliable Mode &E2Mode Select #L Auto-Reliable Buffering $AError Correction/300bps $E Enable/Disable Auto Reliable Fallback Character $FRetransmit Count $R Hardware Flow Control &E4 Flow Control CommandsXon/Xoff Flow Control &E5 Send Xon/Xoff Characters #X Xon/Xoff Pass-Through &E7Hewlett-Packard ENQ/ACK Pacing &E9 Maximum Block Size &BS Normal Mode Modem Flow Control On &E11Terminal/Computer Initiated Pacing &E13 Parity Selection #PXon/Xoff Pass-Through Commands Normal/Auto-Reliable/Reliable Mode CommandsEnq/Ack Pacing Commands Speed Conversion $BA Speed Conversion CommandsModem Baud Rate $MB Serial Port Baud Rate $SB Immediate Action Commands Listing On-Line Diagnostics L8 Off Hook HForce Answer Mode a Line Probe CommandsExiting Command Mode, Going Back On-Line O Registers Escape Code Character Number of Rings Until Modem AnswersRings Which Have Occurred Return CharacterBackspace Character Time for Carrier Abort TimerLine Feed Character Wait Time for Dial ToneCarrier Detect Response Time S10 Carrier Loss Disconnect Delay TimeS13 Remote Configuration Escape Character S11 Tone Dialing Tone Spacing and DurationS16 Callback Attempts S15 Callback Time DelayS19 MT2834BL Only Dial-Back Timer S17 Changing Break TimeS24 PBX/CBX Disconnect Drop Time for DSR/CTS/CD S26 Failed Password AttemptsS29 Local Inactivity Timer S25 DTR Dropout TimeS36 Time Between DTR Inactive and Modem Off-Hook S30 Inactivity TimerS32 Time Elapse for Escape Sequence S37 Time Between DTR Active and Modem On-HookS48 Program V.34bis Connect Speeds Examples of Assigning Values Reading and Assigning S-Register ValuesExamples of Reading Values AT Command and S-Register Summary Callback Security and Remote Configuration Callback Feature Description Callback Security and Remote ConfigurationRemote Configuration Description To change your Remote Configuration feature statusTo set parity of the password/message prompt AT#CBN0xxxxxxxxxxCRCallback Operational Sequence Procedures Remote Configuration Procedures Remote Configuration Operation ProceduresRemote Configuration and Callback Security AT Commands Remote Configuration/Callback Security S-Registers DIP-Switch Settings Dip-Switch Settings MT2834BA PC BoardDIP-Switch Option Settings Switch #4 AS/400 Mode Synchronous Mode/Leased Line/Dial-UP = Down Down Dip-Switch Settings Speaker Volume Control Recording Option Configurations Switch Function Position EffectDIP Switches #15-16 MT2834BA DIP Switches #13-14DIP Switches #15-16 MT2834BL Warranty, Service and Tech Support Multi-Tech Systems, Inc. Warranty & Repairs Policies Warranty, Service, and Technical SupportOnline Warranty Registration Repair Procedures for International DistributorsInternet Sites Replacement PartsTechnical Support Country TelephoneAppendixes Appendix a Upgrading Your Modem’s Firmware Upgrade OverviewAppendix a Upgrading Your Modem’s Firmware Download the Upgrade File Upgrade the Modem’s Firmware Modem Does Not Respond to Commands Appendix B TroubleshootingNone of the LEDs Light When the Modem Is On Appendix B TroubleshootingAppendix B Troubleshooting Modem Dials But Cannot Make a Connection File Transfer Is Slower Than It Should Be Modem Cannot Connect When AnsweringModem Disconnects While On-line Am Losing DataAm Getting Garbage Characters on the Monitor Appendix C AT Command Summary Appendix C AT Command SummaryCommand Values Description DsNd Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 100$FCn MT2834BL Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 101$MBn Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 102$SBn Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 103Dial Tone Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 104Callback Security/Remote Configuration Command Summary Password Command Summary 25bis Commands25bis Operation Delayed and Forbidden NumbersAppendix D V.25bis Operation Appendix D V.25bis Operation25bis Set-Up and Initialization 25bis Mode AT Commands25bis DIP-Switches Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 108Change Serial Baud Rate CSP Command 25bis AT CommandsEnable/Disable V.25bis Mode $V Command 25bis Responses Result CodesListing Forbidden Phone Number RLF Command Dial Phone Number Provided CRN CommandListing Delayed Phone Numbers RLD Command Disregard or Connect to Incoming Calls DIC or CIC CommandITU V.25bis Country Specific Information Singapore Appendix D V.25bis Operation BelgiumMulti-Tech Systems, Inc. MT2834BA/BL Series User Guide 112 Appendix E MultiModemBA Cables Appendix E MultiModemBA/BL CablesFCC Part 68 Telecom Appendix F Regulatory InformationFCC Part Canadian Limitations Notice Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 115South African Notice Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 116Appendix G Weee Statement Index Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 11791-116 Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 118PBX/CBX Disconnect Drop Time for DSR/CTS/CD63 Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide 119