MultiVOIP Quick Start Guide
specific type of FXO Disconnect: current loss, tone detection, or silence detection. Check with your in- house phone personnel to verify the preferred type of disconnect to use. For tone detection, you can select from the lists either one or two tones that will cause the line to disconnect. The person hanging up a call must then hit the key or keys that will produce those tones. For silence detection, select One Way or Two Way, then set the timer for the number of seconds of silence before disconnect. The default value of 15 seconds may be shorter than desired for your application.
To dedicate a local voice/fax channel to a remote voice/fax channel, (so you will not have to dial the remote channel) select the Auto Call Enable check box. Enter the phone number of the remote VOIP in the Phone Number box.
The FXS Options control how the selected channel interacts with answering machines. If the Current Loss check box is selected, the local VOIP hangs up when the electrical current is lost. The remote VOIPs must also be configured for current loss. The Ring Count box contains the number of rings before the caller hears a fast Busy signal. If this happens, hang up and try again. The default setting is 8 rings.
Note: After configuring a given channel, you can copy that channel’s configuration to any other channel by clicking Copy. Everything on the Interface tab will be copied to the other channel.
15.Repeat the above steps to configure the interface type for each voice/fax channel.
The Voice/Fax tab displays the parameters for the voice coder, faxing, and DTMF gain.
20