Multi-Tech Systems MT3334HD8 Reading and Assigning S-Register Values, Examples of Reading Values

Page 57

4 S-Registers

Reading and Assigning S-Register Values

Use the S command to assign a value to an S-register and to read an S-register’s current value.

To read an S-register value, in terminal mode, type S, the S-register number, and a question mark (?), and press ENTER. For example, to display the value of register S7, type ATS7? and press ENTER. The answer will appear as a three-digit decimal number (e.g., 045).

To assign a new value to an S-register, type S, the S-register number, an equals sign (=), and a decimal number. Convert all ASCII characters to their decimal equivalents before entering them. S-register decimal values are 0–127 for ASCII characters, and 0–255 for numeric values. To make the change permanent, use the &W0 command.

Examples of Assigning Values

1.Let’s assume you want to have longer pauses caused by the comma in a dial command: five seconds instead of two. Type ATS8=5 to assign 5 as the value for register S8. The modem will now pause five seconds for every comma in a dial command.

2.Or let’s assume that you wish to configure the modem to answer incoming calls after the thirtieth ring instead of after the first ring. To configure register S0 with a value of 30, type ATS0=30 and press ENTER.

3.Or let’s say you are calling long distance to another country code, and it is taking a long time to connect. The register S7 (abort timer) factory default setting of 45 seconds is insufficient; the abort timer times out and cancels the call before a connection is made. To change the S7 value to 55 seconds, type ATS7=55 and press ENTER. Now, after dialing, the modem allows 10 more seconds for a carrier signal before aborting the call. The additional 10 seconds should provide enough time for international calls.

Examples of Reading Values

1.To verify that you entered the value correctly in the preceding examples, type ATS8? and press ENTER in the first example, ATS0? in the second example, and ATS2? in the third example. You should receive the responses 005, 030, and 055, respectively.

2.When configuring S-registers, it is a good practice to include the verification read command in the same command string as the configuration assignment command. In the three preceding examples, type ATS8=5S8?, ATS0=30S3?, and ATS7=55S7?, respectively.

AT Commands that Affect S-Registers

For maximum throughput, the MT3334HD8’s default configuration is for originating a call to another 33,600 bps modem that supports error correction, data compression, and flow control. If the receiving modem is not compatible, the MT3334HD8 can match any ITU-T or Bell standard modem (but not proprietary protocols).

If you require a different configuration for your application, for example, if you want to use an MT3334HD8 modem strictly as an auto answering device, or for service that does not support error correction, you can selectively change the command parameters and S-register values in active memory and save the new values by using the &W command.

CommPlete Communications Server

51

Image 57
Contents MT3334HD8 Modem User Guide Multi-Tech Systems, Inc Woodale Drive Mounds View, Minnesota CommPlete Communications Server Canadian Limitations Notice FCC Fax WarningTable of Contents Warranty, Service, and Technical Support Testing the MT3334HD8Appendix D Appendix FIntroduction Power Supplies LED IndicatorsIntroduction Manual OrganizationInstallation Data Rates Modem Technical SpecificationsIntroduction 2400 & 1200 bps MT3334HD8 User Guide Power Installation MT3334HD8 modem card Safety WarningsInstallation Procedure Pre-Installation NotesPage AT Commands Working with AT Commands Command StructureModes of Operation Command Editing AT Commands by Function $BA Dial Modifier Commands Dialing CommandsDs Dial Continuous RedialWait for New Dial Tone Pulse or Tone DialingReturn to Command Mode After Dialing Rn Reverse Originate/Answer ModeDialing Pause Flash On-Hook@ Quiet Answer Phone Number Memory CommandsCall Card Tone Detect DsNd Store a Phone NumberWn Store Configuration Configuration Storage and Recall CommandsNdNe Number Linking List Stored Telephone NumbersModem Response Result Code Commands Fn Load Default ConfigurationReset Modem Echo Command Mode Characters Result Codes Verbose/Terse An Answerback Online Connection Commands#An Auto Speed Detection Bn Answer ToneDCn AT Command Control CDn Cleardown at DisconnectDTn Dtmf Detection Gn Guard Tones #Fn Fallback ModesHn Busy-Out After Disconnect Pn Set Pulse-Dial RatiosRDn Square Wave Ring Detect $Tn Calling Tone#Tn Trellis-Coded Modulation Fn Echo Canceler Frequency Offset Compensation CommandsYn Long Space Disconnect RAn Asymmetric Bit RateRS-232 Interface Commands Cn Carrier Detect ControlDn Data Terminal Ready Control Sn Data Set Ready Control Rn Clear to Send ControlRFn CTS/RTS Interaction Control SFn DSR/CD Interaction ControlEn Error Correction Modes Error Correction and Data Compression Commands#Ln V.42 Error Correction Modes En Data Compression$En V.42 Error Correction at 300 bps $Fn Auto-Reliable Fallback Character Enable/Disable$An Auto-Reliable Buffering Speed Conversion Commands $BAn Baud Adjust$Rn Retransmit Count $SBn Serial Port Baud Rate $MBn Modem Baud RateRepeat Last Command Immediate Action CommandsInquire Product Code L5, L7 List Current Operating ParametersFlow Control Commands En Non-Error Correction Mode Flow Control E3 Flow Control DisableE4 Hardware Flow Control E5 XON/XOFF Flow Control#Xn Number of Xoff Characters Sent En Pacing Computer-Initiated Flow ControlEscape Sequences Force Answer Mode+++ATCR In-Band Escape Sequence Breakatcr Out-of-Band Escape SequenceAtcr Remote Configuration Escape Sequence Remote Configuration Commands#Ixxxxxx Change Login Password Go Back Online#Syyyyyy Change Setup Password Line Probe CommandsDPn Read Line Probe Data DFn Format Line Probe DataTn Respond to Remote Digital Loopback Signal Diagnostic CommandsRP Immediate Line Probe Ln Display Line Probe DataUn Loopback Test Modes MT3334HD8 User Guide Registers S0 Number of Rings Until Modem Answers RegistersS1 Ring Count S2 Escape Code CharacterS4 Line Feed Character S7 Time for Carrier Abort TimerS5 Backspace Character S6 Wait Time for Dial ToneS13 Remote Configuration Escape Character S10 Carrier Loss Disconnect Delay TimeS9 Carrier Detect Response Time S11 Tone Dialing Spacing and DurationS34 Command Buffer Length After Online Escape Sequence S30 Inactivity TimerS24 PBX/CBX Disconnect Drop Time for DSR/CTS/CD S25 DTR Dropout TimeS37 DTR Busy-In Time S94 Out-of-Service TimeS43 Force V.34 Connect Speed S48 Maximum V.34 Connect SpeedReading and Assigning S-Register Values AT Commands that Affect S-RegistersExamples of Assigning Values Examples of Reading ValuesAT&E2$SP1#L3$R0$MB19200$SB115200$EB1S0=10&W0CR Testing the MT3334HD8 Local Analog Loopback Test V.54 Loop Test procedureRemote Digital Loopback Test V.54 Loop Testing the MT3334HD8Dial the remote modem and establish your online connection Local digital loopback test Local Digital Loopback Test V.54 LoopPage Warranty, Service, and Technical Support Service Limited WarrantyRecording Product Information Technical SupportMulti-Tech BBS Logging onto the Multi-Tech BBSDownloading a File Reading a Message About CompuServeLeaving a Message BulletinsAbout the Internet About the Multi-Tech Fax-Back ServiceUpgrading the MT3334HD8 Firmware Using FlashPro to Upgrade FirmwareMT3334HD8 User Guide Appendixes Ctrl Code HEX DEC Appendix a Ascii Conversion ChartAppendix B Dial Pulses and Tones Dial PulsesTone Dial Frequencies Figure B-2. Standard Dtmf frequencies Multi-Tech Result Codes &Q0 Appendix C Result Code SummaryStandard AT Result Codes &Q1 Appendix D S-Register Summary Register Unit Range Default DescriptionSets fixed V.34 connect speed = 28800 bps Return Appendix E AT Command SummaryCDn AT Command Summary $Fn Command Values Description Command Values Description $MBn RAn Command Values Description SFn Command Values Description #Vn Breakatcr Appendix F Remote Configuration Basic ProcedureSetup Changing the Remote Escape Character Changing the PasswordsIndex MT3334HD8 User Guide Index Long space break Pacing, 36, 37, 38 enable/disable, 38 ENQ/ACK Commands Loopback tests, 42, 43, 54, 56 tone detection