C Result Code Summary

Appendix C Result Code Summary

Multi-Tech Result Codes (&Q0)

Terse

Verbose

Definition

0

OK

Command was executed without error; ready for next

 

 

command.

1

CONNECT

Modem has detected carrier and gone online.

2

RING

Modem has detected ring caused by incoming call.

3

NO CARRIER

No carrier signal has been detected within the allowed time.

4

ERROR

Error in command line (too many, or invalid characters).

5CONNECT 1200 Modem has detected carrier at 1200 bps and gone online.

6NO DIALTONE No dial tone has been detected.

7

BUSY

A busy signal has been detected.

8

NO ANSWER

The remote system did not answer.

9CONNECT 2400 Modem has detected carrier at 2400 bps and gone online.

10

Not used.

11CONNECT 4800 Modem has detected carrier at 4800 bps and gone online.

12CONNECT 9600 Modem has detected carrier at 9600 bps and gone online.

13CONNECT 14400 Modem has detected carrier at 14400 bps and gone online.

19CONNECT 19200 Modem has detected carrier at 19200 bps and gone online.

21CONNECT 21600 Modem has detected carrier at 21600 bps and gone online.

23CONNECT 1275 Modem is connected in V.23 mode.

24CONNECT 24000 Modem has detected carrier at 24000 bps and gone online.

26CONNECT 26400 Modem has detected carrier at 26400 bps and gone online.

28CONNECT 28800 Modem has detected carrier at 28800 bps and gone online.

31CONNECT 31200 Modem has detected carrier at 31200 bps and gone online.

33CONNECT 33600 Modem has detected carrier at 33600 bps and gone online.

MNP Reliable Mode. If the modem connects using MNP error correction, the word RELIABLE or the letter R is added to the CONNECT responses as follows:

1R

CONNECT RELIABLE

5R

CONNECT 1200

RELIABLE

9R

CONNECT 2400

RELIABLE

11R

CONNECT 4800

RELIABLE

12R

CONNECT 9600

RELIABLE

13R

CONNECT 14400 RELIABLE

19R

CONNECT 19200 RELIABLE

21R

CONNECT 21600 RELIABLE

24R

CONNECT 24000 RELIABLE

26R

CONNECT 26400

RELIABLE

28R

CONNECT 28800

RELIABLE

31R

CONNECT 31200

RELIABLE

33R

CONNECT 33600

RELIABLE

CommPlete Communications Server

71

Image 77
Contents MT3334HD8 Modem User Guide Multi-Tech Systems, Inc Woodale Drive Mounds View, Minnesota CommPlete Communications Server Canadian Limitations Notice FCC Fax WarningTable of Contents Warranty, Service, and Technical Support Testing the MT3334HD8Appendix D Appendix FIntroduction Power Supplies LED IndicatorsIntroduction Manual OrganizationInstallation Data Rates Modem Technical SpecificationsIntroduction 2400 & 1200 bps MT3334HD8 User Guide Power Installation MT3334HD8 modem card Safety WarningsInstallation Procedure Pre-Installation NotesPage AT Commands Modes of Operation Working with AT CommandsCommand Structure Command Editing AT Commands by Function $BA Dial Modifier Commands Dialing CommandsDs Dial Continuous RedialWait for New Dial Tone Pulse or Tone DialingReturn to Command Mode After Dialing Rn Reverse Originate/Answer ModeDialing Pause Flash On-Hook@ Quiet Answer Phone Number Memory CommandsCall Card Tone Detect DsNd Store a Phone NumberWn Store Configuration Configuration Storage and Recall CommandsNdNe Number Linking List Stored Telephone NumbersReset Modem Modem Response Result Code CommandsFn Load Default Configuration Echo Command Mode Characters Result Codes Verbose/Terse An Answerback Online Connection Commands#An Auto Speed Detection Bn Answer ToneDTn Dtmf Detection DCn AT Command ControlCDn Cleardown at Disconnect Gn Guard Tones #Fn Fallback ModesHn Busy-Out After Disconnect Pn Set Pulse-Dial Ratios#Tn Trellis-Coded Modulation RDn Square Wave Ring Detect$Tn Calling Tone Fn Echo Canceler Frequency Offset Compensation CommandsYn Long Space Disconnect RAn Asymmetric Bit RateDn Data Terminal Ready Control RS-232 Interface CommandsCn Carrier Detect Control Sn Data Set Ready Control Rn Clear to Send ControlRFn CTS/RTS Interaction Control SFn DSR/CD Interaction ControlEn Error Correction Modes Error Correction and Data Compression Commands#Ln V.42 Error Correction Modes En Data Compression$An Auto-Reliable Buffering $En V.42 Error Correction at 300 bps$Fn Auto-Reliable Fallback Character Enable/Disable $Rn Retransmit Count Speed Conversion Commands$BAn Baud Adjust $SBn Serial Port Baud Rate $MBn Modem Baud RateRepeat Last Command Immediate Action CommandsInquire Product Code L5, L7 List Current Operating ParametersFlow Control Commands En Non-Error Correction Mode Flow Control E3 Flow Control DisableE4 Hardware Flow Control E5 XON/XOFF Flow Control#Xn Number of Xoff Characters Sent En Pacing Computer-Initiated Flow ControlEscape Sequences Force Answer Mode+++ATCR In-Band Escape Sequence Breakatcr Out-of-Band Escape SequenceAtcr Remote Configuration Escape Sequence Remote Configuration Commands#Ixxxxxx Change Login Password Go Back Online#Syyyyyy Change Setup Password Line Probe CommandsDPn Read Line Probe Data DFn Format Line Probe DataTn Respond to Remote Digital Loopback Signal Diagnostic CommandsRP Immediate Line Probe Ln Display Line Probe DataUn Loopback Test Modes MT3334HD8 User Guide Registers S0 Number of Rings Until Modem Answers RegistersS1 Ring Count S2 Escape Code CharacterS4 Line Feed Character S7 Time for Carrier Abort TimerS5 Backspace Character S6 Wait Time for Dial ToneS13 Remote Configuration Escape Character S10 Carrier Loss Disconnect Delay TimeS9 Carrier Detect Response Time S11 Tone Dialing Spacing and DurationS34 Command Buffer Length After Online Escape Sequence S30 Inactivity TimerS24 PBX/CBX Disconnect Drop Time for DSR/CTS/CD S25 DTR Dropout TimeS37 DTR Busy-In Time S94 Out-of-Service TimeS43 Force V.34 Connect Speed S48 Maximum V.34 Connect SpeedReading and Assigning S-Register Values AT Commands that Affect S-RegistersExamples of Assigning Values Examples of Reading ValuesAT&E2$SP1#L3$R0$MB19200$SB115200$EB1S0=10&W0CR Testing the MT3334HD8 Local Analog Loopback Test V.54 Loop Test procedureRemote Digital Loopback Test V.54 Loop Testing the MT3334HD8Dial the remote modem and establish your online connection Local digital loopback test Local Digital Loopback Test V.54 LoopPage Warranty, Service, and Technical Support Service Limited WarrantyRecording Product Information Technical SupportDownloading a File Multi-Tech BBSLogging onto the Multi-Tech BBS Reading a Message About CompuServeLeaving a Message BulletinsAbout the Internet About the Multi-Tech Fax-Back ServiceUpgrading the MT3334HD8 Firmware Using FlashPro to Upgrade FirmwareMT3334HD8 User Guide Appendixes Ctrl Code HEX DEC Appendix a Ascii Conversion ChartTone Dial Frequencies Appendix B Dial Pulses and TonesDial Pulses Figure B-2. Standard Dtmf frequencies Multi-Tech Result Codes &Q0 Appendix C Result Code SummaryStandard AT Result Codes &Q1 Appendix D S-Register Summary Register Unit Range Default DescriptionSets fixed V.34 connect speed = 28800 bps Return Appendix E AT Command SummaryCDn AT Command Summary $Fn Command Values Description Command Values Description $MBn RAn Command Values Description SFn Command Values Description #Vn Breakatcr Setup Appendix F Remote ConfigurationBasic Procedure Changing the Remote Escape Character Changing the PasswordsIndex MT3334HD8 User Guide Index Long space break Pacing, 36, 37, 38 enable/disable, 38 ENQ/ACK Commands Loopback tests, 42, 43, 54, 56 tone detection