Mode 2 (Demand Delayed Mode) Setting Chart

This section provides guidance for using different service settings to achieve the desired capacity. Note: Mode 2 and Mode 3 have the same settings. Mode 3 is NOT recommended for residential use.

 

60 Series

63MAQ1

63BEQ1,2

63MXQ1

63MDQ3

62AMQ1

62APQ1,3,4

62AKQ3

62AJQ3,5

 

Mode 2

Yes

Yes

Yes

No

Yes

No

No

No

 

Capacity

As

As

As

As

 

required

required

required

required

 

 

 

 

 

 

 

96 hour regeneration

Yes or No

Yes or No

Yes or No

Yes or No

 

(if iron present—yes)6

 

 

 

 

 

 

 

 

 

 

#1 Salt Setting

 

 

 

 

 

 

 

 

 

Backwash 1 (minutes)

1

1

16

26

 

Brine/Rinse (minutes)

7

7

7

7

 

Backwash 2 (minutes)

3

3

3

2

 

Capacity (grains) @

5,900 @

5,900 @

8,400 @

5,200 @

 

salt (lb)

1.1 lb

1.1 lb

1.6 lb

1 lb

 

 

 

 

 

 

#2 Salt Setting

 

 

 

 

 

 

 

 

 

Backwash 1 (minutes)

1

1

16

26

 

Brine/Rinse (minutes)

12

12

19

12

 

Backwash 2 (minutes)

3

3

3

2

 

Capacity (grains) @

16,300 @

16,300 @

20,000 @

11,900 @

 

salt (lb)

3.2 lb

3.2 lb

4.2 lb

2.7 lb

 

 

 

 

 

 

#3 Salt Setting

 

 

 

 

 

 

 

 

 

Backwash 1 (minutes)

1

1

17

27

 

Brine/Rinse (minutes)

30

30

47

30

 

Backwash 2 (minutes)

3

3

3

2

 

Capacity (grains) @

26,700 @

26,700 @

38,700 @

23,100 @

 

salt (lb)

6.2 lb

6.2 lb

9.6 lb

6.2 lb

 

 

 

 

 

 

#4 Salt Setting8

 

 

 

 

 

 

 

 

 

Backwash 1 (minutes)

1

1

17

47

 

Brine/Rinse (minutes)

45

45

60

45

 

Backwash 2 (minutes)

3

3

3

2

 

Capacity (grains) @

32,500 @

32,500 @

49,300 @

30,000 @

 

salt (lb)

9.5 lb

9.5 lb

14.4 lb

9.3 lb

 

 

 

 

 

1Models 63MAQ, 63BEQ, 63MXQ, 62AMQ and 62APQ are certified by WQA. All other models are not tested or certified by WQA

2Municipally supplied chlorinated water only.

3NA, See Mode 1 Setting Chart.

4Model has no backwash flow control button or retainer. Must have a minimum of 7 gpm @ 30 psi available for proper backwash. See Mode 1 Setting Chart.

5Calcite will add additional hardness to water before softening.

6If iron is present in water supply, use salt setting #3 or #4.

7If iron is present in the water supply, set Backwash 1 to 7 minutes.

8Do not use this salt setting in California.

WaterMax 60 Series Owner’s Manual