WaterMax® Water Conditioner Specifications

60 Series

63MAQ1

63BEQ1,2

63MXQ1

63MDQ

62AMQ1

62APQ1

62AKQ

62AJQ3

Max Compensated Hardness (gpg)

90

90

110

904

90

90

90

60

Iron (ppm)5 ferrous-clear water

0

0

125

0

125

2-125 ,7

15

5

Maximum ferrous iron reduction6

 

 

 

 

 

 

 

 

Minimum pH (standard units)

7

7

7

7

7

7

7

6.3

Tannin (ppm)

0

0

0

0–2

0

0

0

0

Sulfur (ppm)-SulfurStat

0

0

0

0

0

0-57

0

0

Maximum Chlorine (ppm)

0

3

0

0

0

0

0

0

Filtration-nominal rating (microns)

20

25

20

20

20

20

20

20

Media Amount Compartment #18

1.5 lb

2.0 lb

1.5 lb

1.5 lb

Empty

Empty

Empty

Empty

Media Amount Compartment #28

Empty

0.4 cu.ft.

0.6 cu.ft.

0.3 cu.ft.

6 lb

27 lb

0.4 cu.ft.

0.4 cu.ft.

Media Amount Compartment #3

1.06 cu.ft.

1.06 cu.ft.

1.06 cu.ft.

1.06 cu.ft.

1.06 cu.ft.

1.06 cu.ft.

1.06 cu.ft.

1.06 cu.ft.

Fine Mesh Cation Resin

 

 

 

 

 

 

 

 

Backwash Rate @ min. water pressure

2.49

39

2.49

2.49

59

Empty 9,10

79

79

maximum flow to drain

 

 

 

 

 

 

 

 

Brine Line Flow Control Refill (gpm)

0.5

0.5

0.5

0.5

0.5

0.5

0.5

0.5

Water Pressure (min–max psi)

20–120

20–120

20–120

20–120

20–120

30–120

30–120

30–120

Flow Rate @ 25 psi drop-as tested by

19.5

19.5

17

17

23

19.6

19.6

20.5

Hague

 

 

 

 

 

 

 

 

Flow Rate @ 15 psi drop-as tested by

11

13

10.5

10.5

11.2

10.6

10.6

12.5

Hague

 

 

 

 

 

 

 

 

Pressure Drop @ Service Flow Rate of

11 psi

11 psi

12 psi

12 psi

9 psi

10 psi

10 psi

11 psi

8 gpm

 

 

 

 

 

 

 

 

#1 Setting—Salt lb/grains removed

1.1/5,900

1.1/5,900

1.6/8,400

NA

1/5,200

NA

NA

NA

#2 Setting—Salt lb/grains removed

3.2/16,300

3.2/16,300

4.2/20,000

NA

2.7/11,900

NA

NA

2.7/11,900

#3 Setting—Salt lb/grains removed

6.2/26,700

6.2/26,700

9.6/38,700

8.5/23,100

6.2/23,100

6.2/23,100

6.2/23,100

6.2/23,100

#4 Setting—Salt lb/grains removed

9.5/32,500

9.5/32,500

14.4/49,300

10.7/30,300

9.3/30,000

9.3/29,800

9.3/30,300

9.3/30,300

#1 Salt Setting—Total length of reg. Min/gal

12/13.5

12/16

12/13.5

NA

12/24

NA

NA

NA

#2 Salt Setting—Total length of reg. Min/gal

18/16.5

18/19

26/20.5

NA

18/27

NA

NA

23/70

#3 Salt Setting—Total length of reg. Min/gal

38/26.5

38/29.5

58/36.5

47/31

38/37

44/80

44/80

44/80

#4 Salt Setting—Total length of reg. Min/gal

56/35.5

56/38

74/44.5

64/39.5

58/56

61/89

61/89

61/89

Shipping weight (lb)

135

152

168

152

140

167

160

180

Bacteriostatic-KDF®Process Media*

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

For All Models:

Use clean white pellet or solar salt. Drain Line (Minimum I.D.) 1/2" Height (inches) 38 1/4"

Salt storage capacity: 200 lb, 90 kg

Electrical rating: 115V, 60 cycle Valve Inlet/Outlet 1"

Water Temperature (Min-Max) 40–120 F Floor Space (inches) 15" x 30"

Brine & Rinse total: 0.65 gpm

Brine Draw: 0.25 gpm

Rinse: 0.4 gpm

Iron reduction to 0.3 ppm or less. (Not certified by WQA.)

*Listed with the U.S. EPA as a Bacteriostatic Device U.S. EPA

# 54369-OH-001. Not certified by WQA.

1Models 63MAQ, 63BEQ, 63MXQ, 62AMQ and 62APQ are certified by WQA for barium and radium reduction as verified and substantiated by test data. All other models are not certified by WQA and make no health claims.

2Municipally supplied chlorinated water only.

3Calcite will add additional hardness to water before softening.

4Any hardness over 10 gpg will increase the chance of calcium carbonate precipitation. As the hardness increases so does the chance of this precipitation. Must use citric acid to regenerate along with salt.

5Regeneration every 96 hours is required when iron is present in the raw water supply unless noted otherwise. Use Salt Setting #3 or #4.

6Iron reduction claims limited to 5 ppm in the state of Wisconsin.

7Must have a minimum of 2 ppm iron and a minimum of 200 ppm TDS.

8When adding media in the field, check for proper settings. (See Specifications, above.)

9Rate of flow must be verified at the end of 1/2" I.D. drain line.

10This model has no backwash flow control button or retainer. Must have a minimum of 7 gpm @ 30 psi available for proper backwash.

For the purposes of plumbing appliance sizing, only the rated service flow rate and corresponding pressure loss may be used. Prolonged operation of a water softener at flow rates exceeding the tested service flow rate may compromise performance.