Six-Button Controller, Cont.

Controller Part

Function

LCD Display

Shows the status of the controller

 

 

Normal Operating

Shows

Mode

￿ The amount of soft water remaining until the next automatic regeneration (Each person in

 

the household uses about 75 gallons per day)

 

￿ The number of days until the next regeneration (Mode 1)

 

￿ The current day and time and the flow rate in gallons (or liters) per minute

 

￿ The time of the next scheduled regeneration (If the Regenerate button has been pressed

 

and released)

Customer Setting

Includes setting the time of day, the regeneration time, and the number of people in the household;

Mode

depending on the service settings, this option may not be available

Service Settings

Includes settings such as the language, mode, water hardness, and time of each regeneration

Mode

step. Service Settings must be set before Customer Settings. Otherwise, some values may not be

 

available. Intended for use by qualified service personnel

Water Flowing

Indicates that water is flowing through the appliance; useful for checking for proper plumbing and

Indicator

leaks

Recharge/

Shows regeneration cycle positions during regeneration

Regeneration

 

Status

 

Scroll Back Button

Steps back to a previous parameter setting without the need to scroll forward through all settings

 

 

Change Digit

Used with the Select Digit button to set the value of certain parameters.

Button

Pressing the Change Digit button changes the value under the cursor to the next available value,

 

typically increasing by one until all values have been displayed and the process begins again

Select Digit Button

Moves the cursor when setting parameters

 

1. Press and release the Select Digit button to move the cursor one digit to the right of the

 

parameter to be changed

 

2. When the cursor is at the extreme right position, press the Select Digit button again to

 

reset the cursor to the extreme left position

Service Settings

Enters the Service Setting programming mode—for use by Hague dealer. See Service Settings

Button

 

Regenerate Button

Used to start an immediate regeneration

 

 

Customer

Enters the Customer Setting programming mode. See Customer Settings

Settings/Next

 

Button

 