Service Settings
To program Service settings on the 60 Series controller, press and hold the Service Settings button while “Service Settings” is displayed until “Set Language English” is displayed. The Next function becomes active on the Customer Settings/Next button. Use the Next button to step through parameters that can be set. Programming Service Settings is similar to programming Customer Settings (see Customer Settings for programming details). The values that can be set are listed below. (Metric values are in parentheses.)
Note: The Service Settings must be set before the Customer Settings.
Display |
| Meaning | Possible Values | Comments |
Set Language English | Set the language of the display | Set Language English |
| |
|
|
| Entrer Langue Francais |
|
|
|
| Entre La Lengua Español |
|
|
|
| Sprache Entr. Deutsch |
|
|
|
| Ambienti Lingua Italiano |
|
Units |
| Units of measure | English |
|
English |
|
| Metric |
|
Show |
| Enables entry to the history file or | Yes | Enter history file |
History | Yes | bypass of the history file | No | Bypass history file |
| (Hist) | Displays the current software | Cannot be set | Displays only when History |
Soft. v. # 2.04 |
| version |
| is set to Yes |
Install | (Hist) | Installation date of the appliance |
| Displays only when History |
Date | 000000 | (MMDDYY) | 000000 to 999999 | is set to Yes |
Number of | (Hist) | Record of the number of people in | 000 to 999 | Displays only when History |
People | 000 | the household | (should match Customer | is set to Yes |
|
|
| Settings) |
|
Hardness | (Hist) | Record of tested water |
| Display only when History |
Grains | 000 | characteristics | 000 to 999 ppm (mg/L) | is set to Yes |
Iron | (Hist) |
|
|
|
ppm | 000 |
| 000 to 999 ppm (mg/L) |
|
Manganese | (Hist) |
|
|
|
ppm | 000 |
| 000 to 999 ppm (mg/L) |
|
Chlorine | (Hist) |
|
|
|
ppm | 000 |
| 000 to 999 ppm (mg/L) |
|
Sulfur | (Hist) |
|
|
|
ppm | 000 |
| 000 to 999 ppm (mg/L) |
|
pH | (Hist) |
| 00.0 to 99.9 |
|
00.0 |
|
| ||
Iron | (Hist) |
| Yes or No |
|
Bacteria | Yes |
|
| |
|
|
|
|
|
Total | (Hist) | Total number of regenerations the | Cannot be reset | Displays only when History |
Regens | 00000 | appliance has gone through | is set to Yes | |
Total | (Hist) | Total amount of water that has | Cannot be reset | Displays only when History |
Gallons | 00000000 | passed through the appliance | is set to Yes | |
Model | (Hist) | Model number of the appliance | 00AAA to 99ZZZ | Displays only when History |
Number | 00AAA |
|
| is set to Yes |
Save |
| Saves history values | Yes | Displays only when History |
History | Yes |
| No | is set to Yes |
WaterMax 60 Series Owner’s Manual | 11/10/2008 | 15 |