Hague Quality Water Intl 60 SERIES manual Troubleshooting

Models: 60 SERIES

1 52
Download 52 pages 59.67 Kb
Page 43
Image 43

Troubleshooting, Cont.

Problem

Possible Cause

Solution

Appliance stays in

Controller not attached properly

Make sure the controller is pushed all the way

regeneration

 

onto the drive end cap

 

Defective magnet disk

Replace magnet disk

 

Foreign object in valve body

Remove foreign object(s) from the valve body

 

Broken valve assembly. Motor running

Repair the drive end cap

Excess water in brine

Restricted, frozen, or pinched drain line

Remove restriction, thaw, or straighten drain

tank

 

line

 

Plugged brine line, brine line flow control, or

Clean flow control, air check/draw tube, and

 

air check/draw tube

brine line. Clean any sediment from the brine

 

Plugged injector assembly

cabinet

 

Clean or replace injector. Replace throat if

 

 

removed

Not regenerating in

Magnet disk defective

Replace magnet disk

proper sequence

Defective controller

Replace controller

Salty water (pink water

Plugged injector

Clean injector screen, nozzle, and throat

from 61AAN iron filter)

Low water pressure

Maintain minimum pressure of 30 psi

 

Drain line or flow control is restricted

Remove restriction

 

Brine line restricted or crimped

Remove restriction, replace if crimped

 

Excessive amount of water in brine cabinet

Verify correct water level relative to salt

 

 

setting. Check brine line and fittings for loose

 

Insufficient rinse time

connections

 

Check mode setting chart for proper brine

 

Intermittent pressure drop from feed source

rinse time. Adjust time, if necessary

 

Install check valve on the inlet water line to the

 

Brine valve drips water back to brine tank

appliance (Check local plumbing codes first)

 

Clean brine valve housing, replace piston

 

 

assembly

WaterMax 60 Series Owner’s Manual

11/10/2008

43

Page 43
Image 43
Hague Quality Water Intl 60 SERIES manual Troubleshooting