Hague Quality Water Intl 60 SERIES manual Mode 1 Timer Mode Setting Chart, 62AKQ

Models: 60 SERIES

1 52
Download 52 pages 59.67 Kb
Page 19
Image 19

Service Settings, Cont.

Mode 1 (Timer Mode) Setting Chart

This section provides guidance for using different service settings to achieve the desired capacity.

60 Series

63MAQ1

63BEQ1,2

63MXQ1

63MDQ

62AMQ1

62APQ1,3,4

62AKQ

62AJQ5

Mode 1

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Regeneration Frequency

As

As

As

1 or 2

As

1 or 2

1 or 2

1 or 2

required

required

required

days

required

days

days

days

 

96 hour regeneration

Yes

Yes

(if iron present—yes)6

 

 

 

 

 

 

 

 

#1 Salt Setting

 

 

 

 

 

 

 

 

Backwash 1 (minutes)

1

1

16

26

Brine/Rinse (minutes)

7

7

7

7

Backwash 2 (minutes)

3

3

3

2

Capacity (grains) @

5,900 @

5,900 @

8,400 @

5,200 @

salt (lb)

1.1 lb

1.1 lb

1.6 lb

1 lb

 

 

 

 

#2 Salt Setting

 

 

 

 

 

 

 

 

Backwash 1 (minutes)

1

1

16

26

76

Brine/Rinse (minutes)

12

12

19

12

12

Backwash 2 (minutes)

3

3

3

2

2

Capacity (grains) @

16,300 @

16,300 @

20,000 @

11,900 @

11,900 @

salt (lb)

3.2 lb

3.2 lb

4.2 lb

2.7 lb

2.7 lb

 

 

 

#3 Salt Setting

 

 

 

 

 

 

 

 

Backwash 1 (minutes)

1

1

17

1

27

7

7

7

Brine/Rinse (minutes)

30

30

47

38

30

30

30

30

Backwash 2 (minutes)

3

3

3

3

2

2

2

2

Capacity (grains) @

26,700 @

26,700 @

38,700 @

23,100 @

23,100 @

23,100 @

23,100 @

23,100 @

salt (lb)

6.2 lb

6.2 lb

9.6 lb

8.5 lb

6.2 lb

6.2 lb

6.2 lb

6.2 lb

#4 Salt Setting8

 

 

 

 

 

 

 

 

Backwash 1 (minutes)

1

1

17

1

47

7

7

7

Brine/Rinse (minutes)

45

45

60

45

45

45

45

45

Backwash 2 (minutes)

3

3

3

3

2

2

2

2

Capacity (grains) @

32,500 @

32,500 @

49,300 @

30,300 @

30,000@

29,800 @

30,300 @

30,300 @

salt (lb)

9.5 lb

9.5 lb

14.4 lb

10.7 lb

9.3 lb

9.3 lb

9.3 lb

9.3 lb

1Models 63MAQ, 63BEQ, 63MXQ, 62AMQ and 62APQ are certified by WQA. All other models are not tested or certified by WQA.

2Municipally supplied chlorinated water only.

3Must have a minimum of 2 ppm iron and a minimum of 200 ppm TDS. See Specifications.

4Model has no backwash flow control button or retainer. Must have a minimum of 7 gpm @ 30 psi available for proper backwash.

5Calcite will add additional hardness to water before softening.

6If iron is present in water supply, use salt setting #3 or #4.

7If iron is present in the water supply, set Backwash 1 to 7 minutes.

8Do not use this salt setting in California.

WaterMax 60 Series Owner’s Manual