Multi-Tech Systems MT3334HD8 manual Logging onto the Multi-Tech BBS, Downloading a File

Page 68

MT3334HD8 User Guide

The Multi-Tech BBS

Multi-Tech maintains a bulletin board system (BBS) for its customers. Information available from the BBS includes new product information, product upgrade data, and problem-solving tips. There is also a - message service that lets you request additional information. The phone number for the Multi-Tech BBS is (800) 392-2432 (USA and Canada) or (612) 785-3702 (local and international).

The BBS can be accessed by any asynchronous modem operating at 1200 bps to 33,600 bps at a setting of 8 bits, no parity, and 1 stop bit (8-N-1).

Logging onto the Multi-Tech BBS

To log on to the Multi-Tech BBS, perform the following steps:

1.Set your communications program to 8-N-1.

2.Dial our BBS at (800) 392-2432 (USA and Canada) or (612) 785-3702 (international and local).

3.At the prompts, type your first name, last name, and password; then press ENTER. If you are a first time caller, the BBS will ask if your name is spelled correctly. If you answer yes, a questionnaire will appear. You must complete the questionnaire to use the BBS on your first call.

4.Press ENTER until the Main Menu appears. From the Main Menu you have access to three main areas: the Files Menu, the Message Menu, and Bulletins. For help on menu commands, type ?.

Downloading a File

If you know the file name

1.From the Main Menu, type F to access the Files Menu, then type D.

2.Enter the name of the file you wish to download from the BBS.

3.If a password is required, enter the password.

4.Answer Y or N to the automatic logoff question.

5.Select a file transfer protocol by typing the indicated letter, such as Z for Zmodem (the recommended protocol).

6.If you select Zmodem, the transfer will begin automatically. If you select another protocol, you may have to initiate the transfer yourself. (In most datacomm programs, the PAGE DOWN key initiates the download.)

If you don’t know the file name

1.From the Main Menu, type F to access the Files Menu. For a list of file areas, type L twice. (If you do not type the second L, you will list all of the files on the BBS.)

2.Mark the file areas you would like to examine by typing each file area’s list number and pressing

ENTER.

3.Enter L to list all the files in the selected file areas. Enter C to go forward in the file list and P to go back.

4.Mark one or more files for download by entering M, the list numbers of the files, and pressing

ENTER.

5.Enter D. You will see a list of the files you have marked. Enter E if you would like to edit the list; otherwise enter D again to start the download process.

62

CommPlete Communications Server

Image 68
Contents MT3334HD8 Modem User Guide Multi-Tech Systems, Inc Woodale Drive Mounds View, Minnesota CommPlete Communications Server FCC Fax Warning Canadian Limitations NoticeTable of Contents Testing the MT3334HD8 Warranty, Service, and Technical SupportAppendix D Appendix FIntroduction LED Indicators Power SuppliesIntroduction Manual OrganizationInstallation Technical Specifications Data Rates ModemIntroduction 2400 & 1200 bps MT3334HD8 User Guide Power Installation Safety Warnings MT3334HD8 modem cardPre-Installation Notes Installation ProcedurePage AT Commands Modes of Operation Working with AT CommandsCommand Structure Command Editing AT Commands by Function $BA Dialing Commands Dial Modifier CommandsDs Dial Continuous RedialPulse or Tone Dialing Wait for New Dial ToneRn Reverse Originate/Answer Mode Return to Command Mode After DialingDialing Pause Flash On-HookPhone Number Memory Commands @ Quiet AnswerCall Card Tone Detect DsNd Store a Phone NumberConfiguration Storage and Recall Commands Wn Store ConfigurationNdNe Number Linking List Stored Telephone NumbersReset Modem Modem Response Result Code CommandsFn Load Default Configuration Echo Command Mode Characters Result Codes Verbose/Terse Online Connection Commands An Answerback#An Auto Speed Detection Bn Answer ToneDTn Dtmf Detection DCn AT Command ControlCDn Cleardown at Disconnect #Fn Fallback Modes Gn Guard TonesHn Busy-Out After Disconnect Pn Set Pulse-Dial Ratios#Tn Trellis-Coded Modulation RDn Square Wave Ring Detect$Tn Calling Tone Commands Fn Echo Canceler Frequency Offset CompensationYn Long Space Disconnect RAn Asymmetric Bit RateDn Data Terminal Ready Control RS-232 Interface CommandsCn Carrier Detect Control Rn Clear to Send Control Sn Data Set Ready ControlRFn CTS/RTS Interaction Control SFn DSR/CD Interaction ControlError Correction and Data Compression Commands En Error Correction Modes#Ln V.42 Error Correction Modes En Data Compression$An Auto-Reliable Buffering $En V.42 Error Correction at 300 bps$Fn Auto-Reliable Fallback Character Enable/Disable $Rn Retransmit Count Speed Conversion Commands$BAn Baud Adjust $MBn Modem Baud Rate $SBn Serial Port Baud RateImmediate Action Commands Repeat Last CommandInquire Product Code L5, L7 List Current Operating ParametersFlow Control Commands E3 Flow Control Disable En Non-Error Correction Mode Flow ControlE4 Hardware Flow Control E5 XON/XOFF Flow ControlEn Pacing Computer-Initiated Flow Control #Xn Number of Xoff Characters SentForce Answer Mode Escape Sequences+++ATCR In-Band Escape Sequence Breakatcr Out-of-Band Escape SequenceRemote Configuration Commands Atcr Remote Configuration Escape Sequence#Ixxxxxx Change Login Password Go Back OnlineLine Probe Commands #Syyyyyy Change Setup PasswordDPn Read Line Probe Data DFn Format Line Probe DataDiagnostic Commands Tn Respond to Remote Digital Loopback SignalRP Immediate Line Probe Ln Display Line Probe DataUn Loopback Test Modes MT3334HD8 User Guide Registers Registers S0 Number of Rings Until Modem AnswersS1 Ring Count S2 Escape Code CharacterS7 Time for Carrier Abort Timer S4 Line Feed CharacterS5 Backspace Character S6 Wait Time for Dial ToneS10 Carrier Loss Disconnect Delay Time S13 Remote Configuration Escape CharacterS9 Carrier Detect Response Time S11 Tone Dialing Spacing and DurationS30 Inactivity Timer S34 Command Buffer Length After Online Escape SequenceS24 PBX/CBX Disconnect Drop Time for DSR/CTS/CD S25 DTR Dropout TimeS94 Out-of-Service Time S37 DTR Busy-In TimeS43 Force V.34 Connect Speed S48 Maximum V.34 Connect SpeedAT Commands that Affect S-Registers Reading and Assigning S-Register ValuesExamples of Assigning Values Examples of Reading ValuesAT&E2$SP1#L3$R0$MB19200$SB115200$EB1S0=10&W0CR Testing the MT3334HD8 Test procedure Local Analog Loopback Test V.54 LoopTesting the MT3334HD8 Remote Digital Loopback Test V.54 LoopDial the remote modem and establish your online connection Local Digital Loopback Test V.54 Loop Local digital loopback testPage Warranty, Service, and Technical Support Limited Warranty ServiceTechnical Support Recording Product InformationDownloading a File Multi-Tech BBSLogging onto the Multi-Tech BBS About CompuServe Reading a MessageLeaving a Message BulletinsAbout the Multi-Tech Fax-Back Service About the InternetUsing FlashPro to Upgrade Firmware Upgrading the MT3334HD8 FirmwareMT3334HD8 User Guide Appendixes Appendix a Ascii Conversion Chart Ctrl Code HEX DECTone Dial Frequencies Appendix B Dial Pulses and TonesDial Pulses Figure B-2. Standard Dtmf frequencies Appendix C Result Code Summary Multi-Tech Result Codes &Q0Standard AT Result Codes &Q1 Register Unit Range Default Description Appendix D S-Register SummarySets fixed V.34 connect speed = 28800 bps Appendix E AT Command Summary ReturnCDn AT Command Summary $Fn Command Values Description Command Values Description $MBn RAn Command Values Description SFn Command Values Description #Vn Breakatcr Setup Appendix F Remote ConfigurationBasic Procedure Changing the Passwords Changing the Remote Escape CharacterIndex MT3334HD8 User Guide Index Long space break Pacing, 36, 37, 38 enable/disable, 38 ENQ/ACK Commands Loopback tests, 42, 43, 54, 56 tone detection