Multi-Tech Systems MT3334HD8 manual Command Values Description SFn

Page 88

MT3334HD8 User Guide

Command

Values

Description

 

&SFn

n = 0 or 1

DSR/CD Interaction Control

 

*** &SF0 Select DSR to follow CD.

 

 

&SF1 Select DSR to be independent.

$SBn

n = speed

Serial Port Baud Rate

 

Baud Adjust

$SB300

Select 300 bps at serial port.

 

($BA) must

$SB1200 Select 1200 bps at serial port.

 

be off.

$SB2400 Select 2400 bps at serial port.

 

 

$SB4800 Select 4800 bps at serial port.

 

 

$SB9600 Select 9600 bps at serial port.

 

 

$SB12000 Select 12,000 bps at serial port.

 

 

$SB19200 Select 19,200 bps at serial port.

 

 

$SB38400 Select 38,400 bps at serial port.

 

 

$SB57600 Select 57,600 bps at serial port.

 

***

$SB115200

Select 115,200 bps at serial port.

#Sy

y = password

Enter Setup Password

 

 

Password is case sensitive.

#S=y

y = password

Store Setup Password

 

 

Password must be 6–10 characters long, and may

 

 

consist of any keyboard characters.

T

In dialing

Tone-Dial

 

 

command

Modem tone-dials numbers following the T.

&Tn

n = 4 or 5

Respond to Remote Digital Loopback Signal

 

 

&T4

Enable response to remote digital loopback

 

 

 

signal.

 

 

***

&T5

Disable response to remote digital loopback

 

 

 

signal.

 

$Tn

n = 0 or 1

Calling Tone

 

 

$T0

Enable calling tone.

 

***

$T1

Disable calling tone.

#Tn

n = 0 or 1

Trellis-Coded Modulation

 

 

#T0

Disable trellis-coded modulation.

 

***

#T1

Enable trellis-coded modulation.

Un

n = 0–3

Loopback Test Modes

 

 

U0

Enable analog loop originate mode.

 

 

U1

Enable analog loop answer mode.

 

 

U2

Enable remote digital loopback mode.

 

 

U3

Enable local digital loopback mode.

Vn

n = 0 or 1

Result Codes (Verbose/Terse)

 

 

V0

Result codes sent as digits (terse response).

 

*** V1

Result codes sent as words (verbose

 

 

 

response).

82

CommPlete Communications Server

Image 88
Contents MT3334HD8 Modem User Guide Multi-Tech Systems, Inc Woodale Drive Mounds View, Minnesota CommPlete Communications Server FCC Fax Warning Canadian Limitations NoticeTable of Contents Testing the MT3334HD8 Warranty, Service, and Technical SupportAppendix D Appendix FIntroduction LED Indicators Power SuppliesIntroduction Manual OrganizationInstallation Technical Specifications Data Rates ModemIntroduction 2400 & 1200 bps MT3334HD8 User Guide Power Installation Safety Warnings MT3334HD8 modem cardPre-Installation Notes Installation ProcedurePage AT Commands Command Structure Working with AT CommandsModes of Operation Command Editing AT Commands by Function $BA Dialing Commands Dial Modifier CommandsDs Dial Continuous RedialPulse or Tone Dialing Wait for New Dial ToneRn Reverse Originate/Answer Mode Return to Command Mode After DialingDialing Pause Flash On-HookPhone Number Memory Commands @ Quiet AnswerCall Card Tone Detect DsNd Store a Phone NumberConfiguration Storage and Recall Commands Wn Store ConfigurationNdNe Number Linking List Stored Telephone NumbersFn Load Default Configuration Modem Response Result Code CommandsReset Modem Echo Command Mode Characters Result Codes Verbose/Terse Online Connection Commands An Answerback#An Auto Speed Detection Bn Answer ToneCDn Cleardown at Disconnect DCn AT Command ControlDTn Dtmf Detection #Fn Fallback Modes Gn Guard TonesHn Busy-Out After Disconnect Pn Set Pulse-Dial Ratios$Tn Calling Tone RDn Square Wave Ring Detect#Tn Trellis-Coded Modulation Commands Fn Echo Canceler Frequency Offset CompensationYn Long Space Disconnect RAn Asymmetric Bit RateCn Carrier Detect Control RS-232 Interface CommandsDn Data Terminal Ready Control Rn Clear to Send Control Sn Data Set Ready ControlRFn CTS/RTS Interaction Control SFn DSR/CD Interaction ControlError Correction and Data Compression Commands En Error Correction Modes#Ln V.42 Error Correction Modes En Data Compression$Fn Auto-Reliable Fallback Character Enable/Disable $En V.42 Error Correction at 300 bps$An Auto-Reliable Buffering $BAn Baud Adjust Speed Conversion Commands$Rn Retransmit Count $MBn Modem Baud Rate $SBn Serial Port Baud RateImmediate Action Commands Repeat Last CommandInquire Product Code L5, L7 List Current Operating ParametersFlow Control Commands E3 Flow Control Disable En Non-Error Correction Mode Flow ControlE4 Hardware Flow Control E5 XON/XOFF Flow ControlEn Pacing Computer-Initiated Flow Control #Xn Number of Xoff Characters SentForce Answer Mode Escape Sequences+++ATCR In-Band Escape Sequence Breakatcr Out-of-Band Escape SequenceRemote Configuration Commands Atcr Remote Configuration Escape Sequence#Ixxxxxx Change Login Password Go Back OnlineLine Probe Commands #Syyyyyy Change Setup PasswordDPn Read Line Probe Data DFn Format Line Probe DataDiagnostic Commands Tn Respond to Remote Digital Loopback SignalRP Immediate Line Probe Ln Display Line Probe DataUn Loopback Test Modes MT3334HD8 User Guide Registers Registers S0 Number of Rings Until Modem AnswersS1 Ring Count S2 Escape Code CharacterS7 Time for Carrier Abort Timer S4 Line Feed CharacterS5 Backspace Character S6 Wait Time for Dial ToneS10 Carrier Loss Disconnect Delay Time S13 Remote Configuration Escape CharacterS9 Carrier Detect Response Time S11 Tone Dialing Spacing and DurationS30 Inactivity Timer S34 Command Buffer Length After Online Escape SequenceS24 PBX/CBX Disconnect Drop Time for DSR/CTS/CD S25 DTR Dropout TimeS94 Out-of-Service Time S37 DTR Busy-In TimeS43 Force V.34 Connect Speed S48 Maximum V.34 Connect SpeedAT Commands that Affect S-Registers Reading and Assigning S-Register ValuesExamples of Assigning Values Examples of Reading ValuesAT&E2$SP1#L3$R0$MB19200$SB115200$EB1S0=10&W0CR Testing the MT3334HD8 Test procedure Local Analog Loopback Test V.54 LoopTesting the MT3334HD8 Remote Digital Loopback Test V.54 LoopDial the remote modem and establish your online connection Local Digital Loopback Test V.54 Loop Local digital loopback testPage Warranty, Service, and Technical Support Limited Warranty ServiceTechnical Support Recording Product InformationLogging onto the Multi-Tech BBS Multi-Tech BBSDownloading a File About CompuServe Reading a MessageLeaving a Message BulletinsAbout the Multi-Tech Fax-Back Service About the InternetUsing FlashPro to Upgrade Firmware Upgrading the MT3334HD8 FirmwareMT3334HD8 User Guide Appendixes Appendix a Ascii Conversion Chart Ctrl Code HEX DECDial Pulses Appendix B Dial Pulses and TonesTone Dial Frequencies Figure B-2. Standard Dtmf frequencies Appendix C Result Code Summary Multi-Tech Result Codes &Q0Standard AT Result Codes &Q1 Register Unit Range Default Description Appendix D S-Register SummarySets fixed V.34 connect speed = 28800 bps Appendix E AT Command Summary ReturnCDn AT Command Summary $Fn Command Values Description Command Values Description $MBn RAn Command Values Description SFn Command Values Description #Vn Breakatcr Basic Procedure Appendix F Remote ConfigurationSetup Changing the Passwords Changing the Remote Escape CharacterIndex MT3334HD8 User Guide Index Long space break Pacing, 36, 37, 38 enable/disable, 38 ENQ/ACK Commands Loopback tests, 42, 43, 54, 56 tone detection