Multi-Tech Systems MT5634ZPX-PCI-V92 manual MultiModemZPX User Guide Index

Page 83

MultiModemZPX User Guide

Index

Symbols

56K operation

digital loss when used with PBX 42

disabling the auto rate 42 maximum connect speed 41 mode selection 42

A

abort timer 40

Adaptive Answer Result Code

Enable command 31 analog loopback test 63–64 Answer command 23 Asynchronous Communications

Mode command 27 AT commands 22–44

#S 38 #S= 38

%%%AT 39 %A 31 %B 31 %C 31 %E 31 &&S 28 &C 26 &D 27, 52 &E 27

&F 16, 27 &G 27 &K 27 &Q 27, 52 &S 28 &T 28 &V 28

&W 16, 28, 46, 47 &Z= 28

+++AT 39 +DCS= 32 +DR= 32 +DS44= 32 +ES= 33 +MS= 34 +MS=? 32, 34 +MS? 33, 34 +PCW= 35 +PIG= 36 +PMH= 36 +PMHF 36 +PMHR= 36 +PMHT= 37 +PQC= 37 +VCID= 38 +VDR= 38 -C 31

\A 28 \B 29

\J 29 \K 29 \N 30 \Q 30 \T 30 \V 30 \X 30

A23

A/ 23 AT 23

B23

D23 definition 22 descriptions 23–39 DS= 24

E24

F24 format 22

H24

I24

M25

N25

O25, 46, 47

P25

Q25 S= 25 S? 25

T26

V26

W26

X26 Z 26

attention code 23 autoanswer 22, 40, 52 autobaud 16

B

backspace character, setting 40 baud rate 16

Bell 212A mode 23 blacklisting 31

Break Control command 29 break signal 29

C

call waiting 35, 51

Call Waiting Enable command 35 Caller ID 2, 16, 38, 40, 52, 53 Caller ID Selection command 38 Canadian regulations 58–60 carriage return character 40 carrier loss disconnect time, setting

40

COM Port assignment 9 comma, setting pause time 40 command mode 22 command string 22

communication programs 16, 22, 49

Communication Standard command 23

compression, data 32, 52 configuration, storing a 16, 28 configuring for your country 15 configuring software 16 connect messages 16, 43 country code, displaying 24 country configuration 15

D

Data Buffer Control command 29 data buffering 27

data calling tone 40

Data Calling Tone command 31 Data Carrier Detect command 26 data compression 32, 52

data mode 22, 25, 64

Data Set Ready Control command 28 Data Terminal Ready command 27 DCD Control command 26 default settings 16, 27

diagnostic information, displaying 24 Dial command 23

Dial Stored Telephone Number command 24

dial string modifiers 23 Dial-Up Networking 19–20 dialing tones 40

digital loopback tests 64–66 disconnect delay 40

Display Current Settings command 28

Distinctive Ring command 38 DSR Control command 28 DTE rate 16

DTR (Data Terminal Ready) Control command 27, 52

E

Echo Command Mode Characters command 24

Echo Online Data Characters command 24

Enable Synchronous Buffered Mode command 33

ENTER key 23

Enter Setup Password command 38 error control, setting 40, 42

error correction, disabling 64 Error Correction Mode Selection

command 30 escape character 40 escape sequence 22, 39

78

Image 83
Contents Page Record of Revisions Introduction Solving Problems Appendix G Installing Under SCO OpenServer Introduction Product Description What Is in Your Modem Package?Introduction Installation You supply Safety WarningsWhat You Will Need We supplyInstall the MultiModemZPX in your Computer Phone Connection Make the External ConnectionsLine Connection Sound Card and Speaker Connections Microphone ConnectionWindows 98/Me Install the Modem DriverWindows Changing the Windows 95/98/Me COM port assignment Verifying the Windows 95/98/Me Configuration Windows NT If Dial-Up Networking is not installedIf Dial-Up Networking is already installed Verifying the Windows NT Configuration Viewing system resources Global Wizard Utility Configure the Modem for Your CountryAT Commands Install and Configure Your Software Operation Connecting to the Internet Configuring the ModemPhoneTools Features Sending a Fax Dial-Up NetworkingReferences AT Commands Registers Result Codes Introduction Answer AT CommandsRepeat Last Command Communication Standard SettingHook Control Echo Command Mode CharactersDS=n Dial Stored Telephone Number Echo Online Data CharactersModulation Handshake Monitor Speaker ModeReturn Online to Data Mode Result Codes Enable/DisableResult Code Options Modem ResetTone Dialing Result Code FormatXON/XOFF Pacing Control Load Factory SettingsAsynchronous Communications Mode Data Terminal Ready DTR ControlStore Dialing Command Test CommandsDisplay Current Settings Store Current Configuration\Kn Break Control \Bn Transmit Break\Jn Data Buffer Control \V n Protocol Result Code \Nn Error Correction Mode Selection\Tn Inactivity Timer \Qn Flow Control Selection42bis Compression Control Adaptive Answer Result Code EnableData Calling Tone View Numbers in BlacklistData Compression Reporting Command +DCS=x,y Select V.44 Data CompressionCommand +DS44=n V.44 Data Compression Subparameters Enable Synchronous Buffered ModeMod Modulation SelectionCommand +PCW= n Call Waiting Enable Modem Hook Flash Modem on Hold EnableCommand +PMHR=n Modem on Hold Initiate PCM Upstream IgnoreQuick Connect Control Command +PMHT=n Modem on Hold Timer#S=x Store Setup Password Command +VCID=n Caller ID SelectionCommand +VDR=x, y Distinctive Ring Report #Sx Enter Setup PasswordCommand %%%ATCR Remote Configuration Escape Sequence Command +++ATCR Escape SequenceRegisters Register Unit Range Default DescriptionValue Rate Value SpeedValue Digital loss Bit 56K modeTerse Verbose Description Result CodesDelayed Remote Configuration To Change the Setup Password Basic ProcedureSetup To Change the Remote Escape Character Solving Problems Modem Does Not Respond to Commands Modem Cannot Connect When Dialing ModemDisconnects While Online MultiModemZPX User Guide Voice Functions Don’t Work There Are Garbage Characters on the MonitorModem Doesn’t Work with Caller ID Fax and DataSoftware Can’t Run at the Same TimeSpeakerphone Test Voice Mail TestLoopback Test Appendixes FCC Part 68 Telecom Appendix a Regulatory ComplianceFax Branding Statement FCC PartProtection Against Contact with TNV Circuit Canadian Limitations NoticeIndustry Canada New Zealand Telecom Warning Notice EMC, Safety, and R&TTE Directive ComplianceInternational Modem Restrictions South African NoticeAppendix B Technical Specifications Command Buffer Local Analog Loopback Test V.54 Loop Test procedureFigure C-2. Remote digital loopback test Remote Digital Loopback Test V.54 LoopFigure C-3. Local digital loopback test Local Digital Loopback Test V.54 LoopMultiModemZPX User Guide Loopback Tests Canadian Customers Limited WarrantyOnline Warranty Registration Service International Distributors International Customers outside U.S.A. and CanadaInternet Sites Technical SupportIdentify the Modem Firmware Upgrade OverviewDocument and Clear Your Stored Paramenters Download the Upgrade FileExtract the Upgrade Files Identify the Current Firmware VersionRestore Your Parameters Upgrade the Modem’s FirmwarePC port Linux port InstallationStandard Linux Serial Port Definitions Using the Modem to Call the Internet Using the Terminal Program Minicom to Verify OperationAnswering Calls Calling the ISPAppendix G Installing Under SCO OpenServer Index MultiModemZPX User Guide Index MultiModemZPX User Guide Index MultiModemZPX User Guide Index

MT5634ZPX-PCI-V92 specifications

The Multi-Tech Systems MT5634ZPX-PCI-V92 is a high-performance V.92 data/fax modem designed to enhance communication capabilities in various applications. This modem is particularly well-suited for commercial and industrial environments where reliable connectivity is crucial.

One of the standout features of the MT5634ZPX-PCI-V92 is its support for the V.92 protocol, which allows for quicker uploads and improved connection speeds compared to earlier standards. It offers download speeds of up to 56 Kbps and upload speeds of up to 48 Kbps, making it an excellent choice for businesses that rely on time-sensitive data transmission. The modem's ability to maintain reliable connections even over noisy telephone lines is a critical aspect of its design, ensuring that users can depend on it for essential communications.

The MT5634ZPX-PCI-V92 also includes advanced error correction and data compression technologies, such as MNP 4 and V.42bis. These technologies work together to ensure data integrity during transfers and to maximize throughput, enabling users to send larger files without compromising quality or speed. Additionally, the modem features a robust fax capability, supporting both analog and digital fax transmissions, which is vital for businesses that frequently deal with document sharing.

A notable characteristic of the MT5634ZPX-PCI-V92 modem is its PCI interface, which allows for easy integration into desktop systems. This plug-and-play capability simplifies installation and setup, making it accessible for users with varying levels of technical expertise. The modem is built on a reliable hardware platform, characterized by its durable components, making it ideal for environments where long-term use is expected.

Moreover, the MT5634ZPX-PCI-V92 comes with comprehensive driver support for various operating systems, including Windows and Linux, ensuring compatibility with a wide range of applications. With its combination of speed, reliability, and ease of use, the Multi-Tech Systems MT5634ZPX-PCI-V92 modem remains a popular option for businesses looking to maintain effective communication channels through dial-up connectivity. Whether for data transmission or faxing, it stands as a solid choice for organizations that require dependable performance in a compact form factor.