Multi-Tech Systems MT5634ZPX-PCI-V92 manual Local Digital Loopback Test V.54 Loop

Page 70

MultiModemZPX User Guide

C Loopback Tests

6.Enter data from your keyboard. For this test, typing multiple uppercase U char- acters is a good way to send an alternating test pattern of binary ones and zeroes. Data received by the remote modem enters its analog receiver, is converted to digital data, is reconverted into analog, and then is transmitted back to your modem. Your modem passes this test if the characters received on your monitor are the same as the characters entered from your keyboard.

7.To exit the test, type the escape sequence +++AT and press ENTER. This puts the modem in online command mode. The modem should respond with an OK mes- sage. If you wish to stay on line with the remote modem for normal data trans- mission, type AT&T and press ENTER to exit the test, then type ATO and press ENTER to return on line. If you wish to terminate the call, type ATH and press ENTER to hang up.

Local Digital Loopback Test (V.54 Loop 2)

The local digital loopback test is identical to the remote digital loopback test with one exception. Instead of using your modem to signal a remote modem to place it- self in digital loopback mode, your modem is placed in digital loopback mode while the remote modem is not. Data is entered and transmitted from the remote modem, sent across the phone line to your modem, and looped back to the remote modem.

AT&T3

OK

UUUUUUUUUUU UUU

Digital Analog

Analog Digital

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Computer or Terminal Local MultiModem

Remote MultiModem Computer or Terminal

Figure C-3. Local digital loopback test.

Test procedure

1.Using your communication program, set the baud rate to 9600 and go into ter- minal mode. Type AT and press ENTER; you should get an OK message.

2.Dial the remote modem and establish your online connection.

3.Type the escape sequence +++AT and press ENTER to bring your modem into online command mode.

4.Type AT&T3 and press ENTER. Once you receive an OK message from your mo- dem (if responses are enabled), your modem is placed in digital loopback mode.

5.Have someone enter data from the remote keyboard. For this test, typing multiple uppercase U characters is a good way to send an alternating test pattern of binary ones and zeros. The data received by your modem enters its analog receiver, is converted to digital data, is reconverted into analog, and then is transmitted back to the remote modem. Your modem passes this test if the characters received on the remote monitor are the same as the characters entered from the remote keyboard.

65

Image 70
Contents Page Record of Revisions Introduction Solving Problems Appendix G Installing Under SCO OpenServer Introduction Introduction What Is in Your Modem Package?Product Description Installation We supply Safety WarningsWhat You Will Need You supplyInstall the MultiModemZPX in your Computer Line Connection Make the External ConnectionsPhone Connection Microphone Connection Sound Card and Speaker ConnectionsWindows Install the Modem DriverWindows 98/Me Changing the Windows 95/98/Me COM port assignment Verifying the Windows 95/98/Me Configuration If Dial-Up Networking is not installed Windows NTIf Dial-Up Networking is already installed Verifying the Windows NT Configuration Viewing system resources AT Commands Configure the Modem for Your CountryGlobal Wizard Utility Install and Configure Your Software Operation PhoneTools Features Configuring the ModemConnecting to the Internet Dial-Up Networking Sending a FaxReferences AT Commands Registers Result Codes Introduction Communication Standard Setting AT CommandsRepeat Last Command AnswerEcho Online Data Characters Echo Command Mode CharactersDS=n Dial Stored Telephone Number Hook ControlResult Codes Enable/Disable Monitor Speaker ModeReturn Online to Data Mode Modulation HandshakeResult Code Format Modem ResetTone Dialing Result Code OptionsData Terminal Ready DTR Control Load Factory SettingsAsynchronous Communications Mode XON/XOFF Pacing ControlStore Current Configuration Test CommandsDisplay Current Settings Store Dialing Command\Jn Data Buffer Control \Bn Transmit Break\Kn Break Control \Qn Flow Control Selection \Nn Error Correction Mode Selection\Tn Inactivity Timer \V n Protocol Result CodeView Numbers in Blacklist Adaptive Answer Result Code EnableData Calling Tone 42bis Compression ControlCommand +DS44=n V.44 Data Compression Command +DCS=x,y Select V.44 Data CompressionData Compression Reporting Enable Synchronous Buffered Mode SubparametersModulation Selection ModCommand +PCW= n Call Waiting Enable PCM Upstream Ignore Modem on Hold EnableCommand +PMHR=n Modem on Hold Initiate Modem Hook FlashCommand +PMHT=n Modem on Hold Timer Quick Connect Control#Sx Enter Setup Password Command +VCID=n Caller ID SelectionCommand +VDR=x, y Distinctive Ring Report #S=x Store Setup PasswordCommand +++ATCR Escape Sequence Command %%%ATCR Remote Configuration Escape SequenceRegister Unit Range Default Description RegistersValue Speed Value RateBit 56K mode Value Digital lossResult Codes Terse Verbose DescriptionDelayed Remote Configuration Setup Basic ProcedureTo Change the Setup Password To Change the Remote Escape Character Solving Problems Modem Does Not Respond to Commands Modem Cannot Connect When Dialing ModemDisconnects While Online MultiModemZPX User Guide Fax and DataSoftware Can’t Run at the Same Time There Are Garbage Characters on the MonitorModem Doesn’t Work with Caller ID Voice Functions Don’t WorkLoopback Test Voice Mail TestSpeakerphone Test Appendixes Appendix a Regulatory Compliance FCC Part 68 TelecomFCC Part Fax Branding StatementIndustry Canada Canadian Limitations NoticeProtection Against Contact with TNV Circuit EMC, Safety, and R&TTE Directive Compliance New Zealand Telecom Warning NoticeSouth African Notice International Modem RestrictionsAppendix B Technical Specifications Command Buffer Test procedure Local Analog Loopback Test V.54 LoopRemote Digital Loopback Test V.54 Loop Figure C-2. Remote digital loopback testLocal Digital Loopback Test V.54 Loop Figure C-3. Local digital loopback testMultiModemZPX User Guide Loopback Tests Online Warranty Registration Service Limited WarrantyCanadian Customers International Customers outside U.S.A. and Canada International DistributorsTechnical Support Internet SitesUpgrade Overview Identify the Modem FirmwareIdentify the Current Firmware Version Download the Upgrade FileExtract the Upgrade Files Document and Clear Your Stored ParamentersUpgrade the Modem’s Firmware Restore Your ParametersStandard Linux Serial Port Definitions InstallationPC port Linux port Using the Terminal Program Minicom to Verify Operation Using the Modem to Call the InternetCalling the ISP Answering CallsAppendix G Installing Under SCO OpenServer Index MultiModemZPX User Guide Index MultiModemZPX User Guide Index MultiModemZPX User Guide Index

MT5634ZPX-PCI-V92 specifications

The Multi-Tech Systems MT5634ZPX-PCI-V92 is a high-performance V.92 data/fax modem designed to enhance communication capabilities in various applications. This modem is particularly well-suited for commercial and industrial environments where reliable connectivity is crucial.

One of the standout features of the MT5634ZPX-PCI-V92 is its support for the V.92 protocol, which allows for quicker uploads and improved connection speeds compared to earlier standards. It offers download speeds of up to 56 Kbps and upload speeds of up to 48 Kbps, making it an excellent choice for businesses that rely on time-sensitive data transmission. The modem's ability to maintain reliable connections even over noisy telephone lines is a critical aspect of its design, ensuring that users can depend on it for essential communications.

The MT5634ZPX-PCI-V92 also includes advanced error correction and data compression technologies, such as MNP 4 and V.42bis. These technologies work together to ensure data integrity during transfers and to maximize throughput, enabling users to send larger files without compromising quality or speed. Additionally, the modem features a robust fax capability, supporting both analog and digital fax transmissions, which is vital for businesses that frequently deal with document sharing.

A notable characteristic of the MT5634ZPX-PCI-V92 modem is its PCI interface, which allows for easy integration into desktop systems. This plug-and-play capability simplifies installation and setup, making it accessible for users with varying levels of technical expertise. The modem is built on a reliable hardware platform, characterized by its durable components, making it ideal for environments where long-term use is expected.

Moreover, the MT5634ZPX-PCI-V92 comes with comprehensive driver support for various operating systems, including Windows and Linux, ensuring compatibility with a wide range of applications. With its combination of speed, reliability, and ease of use, the Multi-Tech Systems MT5634ZPX-PCI-V92 modem remains a popular option for businesses looking to maintain effective communication channels through dial-up connectivity. Whether for data transmission or faxing, it stands as a solid choice for organizations that require dependable performance in a compact form factor.