Multi-Tech Systems MT2456SMI22 manual Label Content and Format, Label Physical Characteristics

Page 53

Appendix B – Product Approvals, Regulatory Design Considerations, Compliance

8.No repairs are to be made by you. Repairs are to be made only by Multi-Tech Systems or its licensees. Unauthorized repairs void registration and warranty.

9.If your home has specially wired alarm equipment connected to the telephone line, ensure the installation of this equipment does not disable your alarm equipment.

If you have questions about what will disable alarm equipment, consult your telephone company or a qualified installer.

10.Connection to party line service is subject to state tariffs. Contact the state public utility commission, public service commission or corporation commission for information.

11.This equipment is hearing aid compatible.

12.Manufacturing Information:

Manufacturer: Multi-Tech Systems, Inc.

Trade Name

SocketModem

Model Number:

MT2456SMI-22

Registration No:

US: AU7MD04B2456

Ringer Equivalence:

0.4B

Modular Jack (USOC):

RJ11C or RJ11W (single line)

Service Center in USA:

Multi-Tech Systems, Inc.

 

2205 Woodale Drive

 

Mounds View, MN 55112

 

U.S.A.

 

(763) 785-3500

 

(763) 785-9874 Fax

Label Content and Format

Approved terminal equipment and approved protective circuitry shall prominently display the following information using the format shown below:

￿Responsible party

￿Product Identification

￿Equipment Code

￿Ringer Equivalence

￿Ringer Type

￿Indication that the product meets the requirements of 47 CFR Part 68

The information required by the first five items shall correspond to the records in the ACTA database of approved equipment. The required information shall be encoded in the following format:

US: AAAEQ##TXXX

Where:

US: Is a fixed field that indicates the equipment meets all requirements of 47 CFR Part 68 (including the requirements published by ACTA).

AAAis the responsible party’s Grantee Code obtained previously from the FCC’s Common Carrier Bureau or currently from ACTA.

EQ Is an Equipment Code indicating to the Service Provider any special signal handling or billing requirements. The Equipment codes are listed in Annex A (normative).

##Is the Ringer Equivalence Number without a decimal point (e.g. REN of 1.0 = 10, REN of 0.3 = 03). In the case of a “Z” ringer, ZZ shall appear. In the case of approved equipment without a network interface and equipment not connecting to circuits with analog ringing supplied then “NA” shall appear.

T is the ringer type letter associated with the Ringer Equivalence Number, in accordance with the technical requirements. In the case of approved equipment without a network interface and equipment not connecting to circuits with analog ringing supplied, the letter “N” shall appear.

XXXIs a product identifier, unique when combined with the responsible party’s Grantee Code, of at least one and up to nine alphanumeric characters (including one or more dashes (-) if desired. A dash shall not appear as the first or last character nor shall the identifier consist entirely of dashes). The responsible party shall define this identifier.

Label Physical Characteristics

The information required above shall be permanently affixed and legible without magnification. It may be etched, engraved, stamped, indelibly printed or otherwise permanently marked. Alternatively, the required information may be permanently marked on a nameplate of metal, plastic or other material fastened to the enclosure by welding, riveting or with a permanent adhesive. Such a nameplate shall be able to last for the expected lifetime of the equipment and shall not be readily detachable.

Multi-Tech Systems, Inc. MT2456SMI-22 SocketModem Developer’s Guide

53

Image 53
Contents SocketModem Country By Email By Phone PN S000281A, Version aContents Product Description Product Description SpecificationsSpeed Conversion Technical SpecificationsMaximum Component Height Physical DimensionsPin Descriptions Pin Configurations3V DC Power 3V and 5V Serial SocketModem Handling PrecautionsInput High Input Low Outputs Output High Output LowDTE/DCE Commands Generic Modem Control CommandsCall Control Commands Modulation Control CommandsSynchronous Access Mode Commands Error Control and Data Compression CommandsFast Connect Command Line Side Device CommandsSoft Reset and Restore Profile 22bis Generic Modem Control CommandsOperating Mode +VCID Caller ID CIDIdentification +GCI Country of InstallationProcedure Restore Factory Configuration ProfileLocal Analog Loopback Test Load to Internal RAMCommand Echo 22bis DTE/DCE-Modem Interface commandsQuiet Result Codes Control Result Code FormExtended Result Codes Connect Ring No Carrier Error No Dial Tone Busy No AnswerRlsd Option Short Form Long Form Value in ATXn CommandResult Codes OK 0 or DTR Option+IFC DTE-Modem Local Flow Control RTS/CTS Option\G Modem-to-Modem Flow Control XON/XOFF EM Shielding Data +IBC In Band CommandsEntering and Exiting In Band Active State Band Processing of AT Commands Command Hex Codes Description Supported DTE-to-DCE CommandsSupported DCE-to-DTE Commands Dial Modifiers 22bis Call Control CommandsDial Result Code Set Pulse Dial Default Set Tone Dial DefaultReturn to On-Line Data Mode Speaker VolumeMSpeaker Control Display Current Configuration and Stored ProfilesSelect Guard Tone Select Pulse Dial Make/Break RatioReport Line Signal Level \V Single Line Connect Message EnableReport Line Signal Quality Display Blacklisted NumbersNO. Phone Number -DELAY Display Delayed NumbersBehavior in Data Mode Syntax *D Example+VDR Distinctive Ring +PCW Call Waiting EnableReporting Selected Values Table of +MS Command Supported Rates 22bis Modulation Control Commands+MS Modulation Selection SyntaxITU-T or Bell Enable/Disable Line Quality Monitor and Auto-Retrain+ESR Selective Repeat 22bis Error Control and Data Compression Commands+ETBM Call Termination Buffer Management \B Transmit Break to RemoteBreak Control Result Codes OK 0 to 5 Error Otherwise+ESA Configure Synchronous Access Submode 22bis Synchronous Access Mode CommandsReporting Selected Options +ESA?+ITF? Transmit Flow Control ThresholdsSyntax $Fn Defined Values 22bis FastConnect Command$F Fast Connect Control Threshold Adjustments for Telephony Extension 22bis Line Side Device CommandsTRV Tip and Ring Voltage Measurement ResponseRead/Write S-Parameter 22bis S-ParametersAscii Summary of S-Parameter DefaultsRegister Function Range/Units Default S1 Ring Counter S0 Number of Rings to Auto-AnswerS2 Escape Character S3 Carriage Return CharacterS10 Lost Carrier To Hang Up Delay S8 Pause Time For Dial DelayS12 Escape Prompt Delay EPD S9 Carrier Detect Response TimeS19 Reserved S16 Test Mode Bit Mapped Options StatusS20 Reserved S21 V.24/General Bit Mapped Options StatusS25 Delay To DTR Off S24 Sleep Inactivity TimerS26 RTS to CTS Delay S22 Speaker/Results Bit Mapped Options StatusS27 Bit Mapped Options Status S30 Disconnect Inactivity TimerS28 Bit Mapped Options Status S29 Flash Dial Modifier TimeS36 Lapm Failure Control S38 Delay Before Forced Hang UpS37 Desired Line Connection Speed S39 Flow Control Bit Mapped Options StatusS48 V.42 Negotiation Action S41 General Bit Mapped Options StatusS82 Break Handling Options S86 Call Failure Reason CodeS95 Extended Result Codes Control S91 Pstn Transmit Attenuation LevelTable of Result Code Definitions 22bis Result CodesCode Message Meaning Connect75TX/1200RX Is enabled Figure A-1. Serial Test/Demo Board Block Diagram Block DiagramCountry Certifications Product Safety and EMC ApprovalsCountry Country Code More plannedHardware Considerations Regulatory Design ConsiderationsSafety Qty Name Description SocketModem PlacementTelecom Requirements for the United States ComplianceMulti-Tech Systems, Inc. Compliance Label Physical Characteristics Label Content and FormatOther Label Requirements Telecommunications Regulations for CanadaLabeling Continuity and Changes Industry Canada New Zealand Telecom Warning NoticeSouth African Statement EMC, Safety, and R&TTE Directive ComplianceInternational Modem Restrictions Index Index