Multi-Tech Systems MT2456SMI22 manual S0 Number of Rings to Auto-Answer, S1 Ring Counter

Page 37

Chapter 4 - V.22bis Commands

S-PARAMETER DEFINITIONS

S0 - Number of Rings to Auto-Answer

S0 sets the number of the rings required before the modem automatically answers a call. Setting this parameter to zero disables auto-answer mode.

Range: 0-255 rings

Default: 0

S1 - Ring Counter

S1 is incremented each time the modem detects a ring signal on the telephone line. S1 is cleared if no rings occur over an eight second interval.

Range: 0-255 rings

Default: 0

S2 - Escape Character

S2 holds the decimal value of the ASCII character used as the escape character. The default value corresponds to an ASCII '+'. A value over 127 disables the escape process, i.e., no escape character will be recognized.

Range: 0-255, ASCII decimal

Default: 43 (+)

S3 - Carriage Return Character

S3 sets the command line and result code terminator character. Pertains to asynchronous operation only. Range: 0-127, ASCII decimal

Default: 13 (Carriage Return)

S4 - Line Feed Character

S4 sets the character recognized as a line feed. Pertains to asynchronous operation only. The Line Feed control character is output after the Carriage Return control character if verbose result codes are used.

Range: 0-127, ASCII decimal

Default: 10 (Line Feed)

S5 - Backspace Character

S5 sets the character recognized as a backspace. Pertains to asynchronous operation only. The modem will not recognize the Backspace character if it is set to a value that is greater than 32 ASCII. This character can be used to edit a command line. When the echo command is enabled, the modem echoes back to the local DTE the Backspace character, an ASCII space character and a second Backspace character; this means a total of three characters are transmitted each time the modem processes the Backspace character.

Range: 0-32, ASCII decimal

Default: 8 (Backspace)

S6 - Wait Time before Blind Dialing or for Dial Tone

S6 operation is country dependent.

1.Sets the length of time, in seconds, that the modem will wait before starting to dial after going off-hook when blind dialing. This operation, however, may be affected by some ATX options according to country restrictions. The “Wait for Dial Tone” call progress feature (W dial modifier in the dial string) will override the value in register S6. (U.S.)

2.Sets the length of time, in seconds, that the modem will wait for dial tone when encountering a “W” dial modifier

before returning NO DIAL TONE result code. (Other countries.)

The modem always pauses for a minimum of 2 seconds, even if the value of S6 is less than 2 seconds. Range: 2-255 seconds

Default: 2

S7 - Wait Time for Carrier, Silence, or Dial Tone

S7 operation is country dependent.

1.Sets the length of time, in seconds, that the modem will wait for carrier before hanging up. The timer is started when the modem finishes dialing (originate), or 2 seconds after going off-hook (answer). In originate mode, the timer is reset upon detection of answer tone if allowed by country restrictions.

2.Sets the length of time, in seconds, that modem will wait for silence when encountering the @ dial modifier before continuing with the next dial string parameter.

3.Sets the length of time, in seconds, that the modem will wait for dial tone when encountering a “W” dial modifier

before continuing with the next dial string parameter. (U.S.) Range: 1-255 seconds

Default: 50

Multi-Tech Systems, Inc. MT2456SMI-22 SocketModem Developer’s Guide

37

Image 37
Contents SocketModem Country By Email By Phone PN S000281A, Version aContents Product Description Product Description SpecificationsSpeed Conversion Technical SpecificationsMaximum Component Height Physical DimensionsPin Descriptions Pin Configurations3V DC Power 3V and 5V Serial SocketModem Handling PrecautionsInput High Input Low Outputs Output High Output LowDTE/DCE Commands Generic Modem Control CommandsCall Control Commands Modulation Control CommandsSynchronous Access Mode Commands Error Control and Data Compression CommandsFast Connect Command Line Side Device CommandsSoft Reset and Restore Profile 22bis Generic Modem Control CommandsOperating Mode +VCID Caller ID CIDIdentification +GCI Country of InstallationProcedure Restore Factory Configuration ProfileLocal Analog Loopback Test Load to Internal RAMCommand Echo 22bis DTE/DCE-Modem Interface commandsQuiet Result Codes Control Result Code FormExtended Result Codes Connect Ring No Carrier Error No Dial Tone Busy No AnswerRlsd Option Short Form Long Form Value in ATXn CommandResult Codes OK 0 or DTR Option\G Modem-to-Modem Flow Control XON/XOFF RTS/CTS Option+IFC DTE-Modem Local Flow Control Entering and Exiting In Band Active State +IBC In Band CommandsEM Shielding Data Supported DCE-to-DTE Commands Command Hex Codes Description Supported DTE-to-DCE CommandsBand Processing of AT Commands Dial 22bis Call Control CommandsDial Modifiers Result Code Set Pulse Dial Default Set Tone Dial DefaultReturn to On-Line Data Mode Speaker VolumeMSpeaker Control Display Current Configuration and Stored ProfilesSelect Guard Tone Select Pulse Dial Make/Break RatioReport Line Signal Level \V Single Line Connect Message EnableReport Line Signal Quality Display Blacklisted NumbersNO. Phone Number -DELAY Display Delayed NumbersBehavior in Data Mode Syntax *D ExampleReporting Selected Values +PCW Call Waiting Enable+VDR Distinctive Ring Table of +MS Command Supported Rates 22bis Modulation Control Commands+MS Modulation Selection SyntaxITU-T or Bell Enable/Disable Line Quality Monitor and Auto-Retrain+ESR Selective Repeat 22bis Error Control and Data Compression Commands+ETBM Call Termination Buffer Management \B Transmit Break to RemoteBreak Control Result Codes OK 0 to 5 Error Otherwise+ESA Configure Synchronous Access Submode 22bis Synchronous Access Mode CommandsReporting Selected Options +ESA?+ITF? Transmit Flow Control Thresholds$F Fast Connect Control 22bis FastConnect CommandSyntax $Fn Defined Values Threshold Adjustments for Telephony Extension 22bis Line Side Device CommandsTRV Tip and Ring Voltage Measurement ResponseRead/Write S-Parameter 22bis S-ParametersRegister Function Range/Units Default Summary of S-Parameter DefaultsAscii S1 Ring Counter S0 Number of Rings to Auto-AnswerS2 Escape Character S3 Carriage Return CharacterS10 Lost Carrier To Hang Up Delay S8 Pause Time For Dial DelayS12 Escape Prompt Delay EPD S9 Carrier Detect Response TimeS19 Reserved S16 Test Mode Bit Mapped Options StatusS20 Reserved S21 V.24/General Bit Mapped Options StatusS25 Delay To DTR Off S24 Sleep Inactivity TimerS26 RTS to CTS Delay S22 Speaker/Results Bit Mapped Options StatusS27 Bit Mapped Options Status S30 Disconnect Inactivity TimerS28 Bit Mapped Options Status S29 Flash Dial Modifier TimeS36 Lapm Failure Control S38 Delay Before Forced Hang UpS37 Desired Line Connection Speed S39 Flow Control Bit Mapped Options StatusS48 V.42 Negotiation Action S41 General Bit Mapped Options StatusS82 Break Handling Options S86 Call Failure Reason CodeS95 Extended Result Codes Control S91 Pstn Transmit Attenuation LevelTable of Result Code Definitions 22bis Result CodesCode Message Meaning Connect75TX/1200RX Is enabled Figure A-1. Serial Test/Demo Board Block Diagram Block DiagramCountry Certifications Product Safety and EMC ApprovalsCountry Country Code More plannedHardware Considerations Regulatory Design ConsiderationsSafety Qty Name Description SocketModem PlacementMulti-Tech Systems, Inc. Compliance ComplianceTelecom Requirements for the United States Label Physical Characteristics Label Content and FormatLabeling Continuity and Changes Telecommunications Regulations for CanadaOther Label Requirements Industry Canada New Zealand Telecom Warning NoticeInternational Modem Restrictions EMC, Safety, and R&TTE Directive ComplianceSouth African Statement Index Index