Multi-Tech Systems MT2456SMI22 manual Extended Result Codes

Page 16

Chapter 4 - V.22bis Commands

X Extended Result Codes

This command selects the subset of the result code messages used by the modem to inform the DTE of the results of commands. Blind dialing is enabled or disabled by country parameters. If the user wishes to enforce dial tone detection, a "W" can be placed in the dial string (see D command). The information below is based upon the default implementation of the X results table.

Syntax X<value>

Defined Values

<value> Decimal number corresponding to the selected option.

0Disables reporting of busy tones unless forced otherwise by country requirements; send only OK, CONNECT, RING, NO CARRIER, ERROR, and NO ANSWER result codes. Blind dialing is enabled/disabled by country parameters. If busy tone detection is enforced and busy tone is detected, NO CARRIER will be reported. If dial tone detection is enforced or selected and dial tone is not detected, NO CARRIER will be reported instead of NO DIAL TONE. The value 000b is written to S22 bits 6, 5, and 4, respectively.

1Disables reporting of busy tones unless forced otherwise by country requirements; send only OK, CONNECT, RING, NO CARRIER, ERROR, NO ANSWER, and CONNECT XXXX (XXXX = rate). Blind dialing enabled/disabled by country parameters. If busy tone detection is enforced and busy tone is detected, NO CARRIER will be reported instead of BUSY. If dial tone detection is enforced or selected and dial tone is not detected, NO CARRIER will be reported instead of NO DIAL TONE. The value 100b is written to S22 bits 6, 5, and 4, respectively.

2Disables reporting of busy tones unless forced otherwise by country requirements; send only OK, CONNECT, RING, NO CARRIER, ERROR, NO DIAL TONE, NO ANSWER, and CONNECT XXXX. If busy tone detection is enforced and busy tone is detected, NO CARRIER will be reported instead of BUSY. If dial tone detection is enforced or selected and dial tone is not detected, NO DIAL TONE will be reported instead of NO CARRIER. The value 101b is written to S22 bits 6, 5, and 4, respectively.

3Enables reporting of busy tones; send only OK, CONNECT, RING, NO CARRIER, ERROR, NO ANSWER, and CONNECT XXXX. Blind dialing is enabled/disabled by country parameters. If dial tone detection is enforced and dial tone is not detected, NO CARRIER will be reported. The value 110b is written to S22 bits 6, 5, and 4, respectively.

4Enables reporting of busy tones; send all messages. The value 111b is written to S22 bits 6, 5, and 4,

respectively. (Default)

Result Codes OK <value> = 0 to 4 ERROR Otherwise

Table of Result Codes

Short Form

Long Form

 

n Value in ATXn Command

 

0

1

2

3

4

 

 

0

OK

X

X

X

X

X

1

CONNECT

X

X

X

X

X

2

RING

X

X

X

X

X

3

NO CARRIER

X

X

X

X

X

4

ERROR

X

X

X

X

X

5

CONNECT 1200

1

X

X

X

X

6

NO DIAL TONE

3

3

X

X

X

7

BUSY

3

3

3

X

X

8

NO ANSWER

X

X

X

X

X

9

CONNECT 600

1

X

X

X

X

10

CONNECT 2400

1

X

X

X

X

11

CONNECT 4800

1

X

X

X

X

12

CONNECT 9600

1

X

X

X

X

13

CONNECT 7200

1

X

X

X

X

14

CONNECT 12000

1

X

X

X

X

15

CONNECT 14400

1

X

X

X

X

16

CONNECT 19200

1

X

X

X

X

17

CONNECT 38400

1

X

X

X

X

18

CONNECT 57600

1

X

X

X

X

19

CONNECT 115200

1

X

X

X

X

22

CONNECT 75TX/1200RX

1

X

X

X

X

23

CONNECT 1200TX/75RX

1

X

X

X

X

24

DELAYED

4

4

4

4

X

32

BLACKLISTED

4

4

4

4

X

40

CARRIER 300

X

X

X

X

X

41

CARRIER 1200/75

X

X

X

X

X

Multi-Tech Systems, Inc. MT2456SMI-22 SocketModem Developer’s Guide

16

Image 16
Contents SocketModem PN S000281A, Version a Country By Email By PhoneContents Product Description Specifications Product DescriptionTechnical Specifications Speed ConversionPhysical Dimensions Maximum Component HeightPin Configurations Pin Descriptions3V DC Power Handling Precautions 3V and 5V Serial SocketModemInput High Input Low Outputs Output High Output LowGeneric Modem Control Commands DTE/DCE CommandsCall Control Commands Modulation Control CommandsError Control and Data Compression Commands Synchronous Access Mode CommandsFast Connect Command Line Side Device Commands22bis Generic Modem Control Commands Soft Reset and Restore ProfileOperating Mode +VCID Caller ID CID+GCI Country of Installation IdentificationRestore Factory Configuration Profile ProcedureLocal Analog Loopback Test Load to Internal RAM22bis DTE/DCE-Modem Interface commands Command EchoQuiet Result Codes Control Result Code FormConnect Ring No Carrier Error No Dial Tone Busy No Answer Extended Result CodesShort Form Long Form Value in ATXn Command Rlsd OptionResult Codes OK 0 or DTR Option\G Modem-to-Modem Flow Control XON/XOFF RTS/CTS Option+IFC DTE-Modem Local Flow Control Entering and Exiting In Band Active State +IBC In Band CommandsEM Shielding Data Supported DCE-to-DTE Commands Command Hex Codes Description Supported DTE-to-DCE CommandsBand Processing of AT Commands Dial 22bis Call Control CommandsDial Modifiers Set Tone Dial Default Result Code Set Pulse Dial DefaultReturn to On-Line Data Mode Speaker VolumeDisplay Current Configuration and Stored Profiles MSpeaker ControlSelect Guard Tone Select Pulse Dial Make/Break Ratio\V Single Line Connect Message Enable Report Line Signal LevelReport Line Signal Quality Display Blacklisted NumbersDisplay Delayed Numbers NO. Phone Number -DELAYBehavior in Data Mode Syntax *D ExampleReporting Selected Values +PCW Call Waiting Enable+VDR Distinctive Ring 22bis Modulation Control Commands Table of +MS Command Supported Rates+MS Modulation Selection SyntaxEnable/Disable Line Quality Monitor and Auto-Retrain ITU-T or Bell22bis Error Control and Data Compression Commands +ESR Selective Repeat+ETBM Call Termination Buffer Management \B Transmit Break to RemoteResult Codes OK 0 to 5 Error Otherwise Break Control22bis Synchronous Access Mode Commands +ESA Configure Synchronous Access SubmodeReporting Selected Options +ESA?Transmit Flow Control Thresholds +ITF?$F Fast Connect Control 22bis FastConnect CommandSyntax $Fn Defined Values 22bis Line Side Device Commands Threshold Adjustments for Telephony ExtensionTRV Tip and Ring Voltage Measurement Response22bis S-Parameters Read/Write S-ParameterRegister Function Range/Units Default Summary of S-Parameter DefaultsAscii S0 Number of Rings to Auto-Answer S1 Ring CounterS2 Escape Character S3 Carriage Return CharacterS8 Pause Time For Dial Delay S10 Lost Carrier To Hang Up DelayS12 Escape Prompt Delay EPD S9 Carrier Detect Response TimeS16 Test Mode Bit Mapped Options Status S19 ReservedS20 Reserved S21 V.24/General Bit Mapped Options StatusS24 Sleep Inactivity Timer S25 Delay To DTR OffS26 RTS to CTS Delay S22 Speaker/Results Bit Mapped Options StatusS30 Disconnect Inactivity Timer S27 Bit Mapped Options StatusS28 Bit Mapped Options Status S29 Flash Dial Modifier TimeS38 Delay Before Forced Hang Up S36 Lapm Failure ControlS37 Desired Line Connection Speed S39 Flow Control Bit Mapped Options StatusS41 General Bit Mapped Options Status S48 V.42 Negotiation ActionS82 Break Handling Options S86 Call Failure Reason CodeS91 Pstn Transmit Attenuation Level S95 Extended Result Codes Control22bis Result Codes Table of Result Code DefinitionsCode Message Meaning Connect75TX/1200RX Is enabled Block Diagram Figure A-1. Serial Test/Demo Board Block DiagramProduct Safety and EMC Approvals Country CertificationsCountry Country Code More plannedRegulatory Design Considerations Hardware ConsiderationsSafety SocketModem Placement Qty Name DescriptionMulti-Tech Systems, Inc. Compliance ComplianceTelecom Requirements for the United States Label Content and Format Label Physical CharacteristicsLabeling Continuity and Changes Telecommunications Regulations for CanadaOther Label Requirements New Zealand Telecom Warning Notice Industry CanadaInternational Modem Restrictions EMC, Safety, and R&TTE Directive ComplianceSouth African Statement Index Index