Appendix B – Product Approvals, Regulatory Design Considerations, Compliance

7.Some parameters required for compliance with Telecom’s Telepermit requirements are dependent on the equipment (PC) associated with this device. The associated equipment shall be set to operate within the following limits for compliance with Telecom’s Specifications:

For repeat calls to the same number:

￿There shall be no more than 10 call attempts to the same number within any 30 minute period for any single manual call initiation, and

￿The equipment shall go on-hook for a period of not less than 30 seconds between the end of one

attempt and the beginning of the next attempt. For automatic calls to different numbers:

￿The equipment shall be set to ensure that automatic calls to different numbers are spaced such that there is no less than 5 seconds between the end of one call attempt and the beginning of another.

8.For correct operation, total of the RN’s of all devices connected to a single line at any time should not exceed 5.

International Modem Restrictions

Some dialing and answering defaults and restrictions may vary for international modems. Changing settings may cause a modem to become non-compliant with national telecom requirements in specific countries. Also note that some software packages may have features or lack restrictions that may cause the modem to become non- compliant.

EMC, Safety, and R&TTE Directive Compliance

The CE mark is affixed to this product to confirm compliance with the following European Community Directives: Council Directive 89/336/EEC of 3 May 1989 on the approximation of the laws of Member States relating to electromagnetic compatibility;

and

Council Directive 73/23/EEC of 19 February 1973 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits;

and

Council Directive 1999/5/EC of 9 March on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity.

South African Statement

This modem must be used in conjunction with an approved surge protection device.

Multi-Tech Systems, Inc. MT2456SMI-22 SocketModem Developer’s Guide

56

Image 56
Contents SocketModem PN S000281A, Version a Country By Email By PhoneContents Product Description Specifications Product DescriptionTechnical Specifications Speed ConversionPhysical Dimensions Maximum Component HeightPin Configurations Pin Descriptions3V DC Power Handling Precautions 3V and 5V Serial SocketModemInput High Input Low Outputs Output High Output LowGeneric Modem Control Commands DTE/DCE CommandsCall Control Commands Modulation Control CommandsError Control and Data Compression Commands Synchronous Access Mode CommandsFast Connect Command Line Side Device Commands22bis Generic Modem Control Commands Soft Reset and Restore ProfileOperating Mode +VCID Caller ID CID+GCI Country of Installation IdentificationRestore Factory Configuration Profile ProcedureLocal Analog Loopback Test Load to Internal RAM22bis DTE/DCE-Modem Interface commands Command EchoQuiet Result Codes Control Result Code FormConnect Ring No Carrier Error No Dial Tone Busy No Answer Extended Result CodesShort Form Long Form Value in ATXn Command Rlsd OptionResult Codes OK 0 or DTR Option+IFC DTE-Modem Local Flow Control RTS/CTS Option\G Modem-to-Modem Flow Control XON/XOFF EM Shielding Data +IBC In Band CommandsEntering and Exiting In Band Active State Band Processing of AT Commands Command Hex Codes Description Supported DTE-to-DCE CommandsSupported DCE-to-DTE Commands Dial Modifiers 22bis Call Control CommandsDial Set Tone Dial Default Result Code Set Pulse Dial DefaultReturn to On-Line Data Mode Speaker VolumeDisplay Current Configuration and Stored Profiles MSpeaker ControlSelect Guard Tone Select Pulse Dial Make/Break Ratio\V Single Line Connect Message Enable Report Line Signal LevelReport Line Signal Quality Display Blacklisted NumbersDisplay Delayed Numbers NO. Phone Number -DELAYBehavior in Data Mode Syntax *D Example+VDR Distinctive Ring +PCW Call Waiting EnableReporting Selected Values 22bis Modulation Control Commands Table of +MS Command Supported Rates+MS Modulation Selection SyntaxEnable/Disable Line Quality Monitor and Auto-Retrain ITU-T or Bell22bis Error Control and Data Compression Commands +ESR Selective Repeat+ETBM Call Termination Buffer Management \B Transmit Break to RemoteResult Codes OK 0 to 5 Error Otherwise Break Control22bis Synchronous Access Mode Commands +ESA Configure Synchronous Access SubmodeReporting Selected Options +ESA?Transmit Flow Control Thresholds +ITF?Syntax $Fn Defined Values 22bis FastConnect Command$F Fast Connect Control 22bis Line Side Device Commands Threshold Adjustments for Telephony ExtensionTRV Tip and Ring Voltage Measurement Response22bis S-Parameters Read/Write S-ParameterAscii Summary of S-Parameter DefaultsRegister Function Range/Units Default S0 Number of Rings to Auto-Answer S1 Ring CounterS2 Escape Character S3 Carriage Return CharacterS8 Pause Time For Dial Delay S10 Lost Carrier To Hang Up DelayS12 Escape Prompt Delay EPD S9 Carrier Detect Response TimeS16 Test Mode Bit Mapped Options Status S19 ReservedS20 Reserved S21 V.24/General Bit Mapped Options StatusS24 Sleep Inactivity Timer S25 Delay To DTR OffS26 RTS to CTS Delay S22 Speaker/Results Bit Mapped Options StatusS30 Disconnect Inactivity Timer S27 Bit Mapped Options StatusS28 Bit Mapped Options Status S29 Flash Dial Modifier TimeS38 Delay Before Forced Hang Up S36 Lapm Failure ControlS37 Desired Line Connection Speed S39 Flow Control Bit Mapped Options StatusS41 General Bit Mapped Options Status S48 V.42 Negotiation ActionS82 Break Handling Options S86 Call Failure Reason CodeS91 Pstn Transmit Attenuation Level S95 Extended Result Codes Control22bis Result Codes Table of Result Code DefinitionsCode Message Meaning Connect75TX/1200RX Is enabled Block Diagram Figure A-1. Serial Test/Demo Board Block DiagramProduct Safety and EMC Approvals Country CertificationsCountry Country Code More plannedRegulatory Design Considerations Hardware ConsiderationsSafety SocketModem Placement Qty Name DescriptionTelecom Requirements for the United States ComplianceMulti-Tech Systems, Inc. Compliance Label Content and Format Label Physical CharacteristicsOther Label Requirements Telecommunications Regulations for CanadaLabeling Continuity and Changes New Zealand Telecom Warning Notice Industry CanadaSouth African Statement EMC, Safety, and R&TTE Directive ComplianceInternational Modem Restrictions Index Index