Multi-Tech Systems MT2456SMI22 Set Tone Dial Default, Result Code Set Pulse Dial Default, Answer

Page 22
OK <value> = 0 to 3 ERROR Otherwise

Chapter 4 - V.22bis Commands

T Set Tone Dial Default

This command forces DTMF dialing until the next P dial modifier or P command is received. The modem will set an S-Parameter bit to indicate that all subsequent dialing should be conducted in tone mode. The DP command will override this command. Clears S14 bit 5. This command may not be permitted in some countries. (See P.)

Result Code

OK

P

Set Pulse Dial Default

This command forces pulse dialing until the next T dial modifier or T command is received. Sets S14 bit 5.

As soon as a dial command is executed which explicitly specifies the dialing mod e for that particular call (e.g.; ATDT), this command is overridden so that all future dialing will be tone dialed. (See T command.)

This command may not be permitted in some countries.

Result Code OK

A Answer

The modem will go off-hook and attempt to answer an incoming call if correct conditions are met. Upon successful completion of answer handshake, the modem will go on-line in answer mode. This command may be affected by the state of Line Current Sense, if enabled. (Most countries do not require Line Current Sense.) Operation is also dependent upon country-specific requirements.

The modem will enter the connect state after exchanging carrier with the remote modem. If no carrier is detected within a period specified in register S7, the modem hangs up. Any character entered during the connect sequence will abort the connection attempt.

H Disconnect (Hang-Up)

This command initiates a hang up sequence. It may not be available for some countries due to PTT restrictions. Syntax H<value>

Defined Values

<value> Decimal number corresponding to the selected option.

0The modem will release the line if the modem is currently on-line, and will terminate any test (AT&T) that is in progress. Country specific, modulation specific, and error correction protocol specific (S38) processing is handled outside of the H0 command.

1If on-hook, the modem will go off-hook and enter command mode. For U.S., the modem will remain off-hook. For

other countries, the modem will return on-hook after a period of time determined by S7. Result Codes OK <value> = 0 or 1.

ERROR Otherwise.

O Return to On-Line Data Mode

This command determines how the modem will enter the on-line data mode. If in the online command mode, the modem enters the on-line data mode with or without a retrain. If in the off-line command mode (no connection), the modem reports ERROR.

Syntax O<value>

Defined Values

<value> Decimal number corresponding to the selected option.

0Enters on-line data mode without a retrain. Handling is determined by the Call Establishment task. Generally, if a connection exists, this command connects the DTE back to the remote modem after an escape (+++).

1Enters on-line data mode with a retrain before returning to on-line data mode.

Result Codes OK <value> = 0 to 1 and a connection exists

ERROR Otherwise, or if not connected

L Speaker Volume

This command sets the speaker volume control. The parameter value, if valid, is written to S22 bits 0 and 1. Syntax L<value>

Defined Values

<value> Decimal number corresponding to the selected option.

0Low volume.

1Low volume. (Default)

2Medium volume.

3High volume.

Result Codes

Multi-Tech Systems, Inc. MT2456SMI-22 SocketModem Developer’s Guide

22

Image 22
Contents SocketModem PN S000281A, Version a Country By Email By PhoneContents Product Description Specifications Product DescriptionTechnical Specifications Speed ConversionPhysical Dimensions Maximum Component HeightPin Configurations Pin Descriptions3V DC Power Input High Input Low Handling Precautions3V and 5V Serial SocketModem Outputs Output High Output LowCall Control Commands Generic Modem Control CommandsDTE/DCE Commands Modulation Control CommandsFast Connect Command Error Control and Data Compression CommandsSynchronous Access Mode Commands Line Side Device CommandsOperating Mode 22bis Generic Modem Control CommandsSoft Reset and Restore Profile +VCID Caller ID CID+GCI Country of Installation IdentificationLocal Analog Loopback Test Restore Factory Configuration ProfileProcedure Load to Internal RAMQuiet Result Codes Control 22bis DTE/DCE-Modem Interface commandsCommand Echo Result Code FormConnect Ring No Carrier Error No Dial Tone Busy No Answer Extended Result CodesResult Codes OK 0 or Short Form Long Form Value in ATXn CommandRlsd Option DTR Option\G Modem-to-Modem Flow Control XON/XOFF RTS/CTS Option+IFC DTE-Modem Local Flow Control Entering and Exiting In Band Active State +IBC In Band CommandsEM Shielding Data Supported DCE-to-DTE Commands Command Hex Codes Description Supported DTE-to-DCE CommandsBand Processing of AT Commands Dial 22bis Call Control CommandsDial Modifiers Return to On-Line Data Mode Set Tone Dial DefaultResult Code Set Pulse Dial Default Speaker VolumeSelect Guard Tone Display Current Configuration and Stored ProfilesMSpeaker Control Select Pulse Dial Make/Break RatioReport Line Signal Quality \V Single Line Connect Message EnableReport Line Signal Level Display Blacklisted NumbersBehavior in Data Mode Display Delayed NumbersNO. Phone Number -DELAY Syntax *D ExampleReporting Selected Values +PCW Call Waiting Enable+VDR Distinctive Ring +MS Modulation Selection 22bis Modulation Control CommandsTable of +MS Command Supported Rates SyntaxEnable/Disable Line Quality Monitor and Auto-Retrain ITU-T or Bell+ETBM Call Termination Buffer Management 22bis Error Control and Data Compression Commands+ESR Selective Repeat \B Transmit Break to RemoteResult Codes OK 0 to 5 Error Otherwise Break ControlReporting Selected Options 22bis Synchronous Access Mode Commands+ESA Configure Synchronous Access Submode +ESA?Transmit Flow Control Thresholds +ITF?$F Fast Connect Control 22bis FastConnect CommandSyntax $Fn Defined Values TRV Tip and Ring Voltage Measurement 22bis Line Side Device CommandsThreshold Adjustments for Telephony Extension Response22bis S-Parameters Read/Write S-ParameterRegister Function Range/Units Default Summary of S-Parameter DefaultsAscii S2 Escape Character S0 Number of Rings to Auto-AnswerS1 Ring Counter S3 Carriage Return CharacterS12 Escape Prompt Delay EPD S8 Pause Time For Dial DelayS10 Lost Carrier To Hang Up Delay S9 Carrier Detect Response TimeS20 Reserved S16 Test Mode Bit Mapped Options StatusS19 Reserved S21 V.24/General Bit Mapped Options StatusS26 RTS to CTS Delay S24 Sleep Inactivity TimerS25 Delay To DTR Off S22 Speaker/Results Bit Mapped Options StatusS28 Bit Mapped Options Status S30 Disconnect Inactivity TimerS27 Bit Mapped Options Status S29 Flash Dial Modifier TimeS37 Desired Line Connection Speed S38 Delay Before Forced Hang UpS36 Lapm Failure Control S39 Flow Control Bit Mapped Options StatusS82 Break Handling Options S41 General Bit Mapped Options StatusS48 V.42 Negotiation Action S86 Call Failure Reason CodeS91 Pstn Transmit Attenuation Level S95 Extended Result Codes ControlCode Message Meaning 22bis Result CodesTable of Result Code Definitions Connect75TX/1200RX Is enabled Block Diagram Figure A-1. Serial Test/Demo Board Block DiagramCountry Country Code Product Safety and EMC ApprovalsCountry Certifications More plannedRegulatory Design Considerations Hardware ConsiderationsSafety SocketModem Placement Qty Name DescriptionMulti-Tech Systems, Inc. Compliance ComplianceTelecom Requirements for the United States Label Content and Format Label Physical CharacteristicsLabeling Continuity and Changes Telecommunications Regulations for CanadaOther Label Requirements New Zealand Telecom Warning Notice Industry CanadaInternational Modem Restrictions EMC, Safety, and R&TTE Directive ComplianceSouth African Statement Index Index