MGE UPS Systems 66846, 66244, 66074 user manual 34/69

Page 34

www.mgeups.com

Network

Management Cards

User Manual

ZEnvironment log interval: [from 5 to 99999 sec ]. Temperature and humidity measurement save period. Default value = 300 sec. (only visible if the sensor is present).

ZEnvironment refresh rate: [from 5 to 99999 sec]. “Environment status” page refresh rate. Default value = 60 sec. (only visible if the sensor is present).

ZEnvironment input grace period : [from 0 to 9 sec ]. Period during which a status change by one of the inputs is not considered. Default value = 1 sec. (only visible if the sensor is present).

Z“Reset communication” button: performs a remote reboot of the card without modifying the configuration. This action is compulsory for consideration of any changes made on the “Network settingspage. Security of this operation is ensured by requesting Login and Password.

Z“Fatory Reset” button: enables restoration of the default configuration of all the card’s parameters. The TCP/IP parameters: IP address, subnet mask, gateway and BootP/DHCP value are maintained if the “Keep TCP/IP parameters” option is selected. Security of this operation is ensured by requesting Login and Password. Default login and Password are: MGEUPS

Note:

If any of these parameters are changed, the card must be rebooted.

T H E U N I N T E R R U P T I B L E P O W E R P R O V I D E R

Network Management Card – User Manual

34003676EN/GA

Page 34/69

Image 34
Contents E U N I N T E R R U P T I B L E P O W E R P R O V I D E R Table of Contents Network Management CardsMaintenance Software UPGRADE62 ConfigurationConfiguration VIA Telnet Configuration VIA SSH APPENDICES63 Tables of Alarms and EventsIntroduction MGE Network SolutionConnecting the UPS to the Network Network Management Card or ProxyMonitoring the UPSs over the network MGE supervisor Enterprise Power ManagerProtecting the computers / servers Network Shutdown moduleSetting up the protection Presentation of the Environment Sensor solutionHow to connect UPS / agent / network ConnectionDirect sending of E-mail Compatibility with the legacy Solution-Pac WAN offeringSending text messages SMS Technical data 9/69 Basic configuration Installation and ConfigurationInstallation Environment SensorSupervision / Administration via a Web browser Optimising the performance of your browserUPS zone general information on the UPS UPSUPS properties UPS status zone essential informationBattery status zone On-line help 3 3-Phase display Normal input measurementsUPS Control Battery measurementsBy Pass measurements 17/69 UPS weekly schedule programming Shutdown parameters Important note20/69 Viewing the alarms Logs Measurements23/69 Event log System log Email Notification NotificationNotified events Mail message configuration see next Recipient ListSender Email Message SettingsSubject 29/69 Configuration User Name and password by default are MgeupsNetwork Settings 32/69 System 34/69 Notified Applications Central Shutdown Configuration Access control 38/69 SSL Time Status Configuration Log CharacteristicsEnvironment Environment status Environment Settings Humidity4 Log Set-up of the shutdown parameters Servers protectionShutdown criteria managed by the Management Card Controlled outlets Specific set-up for long autonomy installation 30 mnShutdown when backup time is less than Shutdown durationLoad shedding or sequential shutdown Sequential startupMain UPS outlet Different server and UPS shutdown sequencesProgrammable outlet 49/69 2.2 Programmable outlet 2.1 Main UPS outlet2.3 Programmable outlet 51/69 3.1 Main UPS outlet 3.2 Programmable outletNetwork 4 Off/On command Main outlet55/69 Configuration in local mode and via Telnet or SSH Configuring a set of cards with MupgradeConfiguration in local mode Choice 1 Snmp agent configuration menu MgeupsChoice 3 Access control Choice 2 UPS parametersChoice 4 Restore default configuration Choice 5 Reset the cardConfiguration via SSH Configuration via TelnetPuTTY SSH Client Program 61/69 Card firmware upgrade using Mupgrade Windows MaintenanceSoftware upgrade Card software upgrade via Tftp Unix and WindowsAppendices Tables of alarms and eventsAlarm table UPS event tableUPS 65/69 System alarm table English FrenchGlossary Subnet mask Programmable outlet controlled outletTelnet Trap Snmp UM-Client

66074, 66244, 66846 specifications

MGE UPS Systems, a renowned leader in the uninterruptible power supply (UPS) sector, offers a range of products designed to deliver reliable power protection for critical applications. Among their notable models are the MGE UPS Systems 66846, 66244, and 66074, each offering unique features, advanced technologies, and robust characteristics tailored for various operational needs.

The MGE UPS Systems 66846 is characterized by its high efficiency and modular design, making it suitable for a wide array of environments. This model incorporates advanced power management capabilities, which ensures that users benefit from enhanced energy savings while maintaining optimal performance. With a scalable architecture, the 66846 can adapt to evolving power requirements, providing users with the flexibility to expand their system as their needs grow. The model also includes intelligent battery management features that prolong battery life and enhance reliability.

Moving to the MGE UPS Systems 66244, this model stands out for its compact design and high power density. It is engineered to deliver superior electrical performance while occupying minimal space, making it an excellent choice for facilities with limited room for equipment. The 66244's advanced thermal management system ensures that the device operates efficiently under varying load conditions without overheating. Its intuitive user interface simplifies monitoring and managing the UPS, giving users real-time insights into operational status and alerts.

The MGE UPS Systems 66074 offers advanced features geared towards critical infrastructure in data centers and telecom applications. This model boasts high fault tolerance and redundancy mechanisms, ensuring continuous power delivery even in the event of component failure. The 66074 is equipped with cutting-edge digital signal processing technology, which enhances the performance and reliability of the power supply. Additionally, it supports various connectivity options, allowing for seamless integration with existing power management systems.

Across these models, MGE UPS Systems emphasize user-friendliness with intuitive control interfaces and remote monitoring capabilities. Furthermore, their commitment to sustainability is evident in the energy-efficient designs that reduce the overall carbon footprint of power management operations. Each unit is rigorously tested to adhere to international safety and performance standards, ensuring confidence in their reliability for critical applications. Overall, MGE UPS Systems 66846, 66244, and 66074 represent a blend of innovation, efficiency, and dependability in the UPS market, making them ideal choices for businesses looking to safeguard their operations against power interruptions.