1.1.4 Connection

Before installing the MGE Network Solution, the UPS must be set up as indicated in the steps below.

ZShut down the computers to be protected by the UPS.

Connect the UPS to a wall outlet. (For UPSs above 3kVA, please refer to the UPS installation manual)

ZConnect the power cord of each computer to an outlet on the UPS. (For UPSs above 3kVA, please refer to the UPS installation manual)

1.1.4.1 How to connect UPS / agent / network :

ZInsert the optional card in the UPS and connect the UPS to the computer network.

ZStart the MGE UPS, then the computers.

1.1.4.2 Setting up the protection

ZSet up the Network Management Card (see user manual).

ZInstall Network Shutdown Module on all machines that are to be protected by the UPS (supplied with UPS battery backup power).

The software components for each platform and the user manuals are supplied free-of-charge on the Solution- Pac 2 CD or are available for download on the www.mgeups.com Web site, in the “Download area” section”

1.2Presentation of the Network Management Cards (NMC)

MGE provides 2 different form factors for its Network Management Cards :

ZNMC Minislot for UPS systems like the Evolution, EXtreme C, Pulsar EX RT, Pulsar/Comet DX series.

ZNMC Transverse for UPS systems like the Galaxy 3000, Galaxy 5000, Galaxy PW, Pulsar and Comet EXtreme series. Other MGE UPS systems (3-phase Comet, Galaxy, EPS 6000) can be remotely managed

using the Network Management Link

.

The Network Management Cards acquire information on the operation status of the UPS systems and provide remote control of these systems by means of an ETHERNET network from any SNMP administration station or Web browser. They also supply alarms to the Network Shutdown Modules to trigger shutdown or other automatic actions for protected servers.

A simple html browser is used for supervision and configuration.

Network Management Cards are compatible with all MGE UPS SYSTEMS supervision / protection systems:

ZNetwork Shutdown Modules

ZEntreprise Power Manager

ZManagement-Pac 2

1.3Presentation of the Environment Sensor solution

The Environment Sensor solution comprises a box to be connected to the Card Settings port of the Network Management Cards:

Environment Sensor enables measurement of temperature and humidity around the UPS, consideration of external alarms via 2 dry contacts and notification of alarms according to pre-programmed thresholds.

T H E U N I N T E R R U P T I B L E P O W E R P R O V I D E R

Network Management Card – User Manual

34003676EN/GA

Page 6/69

Image 6
Contents E U N I N T E R R U P T I B L E P O W E R P R O V I D E R Table of Contents Network Management CardsMaintenance Software UPGRADE62 ConfigurationConfiguration VIA Telnet Configuration VIA SSH APPENDICES63 Tables of Alarms and EventsIntroduction MGE Network SolutionConnecting the UPS to the Network Network Management Card or ProxyMonitoring the UPSs over the network MGE supervisor Enterprise Power ManagerProtecting the computers / servers Network Shutdown moduleSetting up the protection Presentation of the Environment Sensor solutionHow to connect UPS / agent / network ConnectionCompatibility with the legacy Solution-Pac WAN offering Direct sending of E-mailSending text messages SMS Technical data 9/69 Basic configuration Installation and ConfigurationInstallation Environment SensorSupervision / Administration via a Web browser Optimising the performance of your browserUPS zone general information on the UPS UPSUPS properties UPS status zone essential informationBattery status zone On-line help 3 3-Phase display Normal input measurementsBattery measurements UPS ControlBy Pass measurements 17/69 UPS weekly schedule programming Shutdown parameters Important note20/69 Viewing the alarms Logs Measurements23/69 Event log System log Notification Email NotificationNotified events Mail message configuration see next Recipient ListEmail Message Settings SenderSubject 29/69 Configuration User Name and password by default are MgeupsNetwork Settings 32/69 System 34/69 Notified Applications Central Shutdown Configuration Access control 38/69 SSL Time Characteristics Status Configuration LogEnvironment Environment status Environment Settings Humidity4 Log Servers protection Set-up of the shutdown parametersShutdown criteria managed by the Management Card Controlled outlets Specific set-up for long autonomy installation 30 mnShutdown when backup time is less than Shutdown durationLoad shedding or sequential shutdown Sequential startupDifferent server and UPS shutdown sequences Main UPS outletProgrammable outlet 49/69 2.1 Main UPS outlet 2.2 Programmable outlet2.3 Programmable outlet 51/69 3.1 Main UPS outlet 3.2 Programmable outletNetwork 4 Off/On command Main outlet55/69 Configuring a set of cards with Mupgrade Configuration in local mode and via Telnet or SSHConfiguration in local mode Choice 1 Snmp agent configuration menu MgeupsChoice 3 Access control Choice 2 UPS parametersChoice 4 Restore default configuration Choice 5 Reset the cardConfiguration via Telnet Configuration via SSHPuTTY SSH Client Program 61/69 Card firmware upgrade using Mupgrade Windows MaintenanceSoftware upgrade Card software upgrade via Tftp Unix and WindowsAppendices Tables of alarms and eventsAlarm table UPS event tableUPS 65/69 System alarm table English FrenchGlossary Programmable outlet controlled outlet Subnet maskTelnet Trap Snmp UM-Client

66074, 66244, 66846 specifications

MGE UPS Systems, a renowned leader in the uninterruptible power supply (UPS) sector, offers a range of products designed to deliver reliable power protection for critical applications. Among their notable models are the MGE UPS Systems 66846, 66244, and 66074, each offering unique features, advanced technologies, and robust characteristics tailored for various operational needs.

The MGE UPS Systems 66846 is characterized by its high efficiency and modular design, making it suitable for a wide array of environments. This model incorporates advanced power management capabilities, which ensures that users benefit from enhanced energy savings while maintaining optimal performance. With a scalable architecture, the 66846 can adapt to evolving power requirements, providing users with the flexibility to expand their system as their needs grow. The model also includes intelligent battery management features that prolong battery life and enhance reliability.

Moving to the MGE UPS Systems 66244, this model stands out for its compact design and high power density. It is engineered to deliver superior electrical performance while occupying minimal space, making it an excellent choice for facilities with limited room for equipment. The 66244's advanced thermal management system ensures that the device operates efficiently under varying load conditions without overheating. Its intuitive user interface simplifies monitoring and managing the UPS, giving users real-time insights into operational status and alerts.

The MGE UPS Systems 66074 offers advanced features geared towards critical infrastructure in data centers and telecom applications. This model boasts high fault tolerance and redundancy mechanisms, ensuring continuous power delivery even in the event of component failure. The 66074 is equipped with cutting-edge digital signal processing technology, which enhances the performance and reliability of the power supply. Additionally, it supports various connectivity options, allowing for seamless integration with existing power management systems.

Across these models, MGE UPS Systems emphasize user-friendliness with intuitive control interfaces and remote monitoring capabilities. Furthermore, their commitment to sustainability is evident in the energy-efficient designs that reduce the overall carbon footprint of power management operations. Each unit is rigorously tested to adhere to international safety and performance standards, ensuring confidence in their reliability for critical applications. Overall, MGE UPS Systems 66846, 66244, and 66074 represent a blend of innovation, efficiency, and dependability in the UPS market, making them ideal choices for businesses looking to safeguard their operations against power interruptions.