MGE UPS Systems 66846, 66244, 66074 user manual Direct sending of E-mail, Sending text messages SMS

Page 7

www.mgeups.com

Network

Management Cards

User Manual

1.4Direct sending of E-mail

When a UPS event occurs, the Network Management Card can directly notify up to 4 intranet or extranet addressees by e-mail (see Email Notification and Email Message Settings).

1.5Sending text messages (SMS)

SMS messages can be sent by specific configuration of the e-mail function via the internet access providers making the e-mail / SMS transfer.

1.6Compatibility with the Network Management Systems (NMS) – Trap sending

The Network Management Cards are compatible with the major Network Management Systems (IBM Tivoli, CA Unicenter, HP Insight Manager ..),. The Management-Pac 2 offering includes the necessary SNMP plug-in to allows an easy integration in the NMS. Events are notified by SNMP trap

ZNMS can subscribe on page “Notified Application

ZSNMP sequences are described in chapter “Server protection”

The trap list can be looked over in the document “Agent's MIB description” available on mgeups.com

1.7Compatibility with the legacy Solution-Pac WAN offering

Network Management Card is compatible with the legacy protection module UM-Clientand since the FA release also with the updated protection module Network Shutdown Module . It is possible to use the both modules on the same card, therefore, MGEUPS recommends to use the Network Shutdown Module on new installations.

T H E U N I N T E R R U P T I B L E P O W E R P R O V I D E R

Network Management Card – User Manual

34003676EN/GA

Page 7/69

Image 7
Contents E U N I N T E R R U P T I B L E P O W E R P R O V I D E R Network Management Cards Table of ContentsAPPENDICES63 Tables of Alarms and Events ConfigurationConfiguration VIA Telnet Configuration VIA SSH Maintenance Software UPGRADE62Network Management Card or Proxy MGE Network SolutionConnecting the UPS to the Network IntroductionNetwork Shutdown module MGE supervisor Enterprise Power ManagerProtecting the computers / servers Monitoring the UPSs over the networkConnection Presentation of the Environment Sensor solutionHow to connect UPS / agent / network Setting up the protectionDirect sending of E-mail Compatibility with the legacy Solution-Pac WAN offeringSending text messages SMS Technical data 9/69 Environment Sensor Installation and ConfigurationInstallation Basic configurationOptimising the performance of your browser Supervision / Administration via a Web browserUPS status zone essential information UPSUPS properties UPS zone general information on the UPSBattery status zone On-line help Normal input measurements 3 3-Phase displayUPS Control Battery measurementsBy Pass measurements 17/69 UPS weekly schedule programming Important note Shutdown parameters20/69 Viewing the alarms Measurements Logs23/69 Event log System log Email Notification NotificationNotified events Recipient List Mail message configuration see nextSender Email Message SettingsSubject 29/69 User Name and password by default are Mgeups ConfigurationNetwork Settings 32/69 System 34/69 Notified Applications Central Shutdown Configuration Access control 38/69 SSL Time Status Configuration Log CharacteristicsEnvironment Environment status Humidity Environment Settings4 Log Set-up of the shutdown parameters Servers protectionShutdown criteria managed by the Management Card Shutdown duration Specific set-up for long autonomy installation 30 mnShutdown when backup time is less than Controlled outletsSequential startup Load shedding or sequential shutdownMain UPS outlet Different server and UPS shutdown sequencesProgrammable outlet 49/69 2.2 Programmable outlet 2.1 Main UPS outlet2.3 Programmable outlet 51/69 3.2 Programmable outlet 3.1 Main UPS outletNetwork Main outlet 4 Off/On command55/69 Configuration in local mode and via Telnet or SSH Configuring a set of cards with MupgradeConfiguration in local mode Mgeups Choice 1 Snmp agent configuration menuChoice 2 UPS parameters Choice 3 Access controlChoice 5 Reset the card Choice 4 Restore default configurationConfiguration via SSH Configuration via TelnetPuTTY SSH Client Program 61/69 Card software upgrade via Tftp Unix and Windows MaintenanceSoftware upgrade Card firmware upgrade using Mupgrade WindowsUPS event table Tables of alarms and eventsAlarm table AppendicesUPS 65/69 English French System alarm tableGlossary Subnet mask Programmable outlet controlled outletTelnet UM-Client Trap Snmp

66074, 66244, 66846 specifications

MGE UPS Systems, a renowned leader in the uninterruptible power supply (UPS) sector, offers a range of products designed to deliver reliable power protection for critical applications. Among their notable models are the MGE UPS Systems 66846, 66244, and 66074, each offering unique features, advanced technologies, and robust characteristics tailored for various operational needs.

The MGE UPS Systems 66846 is characterized by its high efficiency and modular design, making it suitable for a wide array of environments. This model incorporates advanced power management capabilities, which ensures that users benefit from enhanced energy savings while maintaining optimal performance. With a scalable architecture, the 66846 can adapt to evolving power requirements, providing users with the flexibility to expand their system as their needs grow. The model also includes intelligent battery management features that prolong battery life and enhance reliability.

Moving to the MGE UPS Systems 66244, this model stands out for its compact design and high power density. It is engineered to deliver superior electrical performance while occupying minimal space, making it an excellent choice for facilities with limited room for equipment. The 66244's advanced thermal management system ensures that the device operates efficiently under varying load conditions without overheating. Its intuitive user interface simplifies monitoring and managing the UPS, giving users real-time insights into operational status and alerts.

The MGE UPS Systems 66074 offers advanced features geared towards critical infrastructure in data centers and telecom applications. This model boasts high fault tolerance and redundancy mechanisms, ensuring continuous power delivery even in the event of component failure. The 66074 is equipped with cutting-edge digital signal processing technology, which enhances the performance and reliability of the power supply. Additionally, it supports various connectivity options, allowing for seamless integration with existing power management systems.

Across these models, MGE UPS Systems emphasize user-friendliness with intuitive control interfaces and remote monitoring capabilities. Furthermore, their commitment to sustainability is evident in the energy-efficient designs that reduce the overall carbon footprint of power management operations. Each unit is rigorously tested to adhere to international safety and performance standards, ensuring confidence in their reliability for critical applications. Overall, MGE UPS Systems 66846, 66244, and 66074 represent a blend of innovation, efficiency, and dependability in the UPS market, making them ideal choices for businesses looking to safeguard their operations against power interruptions.