 | DTR toggle | 
| 
 | &D2 | Modem hangs up, returns to the | 
| 
 | 
 | Command Mode after DTR toggle | 
| 
 | &D3 | Resets modem after DTR toggle | 
| &F_ | &F | Recall factory default configuration | 
| &G_ | &G0 | Guard tone disabled | 
| 
 | &G1 | 550 Hz guard tone | 
| 
 | &G2 | 1800 Hz guard tone | 
| &K_ | &K0 | Disable flow control | 
| 
 | &K3 | Enable RTS/CTS hardware flow | 
| 
 | 
 | control | 
| 
 | &K4 | Enable XON/XOFF software flow control | 
| &L_ | &L0 | Modem is set up for  | 
| &M_ | &M0 | Asynchronous operation | 
| &S_ | &S0 | Force DSR Signal High (ON) | 
| 
 | &S1 | DSR off in command mode, on in  | 
| 
 | 
 | mode | 
| &T_ | &T0 | Ends test in progress | 
| 
 | &T1 | Perform Local Analog Loopback Test | 
| 
 | &T3 | Perform Local Digital Loopback Test | 
| 
 | &T6 | Perform a Remote Digital Loopback Test | 
| &V | &V0 | Displays Active Profile | 
| &W_ | &W0 | Stores the active profile as Profile 0 | 
| 
 | &W1 | Stores the active profile as Profile 1 | 
| &Y_ | &Y0 | Configuration Profile 0 active upon | 
| 
 | 
 | Power on or reset | 
| &Zn=x | Store phone number x into  | |
| 
 | 
 | RAM | 
| %E_ | %E0 | Disable  | 
| 
 | %E1 | Enable  | 
| %X_ | %X0 | Disable  | 
| 
 | %X1 | Enables  | 
| #CID=n | n=0 | Disable Caller ID | 
| 
 | n=1 | Enables Caller ID with formatting (date, | 
| 
 | 
 | time, number, name) | 
| 
 | n=2 | Enables Caller ID without formatting | 
| #CID? | 
 | Displays current Caller ID mode | 
| #CID=? | 
 | Returns Caller ID capabilities of modem. | 
| 3.5 | MNP/V.42/V.42bis Commands | 
| %C_ | %C0 Disable MNP Class 5 and V.42bis data | 
10