RS-232 SERIAL COMMANDS
MCommand
The M command displays the current routing status of the matrix.
Syntax:
m
Parameters:
None
Fiber Optic Extender Status F0 Command
The F0 command returns the state of pin 18 on the HDMI inputs.
Syntax:
f
Parameters:
None
Notes:
“High” is returned if +5V is present on HDMI input. “Low” is returned if +0V is
present on HDMI input. Setting param1 to a value of 0 will return the state of pin 18 on all HDMI inputs.
Using parameters with the F Command
Permits disabling / enabling of +5V for Fiber Optic Extenders.
Syntax:
f param1 param2
Parameters: |
|
|
|
|
|
|
param1 | HDMI input | [1 - 4] | ||||
param2 | State | [0 - 1] | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Value | Meaning | ||||
| 0 |
| Disable | |||
| 1 |
| Enable |
23